We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice
Sale!

Absorbable Monofilament Polydioxanone PDO/PDS Suture Prime 4/0 – 3/8 Circle Cylindrical Conical Point Needle 19 mm (DR19) – Violet Thread 75 cm – Box of 12 units · Ref. AMP412DR1940

Original price was: 51,86 €.Current price is: 41,70 €.

Prime quality absorbable monofilament polydioxanone (PDO/PDS) suture, with an atraumatic needle of ⅜ circle, cylindrical body and conical point (taperpoint) of 19 mm (DR19), USP gauge 4/0 (metric 1.5) and high-visibility violet thread with a length of 75 cm. Predictable absorption by hydrolysis in 180–210 days, with tensile strength retention of 75 % at 2 weeks, 60–70 % at 4 and 45 % at 8. Sterile by ethylene oxide, single-use and with minimal tissue reaction; indicated for approximation of soft tissues, ligatures, general surgery, paediatric cardiovascular tissue and ophthalmology. Presentation in a box of 12 sterile units, with B2B conditions for hospitals and purchasing centres. Factory reference P412DR1940.

International shipping. Import duties and taxes are payable by the recipient.

Reference
AMP412DR1940

Description

1. Product Presentation

The absorbable monofilament polydioxanone (PDO/PDS) suture from the Prime line is the reference technical choice when the tissue needs prolonged support during healing and fully predictable reabsorption. This presentation combines a violet thread of 75 cm in USP 4/0 gauge with a ⅜ circle needle, cylindrical body and conical point (taperpoint) of 19 mm (DR19), designed to pass through soft, well-perfused tissues with the least possible trauma.

Available in a box of 12 sterile units with CE marking, it is a reliable and cost-effective solution for general surgery departments, paediatric cardiovascular surgery operating theatres, ophthalmology units and hospital purchasing centres seeking quality consistency and full traceability in each package.

2. Technical Explanation

Polydioxanone is an absorbable synthetic polyester —a poly(p-dioxanone) polymer— that degrades by hydrolysis, a mechanism independent of the patient’s enzymatic activity that guarantees a highly reproducible absorption kinetics between individuals. Being a monofilament, the thread has no wicking effect or capillarity: it reduces bacterial adherence, facilitates sliding through tissue and minimises the inflammatory response compared to multifilaments. Its firm feel and excellent knotting capacity make it suitable for ligatures and sutures of planes subjected to sustained tension during the critical healing phase.

The ⅜ circle needle with cylindrical body and conical point (taperpoint) separates and displaces tissue fibres without cutting effect, being especially atraumatic in delicate, well-perfused structures such as vessels, parenchyma, paediatric cardiovascular tissue and ocular tissue. The USP 4/0 gauge (metric 1.5) offers an optimal balance between strength and delicacy for skin, subcutaneous tissue and soft planes. The violet colour improves thread visibility on the surgical field. It is supplied sterile by ethylene oxide, single-use and cannot be re-sterilised.

3. Technical Specifications

3.1. General characteristics

Specification Detail
Material Polydioxanone (PDO/PDS), absorbable synthetic monofilament polymer
Thread structure Fluted monofilament (not braided)
Gauge USP 4/0 (metric 1.5)
Thread length 75 cm
Thread colour Violet (high surgical visibility)
Swaged 1 needle per suture
Needle shape ⅜ circle
Needle body and point Cylindrical, conical point (taperpoint / atraumatic)
Needle size DR19 – 19 mm
Absorption mechanism Hydrolysis; complete absorption between 180 and 210 days
Sterilisation Ethylene oxide (EO); single-use, not re-sterilisable
Tissue reaction Minimal, with excellent tensile strength and knot tying
Indications Approximation of soft tissues, ligatures, general surgery, paediatric cardiovascular tissues and ophthalmology
Presentation Box of 12 sterile units
Factory reference / SKU P412DR1940 / AMP412DR1940

3.2. Tensile strength retention profile

Period after implantation Tensile strength retention
2 weeks 75 %
4 weeks 60–70 %
8 weeks 45 %
Complete absorption 180–210 days by hydrolysis, with minimal tissue reaction

This prolonged force retention profile is maintained during the critical healing phase of slow-healing tissues, so its use is recommended in closures of planes subjected to sustained traction and in procedures requiring prolonged support.

4. Equivalences and Cross-References

Monofilament polydioxanone is the material basis of the market reference lines for long-lasting absorbable sutures (PDS-type family). Based on the verified configuration of this data sheet (⅜ circle cylindrical needle with conical point of 19 mm, USP 4/0 gauge, violet thread of 75 cm), the following commercial reference from another manufacturer has been compared in official catalogue and authorised distributors:

Manufacturer / Brand Family / Model Code / SKU Equivalence level Technical differences / Remarks
Johnson & Johnson MedTech (Ethicon) PDS II® (polydioxanone) violet monofilament, PS-2 needle Z513G Comparable by category (not interchangeable 1:1) Same PDO monofilament polymer, same USP 4/0 gauge, same 19 mm needle in ⅜ circle and violet colour. Differences: reverse cutting point (PS-2, reverse cutting) versus the taperpoint conical point DR19 of this reference, and thread length of 45 cm versus 75 cm. Confirmed in Ethicon catalogue and authorised distributors.

There is no equivalence table validated by the manufacturer that officially cross-references this reference with the commercial series of other brands; consult the technical department before using in tenders. As homologous market families to verify code by code before substitution: the PDS II® and PDS Plus® lines from Ethicon (the latter with antibacterial triclosan coating, indicated only where its use is approved), the MonoPlus® line from B. Braun/Aesculap (violet polydioxanone monofilament, HR series needles), the Surgicryl® PDO line from SMI and the Maxon line from Medtronic/Covidien (made of polyglyconate, a different polymer, so its absorption profile must be verified). All must be checked in their official technical data sheet: USP gauge, thread length, colour, curvature, body, point and needle size. The cited brands belong to their respective manufacturers and are mentioned only as comparative reference.

5. Selection tips and variants of interest

When choosing a PDO suture, always verify the USP gauge according to the tissue plane: fine gauges (4/0 to 6/0) for skin, subcutaneous tissue and delicate tissues; 3/0 and 2/0 for general soft tissue; and USP 0 and above for fascia and planes under tension. Needle geometry is also decisive: the conical point (DR/HR) is indicated for delicate, well-perfused tissues (vessels, parenchyma, paediatric cardiovascular), while the trocar point (DRT/HRT) is reserved for firmer tissues and the reverse cutting triangular point (DS/HS) for fibrous tissues such as skin and aponeurosis.

Within the Cahnos catalogue, the PDO/PDS family includes variants of interest: the AMP412DS1940 (⅜ circle reverse cutting triangular needle of 19 mm, USP 4/0, 75 cm) for fibrous tissues; the AM412HR1740 (½ circle cylindrical needle with conical point of 17 mm, USP 4/0, 75 cm) for deeper fields; and the AMP418HRP2240-2 (double ½ circle conical point needle, USP 4/0, 70 cm) for continuous sutures and anastomoses. Always verify the USP gauge, size and geometry of the needle against your surgical protocol before substituting one reference for another.

As it is sterile single-use material, check the integrity of the packaging before each procedure, respect the expiry date and store the suture in a cool, dry place, protected from sunlight. For special B2B conditions, volume orders or other gauges, lengths and colours on request, contact the technical-commercial team at Cahnos.

Additional information

Material

Polydioxanone (PDO/PDS) grooved monofilament

USP size

4/0 (metric 1.5)

Needle type

Cylindrical body, taper point (Taperpoint)

Needle size

DR19 – 19 mm, 1 needle

Sterilisation

Ethylene oxide (EO), single-use

Presentation

Box of 12 sterile units

Manufacturer reference

P412DR1940

Medida de aguja

DR 19

Usp

4/0

Color

Violet

Medida de hilo

75 cm

Tipo de aguja

Cylindrical

Forma de aguja

3/8 circle

Calidad sutura

Prime

Absorcion

Slow absorbable (> 120 days)

Reviews

There are no reviews yet.

Be the first to review “Absorbable Monofilament Polydioxanone PDO/PDS Suture Prime 4/0 – 3/8 Circle Cylindrical Conical Point Needle 19 mm (DR19) – Violet Thread 75 cm – Box of 12 units · Ref. AMP412DR1940”

Your email address will not be published. Required fields are marked *