We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice
Sale!

Absorbable Monofilament Polydioxanone PDO/PDS Suture – 3/8 Circle Triangular Reverse Cutting Needle DS19 (19 mm) – USP 5/0 – Violet Thread 45 cm – Box of 12 units · Ref. 411DS1950

Original price was: 44,90 €.Current price is: 36,95 €.

Polydioxanone (PDO/PDS) absorbable monofilament suture with a ⅜ circle needle, triangular reverse cutting body and point of 19 mm (DS19), USP gauge 5/0 (metric 1) and 45 cm violet grooved thread. Predictable absorption by hydrolysis in 180–210 days, with tensile strength retention of 75% at 2 weeks, 60–70% at 4 weeks and 45% at 8 weeks, providing prolonged support in slow-healing tissues. Sterilised by ethylene oxide, single-use and with minimal tissue reaction; indicated for tissue approximation, ligatures, general surgery, paediatric cardiovascular tissues and ophthalmology. Factory reference 411DS1950 · SKU AM411DS1950 · presentation in a box of 12 units.

Se fabrica bajo pedido: el fabricante exige un mínimo de 30 unidades por referencia.

International shipping. Import duties and taxes are payable by the recipient.

Reference
AM411DS1950

Description

1. Product Presentation

The absorbable monofilament Polydioxanone (PDO/PDS) suture, reference 411DS1950, is the technical reference choice when tissue requires prolonged support during healing with fully predictable reabsorption. This presentation combines a 45 cm violet grooved thread in USP 5/0 gauge with a ⅜ circle needle, reverse cutting triangular body and point of 19 mm (DS19), a geometry designed to penetrate firm and fibrous tissues with minimal drag and excellent tip control.

Available in a box of 12 units, it is a reliable and cost-effective solution for general surgery departments, paediatric cardiovascular surgery operating theatres, ophthalmology units and hospital purchasing centres seeking quality homogeneity with CE marking and gauges conforming to USP/European Pharmacopoeia.

2. Technical Explanation

Polydioxanone is a synthetic absorbable polyester —a poly(p-dioxanone) polymer— that degrades by hydrolysis, a mechanism independent of the patient’s enzymatic activity that guarantees a highly reproducible absorption kinetics. Being a monofilament, the thread has no wicking effect or capillarity: it reduces bacterial adherence, facilitates sliding through tissue and minimises the inflammatory response compared with multifilaments. Its firm feel and excellent knotting capacity make it suitable for ligatures and sutures of planes subjected to sustained tension.

The ⅜ circle needle with reverse cutting triangular body and point (reverse cutting) has the cutting edge oriented towards the outer face of the curve, allowing penetration of resistant tissues —skin, dermis, mucosa and fibrous planes— with a lower risk of tearing and a stable suture channel. The USP 5/0 gauge (metric 1) provides an optimal balance between strength and delicacy for subcutaneous tissue, fine skin, paediatric surgery and slow-healing structures. The grooved violet colour improves thread visibility on the surgical field. It is supplied sterile by ethylene oxide, single-use and cannot be re-sterilised.

3. Technical Specifications

3.1. General characteristics

Property Specification
Material Polydioxanone (PDO/PDS), absorbable synthetic monofilament polymer
Thread structure Fluted monofilament (not braided)
Gauge / size USP 5/0 (metric 1) · conforming to USP / European Pharmacopoeia
Thread length 45 cm (1 strand per unit)
Thread colour High-visibility violet, grooved
Needle shape 3/8 circle (approx. 135°)
Needle body and point Triangular, reverse cutting (reverse cutting), body and point
Needle size DS19 – 19 mm
Swaged 1 needle per suture
Absorption mechanism Hydrolysis (180–210 days)
Sterilisation Ethylene oxide (EO) — sterile, single-use, non-resterilisable
Tissue reaction Minimal, with excellent tensile strength and knot tying
Indications Tissue approximation, ligatures, general surgery, paediatric cardiovascular tissues and ophthalmology
Presentation Box of 12 sterile units (individual pouches)
Factory reference / SKU 411DS1950 / AM411DS1950

3.2. Tensile strength retention profile

Time after implantation Tensile strength retention
2 weeks 75 %
4 weeks 60–70 %
8 weeks 45 %
Complete absorption 180–210 days by hydrolysis

This prolonged force retention profile is maintained during the critical healing phase of slow-healing tissues, which is why its use is recommended in closures of fascia, aponeurosis, skin and structures subjected to sustained traction.

4. Equivalences and Cross-References

Monofilament polydioxanone is the material basis of the market reference lines for long-lasting absorbable sutures (PDS-type family). For the verified configuration of this data sheet (⅜ circle reverse cutting triangular needle of 19 mm, USP 5/0 gauge, 45 cm violet thread), no reference from another manufacturer has been found in public sources that matches field by field (material, gauge, ⅜ curvature, reverse cutting point family, 19 mm size and 45 cm length), so it is not possible to declare an exact verified reference equivalence.

There is no equivalence table validated by the manufacturer for this specific configuration; consult the technical department of Cahnos before use in tendering. As homologous market families, to be verified code by code in their official technical data sheet before any substitution, the following are cited: the PDS II® and PDS Plus® lines from Ethicon (the latter with antibacterial triclosan coating, indicated only where its use is approved), the MonoPlus® line from B. Braun/Aesculap (polydioxanone monofilament), the Surgicryl PDO line from SMI and the Maxon line from Medtronic/Covidien (made of polyglyconate, a different polymer, so its absorption profile must be verified). All must be checked field by field in their official data sheet: USP gauge, thread length, colour, curvature, body, point and needle size. The cited brands belong to their respective manufacturers and are mentioned solely as comparative reference.

5. Selection tips and variants of interest

When choosing a PDO suture, always verify the USP gauge according to the tissue plane: fine gauges (4/0 to 6/0) for skin, subcutaneous tissue and delicate tissues —as is the case with this reference—, 3/0 and 2/0 for general soft tissue and USP 0 and above for fascia and planes under tension. Needle geometry is also decisive: the reverse cutting triangular point (DS series) is indicated for fibrous and resistant tissues with controlled penetration, while the conical point (DR/HR) is reserved for delicate and well-perfused tissues (vessels, parenchyma) and the trocar point (DRT) for tissues of intermediate consistency.

Within the Cahnos catalogue, the PDO/PDS family of ⅜ circle with reverse cutting triangular point includes interesting variants: AMP411DS1950 (Prime quality, same DS19 needle, USP 5/0, 45 cm) as a higher-range alternative; AMP411DS1250 (DS12 needle, USP 5/0, 45 cm) for even smaller fields; AMP411DS1940FN (DS19 fine needle, USP 4/0, 45 cm) for slightly larger gauges; AMP412DS1930 (DS19 needle, USP 3/0, 75 cm) for planes of greater consistency; and AMP418DRT1350 (DRT13 trocar needle, USP 5/0, 70 cm) for firmer tissues. Always verify the USP gauge, size and needle geometry against your surgical protocol before substituting one reference for another.

As this is sterile single-use material, check the integrity of the packaging before each procedure, respect the expiry date and keep the suture in a cool, dry place, protected from sunlight. For special B2B conditions, volume orders or other gauges, lengths and colours made to order, contact the technical-commercial team at Cahnos.

Additional information

Material

Polydioxanone (PDO/PDS), absorbable synthetic monofilament polymer

Thread structure

Grooved monofilament

USP size

5/0 (metric 1)

Thread colour

Violet grooved

Needle tip

Triangular reverse cutting (reverse cutting), body and point

Needle size

DS19 (19 mm)

Swaged

1 needle per suture

Sterilisation

Ethylene oxide (EO), single-use, not re-sterilisable

Tissue reaction

Minimal

Indications

Tissue approximation, ligatures, general surgery, paediatric cardiovascular tissues and ophthalmology

Presentation

Box of 12 sterile units

Manufacturer reference

411DS1950

Regulatory standard

USP / European Pharmacopoeia (EP)

Medida de aguja

DS 19

Usp

5/0

Color

Violet

Medida de hilo

45 cm

Tipo de aguja

Reverse cutting

Forma de aguja

3/8 circle

Calidad sutura

Normal

Absorcion

Slow absorbable (> 120 days)

Reviews

There are no reviews yet.

Be the first to review “Absorbable Monofilament Polydioxanone PDO/PDS Suture – 3/8 Circle Triangular Reverse Cutting Needle DS19 (19 mm) – USP 5/0 – Violet Thread 45 cm – Box of 12 units · Ref. 411DS1950”

Your email address will not be published. Required fields are marked *