Description
1. Product Presentation
The Prime line absorbable monofilament polydioxanone (PDO/PDS) suture is the reference technical choice when the tissue needs prolonged support during healing and fully predictable reabsorption. This presentation combines a 75 cm grooved violet thread in USP 0 gauge with a ⅜ circle needle, triangular body and reverse cutting point of 30 mm (DS30), a geometry designed to pass through fibrous tissue with a clean, controlled passage. Available in a box of 12 sterile units, it is a reliable and cost-effective solution for general surgery departments, paediatric cardiovascular surgery theatres, ophthalmology units and hospital purchasing centres.
2. Technical Explanation
Polydioxanone is an absorbable synthetic polyester —a poly(p-dioxanone) polymer— that degrades by hydrolysis, a mechanism independent of the patient’s enzymatic activity that ensures highly reproducible absorption kinetics between individuals. As a monofilament, the thread has no wicking effect or capillarity, which reduces bacterial adherence, facilitates passage through tissue and minimises the inflammatory response compared with multifilament sutures. Its firm feel and excellent knotting ability make it suitable for ligatures and sutures of tissue planes subjected to sustained tension during the critical healing phase.
The ⅜ circle needle with reverse cutting triangular point has the cutting edge on the outer side of the curve, which prevents tearing of superficial tissue and makes it especially suitable for skin, subcutaneous tissue, aponeuroses and other fibrous planes. With a length of 30 mm (DS30) and USP 0 gauge (metric 3.5), this configuration offers high tensile strength for planes under tension. The grooved violet colour improves thread visibility on the surgical field and knot security. It is supplied sterile by ethylene oxide, single-use and cannot be re-sterilised.
3. Technical Specifications
3.1. General characteristics
| Parameter | Specification |
| Material | Polydioxanone (PDO/PDS), absorbable synthetic monofilament polymer |
| Thread structure | Grooved monofilament |
| Quality | Prime |
| Gauge / size | USP 0 (metric 3.5) |
| Thread length | 75 cm |
| Thread colour | Violet (high visibility) |
| Needle shape | ⅜ circle |
| Needle body and point | Triangular, reverse cutting point, grooved |
| Needle size | DS30 – 30 mm |
| Swaged | 1 needle per pack (single strand) |
| Absorption mechanism | Hydrolysis (180–210 days) |
| Sterilisation | Ethylene oxide (single-use, not re-sterilisable) |
| Tissue reaction | Minimal, with excellent tensile strength and knot tying |
| Indications | Tissue approximation, ligatures, general surgery, fascia, paediatric cardiovascular tissues and ophthalmology |
| Presentation | Box of 12 sterile units (individual pack) |
| Factory reference / SKU | P412DS3010 / AMP412DS3010 |
3.2. Tensile strength retention profile
| Time | Tensile strength retention |
| 2 weeks | 75 % |
| 4 weeks | 60–70 % |
| 8 weeks | 45 % |
| Complete absorption | 180–210 days by hydrolysis |
This prolonged strength retention profile is maintained during the critical healing phase of slow-healing tissues, and its use is therefore recommended in closures of fascia, aponeuroses and structures subjected to sustained tension.
4. Equivalences and Cross-References
Monofilament polydioxanone is the material basis of the market reference lines for long-lasting absorbable sutures (PDS-type family). Against the verified configuration of this technical data sheet (⅜ circle reverse cutting triangular needle of 30 mm, USP 0 gauge, 75 cm violet thread), the following commercial reference from another manufacturer has been cross-checked in primary sources:
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
| Ethicon (Johnson & Johnson MedTech) | PDS II® (polydioxanone) violet monofilament, USP 0 gauge | Z970H | Comparable by category (not interchangeable 1:1) | Same PDO monofilament material and same USP 0 gauge, confirmed in the GUDID/FDA regulatory database and authorised distributors. They differ: CP-2 ½ circle needle with reverse cutting point of 26 mm versus the ⅜ circle DS30 needle of 30 mm of this reference, and thread length of 70 cm versus 75 cm (single thread). |
There is no equivalence table validated by the manufacturer that officially cross-references this product with the commercial ranges of other brands; consult the technical department before use in tenders. As homologous market families to be verified code by code before substitution: the PDS II® and PDS Plus® lines from Ethicon (the latter with antibacterial triclosan coating, indicated only where its use is approved), the MonoPlus® line from B. Braun/Aesculap (violet polydioxanone monofilament), the Surgicryl® PDO line from SMI and the Maxon line from Medtronic/Covidien. All must be checked against their official technical data sheet (USP gauge, thread length, colour, curvature, body, point and needle size). The brands cited belong to their respective manufacturers and are mentioned solely as comparative reference.
5. Selection tips and variants of interest
When choosing a PDO suture, always check the USP gauge according to the tissue plane: fine gauges (4/0 to 6/0) for skin and subcutaneous tissue, 3/0 and 2/0 for general soft tissue, and USP 0 and above for fascia and planes under tension, as in this reference. Needle geometry is also decisive: the reverse cutting triangular point (DS) is indicated for fibrous, low-elasticity tissues (skin, aponeuroses), while the conical point (HR) is reserved for delicate, well-perfused tissues (vessels, parenchyma).
Within the Cahnos catalogue, the PDO/PDS family of ⅜ circle with reverse cutting triangular point includes variants of interest: AM412DS3010 (standard quality, same DS30 configuration, USP 0, violet, 75 cm) as an economical alternative; AMP412DS3010.2 (double thread 2 × 75 cm, same needle) for prolonged continuous sutures; AMP412DS2620.2 (DS26 needle of 26 mm, USP 2/0, 2 × 75 cm) for a slightly smaller gauge while maintaining the double thread; AMP412DS3630 (DS36 needle of 36 mm, USP 3/0, 75 cm) for longer-reach access; and AMP418HS2620 (½ circle HS26 mm needle, USP 2/0, 70 cm) if the protocol prefers half-circle curvature. If loose thread is required for ligatures, reference AM41-2.7020 (USP 2/0, without needle, 2 × 70 cm) covers that format. Always check the USP gauge, needle size and geometry against your surgical protocol before substituting one reference for another.
As this is sterile single-use material, check the integrity of the packaging before each procedure, respect the expiry date and store the suture in a cool, dry place, protected from sunlight. For special B2B conditions, volume orders or other gauges, lengths and colours made to order, contact the technical-commercial team at Cahnos.





Reviews