We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice
Sale!

Prime Absorbable Monofilament Polydioxanone (PDO/PDS) Suture · 3/8 Circle Taperpoint Conical Point Needle DR17 (17 mm) · USP 3/0 · Violet · 75 cm · Box of 12 units · Ref. P412DR1730

Original price was: 58,77 €.Current price is: 53,60 €.

Prime-quality absorbable monofilament polydioxanone (PDO/PDS) suture with a ⅜ circle needle, cylindrical body and 17 mm Taperpoint conical point (DR17), USP gauge 3/0 (metric 2) and 75 cm violet thread. Predictable absorption by hydrolysis between 180 and 210 days, with tensile strength retention of 75% at 2 weeks, 60-70% at 4 weeks and 45% at 8 weeks. Sterilised by ethylene oxide, single-use, with minimal tissue reaction and excellent knot security; indicated for soft tissue approximation, ligatures, general surgery, paediatric cardiovascular tissues and ophthalmology. Factory ref. P412DR1730 · SKU AMP412DR1730 · Presentation: box of 12 sterile units.

Se fabrica bajo pedido: el fabricante exige un mínimo de 10 unidades por referencia.

International shipping. Import duties and taxes are payable by the recipient.

Reference
AMP412DR1730

Description

1. Commercial Introduction

The absorbable monofilament polydioxanone (PDO/PDS) suture in Prime quality, factory reference P412DR1730, is the reference technical choice when the tissue needs prolonged support during healing and fully predictable reabsorption. This presentation combines a high-visibility violet thread of 75 cm in USP 3/0 gauge with a ⅜ circle needle, cylindrical body and 17 mm Taperpoint conical point (DR17), an atraumatic geometry designed for soft and well-perfused tissues.

Available in a box of 12 sterile units with batch traceability, it is a reliable and cost-effective solution for general surgery departments, paediatric cardiovascular surgery operating theatres, ophthalmology units and hospital purchasing centres seeking quality homogeneity with CE marking and competitive B2B conditions.

2. Technical Explanation

Polydioxanone is an absorbable synthetic polyester —a polymer of poly(p-dioxanone)— that degrades by hydrolysis, a mechanism independent of the patient’s enzymatic activity that guarantees a highly reproducible absorption kinetics between individuals. Being a monofilament, the thread has no wicking effect or capillarity: it reduces bacterial adherence, facilitates sliding through tissue and minimises the inflammatory response compared with braided multifilament sutures. Its firm feel and excellent knotting capacity make it suitable for ligatures and sutures of planes subjected to sustained tension during the critical healing phase.

The ⅜ circle needle with cylindrical body and Taperpoint conical point penetrates the tissue by separating the fibres without cutting them, which minimises tissue damage and makes it especially suitable for well-perfused soft tissues, vessels, peritoneum, parenchyma, paediatric cardiovascular tissue and ophthalmic procedures. The USP 3/0 gauge (metric 2) offers an optimal balance between strength and delicacy. The grooved violet colour improves the visibility of the thread on the surgical field and knot security. It is supplied sterile by ethylene oxide, single-use and cannot be re-sterilised.

3. Technical Specifications

3.1. Technical data sheet for reference P412DR1730

Parameter Specification
Factory reference P412DR1730
Reference Cahnos (SKU) AMP412DR1730
Quality / Brand Prime
Material Polydioxanone (PDO/PDS), polymer of poly(p-dioxanone)
Thread structure Synthetic grooved monofilament (not braided)
Gauge / size USP 3/0 (metric 2)
Thread length 75 cm
Thread colour Violet (high visibility)
Needle shape 3/8 circle (approx. 135°)
Needle body and point Cylindrical body, Taperpoint conical tip, atraumatic
Needle size DR17 – 17 mm
Swaged 1 needle per pack (single strand)
Absorption mechanism Hydrolysis (180-210 days)
Sterilisation Ethylene oxide (EO), sterile, single-use, not re-sterilisable
Tissue reaction Minimal, with excellent tensile strength and knot tying
Indications Approximation of soft tissues, ligatures, general surgery, paediatric cardiovascular tissues and ophthalmology
Presentation Box of 12 sterile units

3.2. Tensile strength retention profile

Period after implantation Tensile strength retention
2 weeks 75 %
4 weeks 60-70 %
8 weeks 45 %
Complete absorption 180-210 days by hydrolysis

This prolonged force retention profile is maintained during the critical healing phase of slow-healing tissues, so its use is recommended in closures of fascia, aponeurosis and structures subjected to sustained traction.

4. Equivalences and Cross-References

Polydioxanone monofilament is the material basis of the market reference lines for long-lasting absorbable sutures (PDS-type family). On the verified configuration of this data sheet (⅜ circle cylindrical needle with conical point of 17 mm, USP 3/0 gauge, violet thread of 75 cm), the following commercial references from other manufacturers have been compared in primary sources:

Manufacturer / Brand Family / Model Reference code / SKU Equivalence level Technical differences / Remarks
Ethicon (Johnson & Johnson MedTech) PDS II – polydioxanone monofilament, USP 3/0, violet, RB-1 needle of ½ circle conical taper point of 17 mm Z305H Comparable by category (not interchangeable 1:1) Verified in the official Ethicon catalogue (EPC) and authorised distributors: they match in PDO monofilament polymer, USP 3/0 gauge, violet colour, needle size (17 mm) and conical point; they differ in curvature (½ circle vs ⅜ circle), thread length (70 cm vs 75 cm) and presentation (box of 36 units vs 12 units).
Ethicon (Johnson & Johnson MedTech) PDS II – polydioxanone monofilament, USP 3/0, violet, SH needle of ½ circle conical point of 26 mm Z316H Comparable by category (not interchangeable 1:1) Verified in the official Ethicon data sheet: same PDO monofilament polymer, same USP 3/0 gauge and violet colour; they differ in curvature (½ circle), needle size (26 mm vs 17 mm) and thread length (70 cm vs 75 cm).

There is no equivalence table validated by the manufacturer that officially cross-references this exact configuration (⅜ circle needle with conical point of 17 mm, USP 3/0, violet, 75 cm) with the commercial series of other brands as interchangeable 1:1; consult the technical department before use in tenders. As homologous market families to be verified code by code in their official technical data sheet before any substitution, the following are cited: the PDS II and PDS Plus lines from Ethicon (the latter with antibacterial triclosan coating, indicated only where its use is approved), the MonoPlus line from B. Braun/Aesculap (violet polydioxanone monofilament), the Surgicryl PDO line from SMI and the Maxon line from Medtronic/Covidien (made of polyglyconate, a different polymer, which must be verified in its absorption profile). All must be checked field by field in their official data sheet: USP gauge, thread length, colour, curvature, body, point and needle size, as well as the attachment. The brands cited belong to their respective manufacturers and are mentioned only as comparative reference.

5. Selection tips and variants of interest

When choosing a PDO suture, always verify the USP gauge according to the tissue plane: fine gauges (4/0 to 6/0) for skin and subcutaneous tissue, 3/0 and 2/0 for general soft tissue —as is the case with this reference— and USP 0 and above for fascia and planes under tension. The needle geometry is also decisive: the Taperpoint conical point (DR/HR) is reserved for delicate and well-perfused tissues (vessels, parenchyma, paediatric cardiovascular), the trocar point (DRT/HRT) for firmer tissues and the reverse cutting triangular point (DS/HS) for fibrous tissues such as skin and aponeurosis.

Within the Cahnos catalogue, the PDO/PDS Prime family of ⅜ circle with taper point includes variants of interest:

Reference (SKU) Recommended variant
AMP412DR1940 PDO Prime, DR19 needle with conical point of 19 mm, USP 4/0, violet, 75 cm (fine gauge for skin and subcutaneous tissue)
AMP412DR2010 PDO Prime, DR20 needle with conical point of 20 mm, USP 0, violet, 75 cm (higher strength for planes under tension)
AMP412HR3030 PDO Prime, ½ circle HR30 needle with conical point, USP 3/0, violet, 75 cm (greater penetration arc, deep fields)
AMP418DR1730-2 PDO Prime, double needle 2×DR17 with conical point, USP 3/0, violet, 70 cm (continuous suture with anchoring at both ends)
AMP412DS1930 PDO Prime, 3/8 circle reverse cutting triangular needle DS19, USP 3/0, violet, 75 cm (for fibrous tissues with the same gauge)

As this is sterile single-use material, check the integrity of the packaging before each procedure, respect the expiry date and keep the suture in a cool, dry place, protected from sunlight, together with the batch number for traceability in the operating theatre. For special B2B conditions, volume orders or other gauges, lengths and colours made to order, contact the technical-commercial team at Cahnos.

Additional information

Material

Polydioxanone (PDO/PDS), poly(p-dioxanone) polymer, synthetic grooved monofilament

Gauge

USP 3/0 (metric 2)

Thread colour

Violet (high visibility)

Needle shape

3/8 circle (approx. 135°)

Needle point type

Conical Taperpoint (cylindrical body, atraumatic)

Needle size

17 mm (DR17)

Swaged

1 needle per pack (single strand)

Sterilisation

Ethylene oxide (EO), single-use, not for re-sterilisation

Tissue reaction

Minimal

Presentation

Box of 12 sterile units

Manufacturer reference

P412DR1730

Indications

Approximation of soft tissues, ligatures, general surgery, paediatric cardiovascular tissues and ophthalmology

Regulatory standard

USP/EP, CE marking

Medida de aguja

DR 17

Usp

3/0

Color

Violet

Medida de hilo

75 cm

Tipo de aguja

Cylindrical

Forma de aguja

3/8 circle

Calidad sutura

Prime

Absorcion

Slow absorbable (> 120 days)

Reviews

There are no reviews yet.

Be the first to review “Prime Absorbable Monofilament Polydioxanone (PDO/PDS) Suture · 3/8 Circle Taperpoint Conical Point Needle DR17 (17 mm) · USP 3/0 · Violet · 75 cm · Box of 12 units · Ref. P412DR1730”

Your email address will not be published. Required fields are marked *