Description
1. Product Presentation
The absorbable monofilament Polydioxanone (PDO/PDS) Prime suture, manufacturer reference P411DS1950, is the technical choice when the tissue needs prolonged support during healing with fully predictable reabsorption. This presentation combines a 45 cm violet thread in USP 5/0 gauge with a ⅜ circle needle, reverse cutting triangular body and point of 19 mm (DS19), a geometry designed to penetrate firm and fibrous tissues with minimal drag and excellent tip control.
Available in a box of 12 units, it is a reliable and cost-effective solution for general surgery departments, paediatric cardiovascular surgery operating theatres, ophthalmology units and hospital purchasing centres seeking quality homogeneity with CE marking and gauges conforming to USP/European Pharmacopoeia.
2. Technical Explanation
Polydioxanone is a synthetic absorbable polyester —a polymer of poly(p-dioxanone)— that degrades by hydrolysis, a mechanism independent of the patient’s enzymatic activity that guarantees a highly reproducible absorption kinetics, completing between 180 and 210 days. Being a monofilament, the thread has no wicking effect or capillarity: it reduces bacterial adherence, facilitates sliding through tissue and minimises the inflammatory response compared with multifilament threads. Its firm feel and excellent knotting capacity make it suitable for ligatures and sutures of planes subjected to sustained tension during the critical healing phase.
The ⅜ circle needle (approximate curvature of 135°) with reverse cutting triangular body and point (reverse cutting) has the cutting edge oriented towards the outer face of the curve, allowing penetration of resistant tissues —skin, dermis, mucosa and fibrous planes— with a lower risk of tearing and a stable suture channel. The USP 5/0 gauge (metric 1) provides an optimal balance between strength and delicacy for subcutaneous tissue, fine skin and paediatric surgery. The high-visibility violet colour improves the contrast of the thread on the surgical field. It is supplied sterile by ethylene oxide, single-use and cannot be re-sterilised.
3. Technical Specifications
3.1. General characteristics
| Property | Specification |
| Material | Polydioxanone (PDO/PDS), absorbable synthetic monofilament polymer |
| Thread structure | Fluted monofilament (not braided) |
| Quality / range | Prime (P411DS series) |
| Gauge / size | USP 5/0 (metric 1) · conforming to USP / European Pharmacopoeia |
| Thread length | 45 cm (1 strand per unit) |
| Thread colour | High-visibility violet, fluted |
| Needle shape | 3/8 circle (approx. 135°) |
| Needle body and point | Triangular, reverse cutting (reverse cutting), body and point |
| Needle size | DS19 – 19 mm (Prime) |
| Swaged | 1 needle per suture |
| Absorption mechanism | Hydrolysis (180–210 days) |
| Sterilisation | Ethylene oxide (EO) — sterile, single-use, non-resterilisable |
| Tissue reaction | Minimal, with excellent tensile strength and knot tying |
| Indications | Tissue approximation, ligatures, general surgery, paediatric cardiovascular tissues and ophthalmology |
| Presentation | Box of 12 sterile units (individual pouches) |
| Factory reference / SKU | P411DS1950 / AMP411DS1950 |
3.2. Tensile strength retention profile
| Time after implantation | Tensile strength retention |
| 2 weeks | 75 % |
| 4 weeks | 60–70 % |
| 8 weeks | 45 % |
| Complete absorption | 180–210 days by hydrolysis |
This prolonged strength retention profile is maintained during the critical healing phase of slow-healing tissues, so its use is recommended in closures of fascia, aponeurosis, skin and structures subjected to sustained traction.
3.3. Size equivalence
| USP size | Metric size | Approximate diameter |
| 5/0 | 1 (EP) | 0.10 – 0.149 mm (USP/EP) |
4. Equivalences and Cross-References
Monofilament polydioxanone is the material basis of the market reference lines for long-acting absorbable sutures (PDS-type family). For the verified configuration of this technical data sheet (⅜ circle needle, reverse cutting triangular body and point of 19 mm, USP 5/0 gauge, 45 cm violet thread), no reference from another manufacturer has been found in public sources that matches field by field (material, gauge, ⅜ curvature, reverse cutting point family, 19 mm size, 45 cm length and colour), so it is not possible to declare an exact reference equivalence verified with third parties.
There is no equivalence table validated by the manufacturer for this specific configuration; consult the Cahnos technical department before use in tenders. As homologous market families, to be verified code by code in their official technical data sheet before any substitution, the following are cited: the PDS II® and PDS Plus® line from Ethicon (the latter with antibacterial triclosan coating, indicated only where its use is approved), the MonoPlus® line from B. Braun/Aesculap (polydioxanone monofilament), the Surgicryl PDO line from SMI and the Maxon line from Medtronic/Covidien (made of polyglyconate, a different polymer, so its absorption profile must be verified). All must be checked field by field in their official data sheet: USP gauge, thread length, colour, curvature, body, point and needle size, as well as the attachment. The cited brands belong to their respective manufacturers and are mentioned only as comparative reference.
Within the PDO/PDS range system of Cahnos itself, the reference AM411DS1950 (Ref. 411DS1950) in Normal quality constitutes the direct configuration equivalence (same DS19 needle, USP 5/0, 45 cm violet thread), making it the natural cost alternative without variation in dimensional performance.
5. Selection tips and variants of interest
When choosing a PDO suture, always verify the USP gauge according to the tissue plane: fine gauges (4/0 to 6/0) for skin, subcutaneous tissue and delicate tissues —as is the case with this reference—, 3/0 and 2/0 for general soft tissue and USP 0 and above for fascia and planes under tension. The needle geometry is also decisive: the reverse cutting triangular point (DS series) is indicated for fibrous and resistant tissues with controlled penetration, while the conical point (HR) is reserved for delicate and well-perfused tissues (vessels, parenchyma) and the trocar point (DRT) for tissues of intermediate consistency.
Within the Cahnos catalogue, the PDO/PDS family of ⅜ circle with reverse cutting includes variants of interest: AMP411DS1250 (DS12 needle, USP 5/0, 45 cm) for smaller surgical fields; AMP411XDS1350 and AMP411XDS1650 (XDS 13 and XDS 16 mm precision needles with square body, USP 5/0, 45 cm) for precision and aesthetic surgery; AMP411DS1940FN (same DS19 fine needle, USP 4/0, 45 cm) for slightly larger gauges; AMP412DS1930 (DS19 needle, USP 3/0, 75 cm) for planes of greater consistency; and AMP418DRT1350 (DRT13 trocar needle, USP 5/0, 70 cm) for firmer tissues. Always verify the USP gauge, needle size and geometry against your surgical protocol before substituting one reference for another.
As this is sterile single-use material, check the integrity of the packaging before each procedure, respect the expiry date and store the suture in a cool, dry place, protected from sunlight. For special B2B conditions, volume orders or other gauges, lengths and colours made to order, contact the technical-commercial team at Cahnos.





Reviews