We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice
Sale!

Polydioxanone (PDO/PDS) Prime Absorbable Monofilament Suture · 3/8 Circle Triangular Reverse Cutting Needle DS19 (19 mm) · USP 5/0 · Violet Thread 45 cm · Box of 12 units · Ref. P411DS1950

Original price was: 64,90 €.Current price is: 43,50 €.

Absorbable monofilament suture of Polydioxanone (PDO/PDS) Prime with a 3/8 circle needle, triangular body and reverse cutting point, 19 mm (DS19), USP gauge 5/0 and 45 cm violet thread. Predictable absorption by hydrolysis in 180–210 days, with tensile strength retention of 75% at 2 weeks, 60–70% at 4 weeks and 45% at 8 weeks: prolonged support for slow-healing tissues. Sterilised by ethylene oxide, single-use and with minimal tissue reaction; indicated for tissue approximation, ligatures, general surgery, paediatric cardiovascular tissues and ophthalmology. Manufacturer reference P411DS1950 · SKU AMP411DS1950 · supplied in a box of 12 units.

Se fabrica bajo pedido: el fabricante exige un mínimo de 30 unidades por referencia.

International shipping. Import duties and taxes are payable by the recipient.

Reference
AMP411DS1950

Description

1. Product Presentation

The absorbable monofilament Polydioxanone (PDO/PDS) Prime suture, manufacturer reference P411DS1950, is the technical choice when the tissue needs prolonged support during healing with fully predictable reabsorption. This presentation combines a 45 cm violet thread in USP 5/0 gauge with a ⅜ circle needle, reverse cutting triangular body and point of 19 mm (DS19), a geometry designed to penetrate firm and fibrous tissues with minimal drag and excellent tip control.

Available in a box of 12 units, it is a reliable and cost-effective solution for general surgery departments, paediatric cardiovascular surgery operating theatres, ophthalmology units and hospital purchasing centres seeking quality homogeneity with CE marking and gauges conforming to USP/European Pharmacopoeia.

2. Technical Explanation

Polydioxanone is a synthetic absorbable polyester —a polymer of poly(p-dioxanone)— that degrades by hydrolysis, a mechanism independent of the patient’s enzymatic activity that guarantees a highly reproducible absorption kinetics, completing between 180 and 210 days. Being a monofilament, the thread has no wicking effect or capillarity: it reduces bacterial adherence, facilitates sliding through tissue and minimises the inflammatory response compared with multifilament threads. Its firm feel and excellent knotting capacity make it suitable for ligatures and sutures of planes subjected to sustained tension during the critical healing phase.

The ⅜ circle needle (approximate curvature of 135°) with reverse cutting triangular body and point (reverse cutting) has the cutting edge oriented towards the outer face of the curve, allowing penetration of resistant tissues —skin, dermis, mucosa and fibrous planes— with a lower risk of tearing and a stable suture channel. The USP 5/0 gauge (metric 1) provides an optimal balance between strength and delicacy for subcutaneous tissue, fine skin and paediatric surgery. The high-visibility violet colour improves the contrast of the thread on the surgical field. It is supplied sterile by ethylene oxide, single-use and cannot be re-sterilised.

3. Technical Specifications

3.1. General characteristics

Property Specification
Material Polydioxanone (PDO/PDS), absorbable synthetic monofilament polymer
Thread structure Fluted monofilament (not braided)
Quality / range Prime (P411DS series)
Gauge / size USP 5/0 (metric 1) · conforming to USP / European Pharmacopoeia
Thread length 45 cm (1 strand per unit)
Thread colour High-visibility violet, fluted
Needle shape 3/8 circle (approx. 135°)
Needle body and point Triangular, reverse cutting (reverse cutting), body and point
Needle size DS19 – 19 mm (Prime)
Swaged 1 needle per suture
Absorption mechanism Hydrolysis (180–210 days)
Sterilisation Ethylene oxide (EO) — sterile, single-use, non-resterilisable
Tissue reaction Minimal, with excellent tensile strength and knot tying
Indications Tissue approximation, ligatures, general surgery, paediatric cardiovascular tissues and ophthalmology
Presentation Box of 12 sterile units (individual pouches)
Factory reference / SKU P411DS1950 / AMP411DS1950

3.2. Tensile strength retention profile

Time after implantation Tensile strength retention
2 weeks 75 %
4 weeks 60–70 %
8 weeks 45 %
Complete absorption 180–210 days by hydrolysis

This prolonged strength retention profile is maintained during the critical healing phase of slow-healing tissues, so its use is recommended in closures of fascia, aponeurosis, skin and structures subjected to sustained traction.

3.3. Size equivalence

USP size Metric size Approximate diameter
5/0 1 (EP) 0.10 – 0.149 mm (USP/EP)

4. Equivalences and Cross-References

Monofilament polydioxanone is the material basis of the market reference lines for long-acting absorbable sutures (PDS-type family). For the verified configuration of this technical data sheet (⅜ circle needle, reverse cutting triangular body and point of 19 mm, USP 5/0 gauge, 45 cm violet thread), no reference from another manufacturer has been found in public sources that matches field by field (material, gauge, ⅜ curvature, reverse cutting point family, 19 mm size, 45 cm length and colour), so it is not possible to declare an exact reference equivalence verified with third parties.

There is no equivalence table validated by the manufacturer for this specific configuration; consult the Cahnos technical department before use in tenders. As homologous market families, to be verified code by code in their official technical data sheet before any substitution, the following are cited: the PDS II® and PDS Plus® line from Ethicon (the latter with antibacterial triclosan coating, indicated only where its use is approved), the MonoPlus® line from B. Braun/Aesculap (polydioxanone monofilament), the Surgicryl PDO line from SMI and the Maxon line from Medtronic/Covidien (made of polyglyconate, a different polymer, so its absorption profile must be verified). All must be checked field by field in their official data sheet: USP gauge, thread length, colour, curvature, body, point and needle size, as well as the attachment. The cited brands belong to their respective manufacturers and are mentioned only as comparative reference.

Within the PDO/PDS range system of Cahnos itself, the reference AM411DS1950 (Ref. 411DS1950) in Normal quality constitutes the direct configuration equivalence (same DS19 needle, USP 5/0, 45 cm violet thread), making it the natural cost alternative without variation in dimensional performance.

5. Selection tips and variants of interest

When choosing a PDO suture, always verify the USP gauge according to the tissue plane: fine gauges (4/0 to 6/0) for skin, subcutaneous tissue and delicate tissues —as is the case with this reference—, 3/0 and 2/0 for general soft tissue and USP 0 and above for fascia and planes under tension. The needle geometry is also decisive: the reverse cutting triangular point (DS series) is indicated for fibrous and resistant tissues with controlled penetration, while the conical point (HR) is reserved for delicate and well-perfused tissues (vessels, parenchyma) and the trocar point (DRT) for tissues of intermediate consistency.

Within the Cahnos catalogue, the PDO/PDS family of ⅜ circle with reverse cutting includes variants of interest: AMP411DS1250 (DS12 needle, USP 5/0, 45 cm) for smaller surgical fields; AMP411XDS1350 and AMP411XDS1650 (XDS 13 and XDS 16 mm precision needles with square body, USP 5/0, 45 cm) for precision and aesthetic surgery; AMP411DS1940FN (same DS19 fine needle, USP 4/0, 45 cm) for slightly larger gauges; AMP412DS1930 (DS19 needle, USP 3/0, 75 cm) for planes of greater consistency; and AMP418DRT1350 (DRT13 trocar needle, USP 5/0, 70 cm) for firmer tissues. Always verify the USP gauge, needle size and geometry against your surgical protocol before substituting one reference for another.

As this is sterile single-use material, check the integrity of the packaging before each procedure, respect the expiry date and store the suture in a cool, dry place, protected from sunlight. For special B2B conditions, volume orders or other gauges, lengths and colours made to order, contact the technical-commercial team at Cahnos.

Additional information

Material

Polydioxanone (PDO/PDS), absorbable synthetic monofilament polymer

Thread structure

Fluted monofilament (not braided)

Quality

Prime (P411DS series)

USP size

5/0 (metric 1)

Thread diameter

0.10 – 0.149 mm (USP/EP)

Thread colour

High-visibility violet

Needle shape

3/8 circle (approx. 135°)

Needle type

Triangular reverse cutting (reverse cutting), body and point

Needle size

DS19 (19 mm) Prime

Swaged

1 needle per suture

Absorption mechanism

Hydrolysis (180–210 days)

Strength retention

75% (2 weeks), 60–70% (4 weeks), 45% (8 weeks)

Sterilisation

Ethylene oxide (EO), single-use, not re-sterilisable

Tissue reaction

Minimal

Indications

Tissue approximation, ligatures, general surgery, paediatric cardiovascular tissues and ophthalmology

Presentation

Box of 12 sterile units

Manufacturer reference

P411DS1950

Regulatory standard

USP / European Pharmacopoeia (EP metric sizes)

Medida de aguja

DS 19

Usp

5/0

Color

Violet

Medida de hilo

45 cm

Tipo de aguja

Reverse cutting

Forma de aguja

3/8 circle

Calidad sutura

Prime

Reviews

There are no reviews yet.

Be the first to review “Polydioxanone (PDO/PDS) Prime Absorbable Monofilament Suture · 3/8 Circle Triangular Reverse Cutting Needle DS19 (19 mm) · USP 5/0 · Violet Thread 45 cm · Box of 12 units · Ref. P411DS1950”

Your email address will not be published. Required fields are marked *