Cahnos.com Compare invoice

Absorbable Monofilament Polydioxanone PDO/PDS Prime Suture · ⅜ Circle Triangular Reverse Cutting Needle DS30 (30 mm) · USP Size 0 · Violet · 2 Strands of 75 cm · Box of 12 units · Ref. AMP412DS3010.2

99,46 €

Absorbable monofilament polydioxanone (PDO/PDS) Prime suture with a ⅜ circular needle, triangular body and reverse cutting grooved point, 30 mm (DS30), USP size 0 (metric 3.5), presented with 2 strands of 75 cm per pack in violet. Predictable absorption by hydrolysis between 180 and 210 days, with tensile strength retention of 75% at 2 weeks, 60–70% at 4 and 45% at 8. Sterile by ethylene oxide, single-use and with minimal tissue reaction; indicated for tissue approximation, ligatures, general surgery, fascia closure, paediatric cardiovascular tissues and ophthalmology. Presentation in a box of 12 sterile units with B2B conditions for hospitals and purchasing centres. Factory ref. P412DS3010.2 · SKU AMP412DS3010.2.

International shipping. Import duties and taxes are payable by the recipient.

Reference
AMP412DS3010.2

Description

1. Product Presentation

The Prime line’s absorbable monofilament polydioxanone (PDO/PDS) suture is the reference technical choice when the tissue needs prolonged support during healing and fully predictable reabsorption. This presentation combines a 75 cm violet grooved thread in USP 0 gauge with a ⅜ circle needle, triangular body and 30 mm reverse cutting point (DS30), a geometry designed to pass through fibrous tissue with a clean and controlled passage. Each pack includes 2 threads with needle, which optimises performance per unit in the operating theatre.

Available in a box of 12 sterile units, it is a reliable and cost-effective solution for general surgery departments, paediatric cardiovascular surgery operating theatres, ophthalmology units and hospital purchasing centres seeking quality consistency with CE marking.

2. Technical Explanation

Polydioxanone is an absorbable synthetic polyester —a poly(p-dioxanone) polymer— that degrades by hydrolysis, a mechanism independent of the patient’s enzymatic activity that ensures a highly reproducible absorption kinetics between individuals. Being a monofilament, the thread has no wicking effect or capillarity, which reduces bacterial adherence, facilitates sliding through tissue and minimises the inflammatory response compared to multifilament. Its firm feel and excellent knotting capacity make it ideal for ligatures and sutures of planes subjected to sustained tension during the critical healing phase.

The ⅜ circle needle with reverse cutting triangular point presents the cutting edge on the outer face of the curve, which avoids tearing of superficial tissue and makes it especially suitable for skin, subcutaneous tissue, aponeurosis and other fibrous planes. With 30 mm length (DS30) and USP 0 gauge (metric 3.5), this configuration offers high tensile strength for planes under tension. The grooved violet colour improves thread visibility on the surgical field and knot security. It is supplied sterile by ethylene oxide, single-use and with no possibility of re-sterilisation.

3. Technical Specifications

3.1. General characteristics

Parameter Specification
Material Polydioxanone (PDO/PDS), absorbable synthetic monofilament polymer
Thread structure Grooved monofilament
Quality Prime
Gauge / size USP 0 (metric 3.5)
Thread length 75 cm per thread (2 x 75 cm per pack)
Thread colour Violet (high visibility)
Needle shape ⅜ circle
Needle body and point Triangular, reverse cutting point, grooved
Needle size DS30 – 30 mm
Swaged 2 needles per pack (double thread)
Absorption mechanism Hydrolysis (180–210 days)
Sterilisation Ethylene oxide (single-use, not re-sterilisable)
Tissue reaction Minimal, with excellent tensile strength and knot tying
Indications Tissue approximation, ligatures, general surgery, fascia, paediatric cardiovascular tissues and ophthalmology
Presentation Box of 12 sterile units (individual pack)
Factory reference / SKU P412DS3010.2 / AMP412DS3010.2

3.2. Tensile strength retention profile

Time Tensile strength retention
2 weeks 75 %
4 weeks 60–70 %
8 weeks 45 %
Complete absorption 180–210 days by hydrolysis

This prolonged force retention profile is maintained during the critical healing phase of slow-healing tissues, so its use is recommended in closures of fascia, aponeurosis and structures subjected to sustained traction.

4. Equivalences and Cross-References

Monofilament polydioxanone is the material basis of the market reference lines for long-lasting absorbable sutures (PDS-type family). On the verified configuration of this data sheet (⅜ circular reverse cutting triangular needle of 30 mm, USP 0 gauge, violet thread of 2 x 75 cm), the following commercial reference from another manufacturer has been compared in primary sources:

Manufacturer / Brand Family / Model Reference code / SKU Equivalence level Technical differences / Remarks
Ethicon (Johnson & Johnson MedTech) PDS II® (polydioxanone) violet monofilament, USP 0 gauge Z970H Comparable by category (not interchangeable 1:1) Same PDO monofilament material and same USP 0 gauge, confirmed on GUDID/FDA regulatory basis and authorised distributors. They differ: CP-2 needle of ½ circle with 26 mm reverse cutting point versus the ⅜ circle DS30 needle of 30 mm of this reference, and thread length of 70 cm versus 2 x 75 cm (double thread).

There is no equivalence table validated by the manufacturer that officially cross-references this reference with the commercial series of other brands; consult the technical department before use in tenders. As homologous market families to verify code by code before a substitution: the PDS II® and PDS Plus® lines from Ethicon (the latter with antibacterial triclosan coating, indicated only where its use is approved), the MonoPlus® line from B. Braun/Aesculap (violet polydioxanone monofilament), the Surgicryl® PDO line from SMI and the Maxon line from Medtronic/Covidien. All must be checked in their official technical data sheet (USP gauge, thread length, colour, curvature, body, point and needle size). The cited brands belong to their respective manufacturers and are mentioned only as comparative reference.

5. Selection tips and variants of interest

When choosing a PDO suture, always verify the USP gauge according to the tissue plane: fine gauges (4/0 to 6/0) for skin and subcutaneous tissue, 3/0 and 2/0 for general soft tissue, and USP 0 and above for fascia and planes under tension, as in this reference. The needle geometry is also decisive: the reverse cutting triangular point (DS) is indicated for fibrous and poorly elastic tissues (skin, aponeurosis), while the conical point (HR) is reserved for delicate and well-perfused tissues (vessels, parenchyma). The double thread format (2 x 75 cm) is especially efficient in prolonged continuous sutures and in procedures where both threads per pack are used.

Within the Cahnos catalogue, the PDO/PDS family of ⅜ circle with reverse cutting triangular point includes interesting variants: AMP412DS2620.2 (DS26 needle of 26 mm, USP 2/0, 2 x 75 cm) for a slightly lower gauge while maintaining the double thread; AMP412DS3630 (DS36 needle of 36 mm, USP 3/0, 75 cm) for accesses of greater reach; and AMP418HS2620 (½ circle HS26 mm needle, USP 2/0, 70 cm) if the protocol prefers half-circumference curvature. If loose thread is required for ligatures, the reference AM41-2.7020 (USP 2/0, without needle, 2 x 70 cm) covers that format. Always verify the USP gauge, size and geometry of the needle against your surgical protocol before substituting one reference for another.

As it is sterile single-use material, check the integrity of the packaging before each procedure, respect the expiry date and store the suture in a cool, dry place, protected from sunlight. For special B2B conditions, volume orders or other gauges, lengths and colours on request, contact the technical-commercial team of Cahnos.

Additional information

Material

Polydioxanone (PDO/PDS), synthetic grooved monofilament

USP size

0 (metric 3.5)

Needle size

DS30 – 30 mm

Needle tip

Triangular reverse cutting (reverse cutting), grooved

Swaged

2 threads with needle per pack (double thread)

Sterilisation

Ethylene oxide, single-use, non-resterilizable

Presentation

Box of 12 sterile units

Manufacturer reference

P412DS3010.2

Indications

Tissue approximation, ligatures, general surgery, fascia, paediatric cardiovascular tissues and ophthalmology

Medida de aguja

DS 30

Usp

0

Color

Violet

Medida de hilo

2 × 75 cm

Tipo de aguja

Reverse cutting

Forma de aguja

3/8 circle

Calidad sutura

Prime

Absorcion

Slow absorbable (> 120 days)

Reviews

There are no reviews yet.

Be the first to review “Absorbable Monofilament Polydioxanone PDO/PDS Prime Suture · ⅜ Circle Triangular Reverse Cutting Needle DS30 (30 mm) · USP Size 0 · Violet · 2 Strands of 75 cm · Box of 12 units · Ref. AMP412DS3010.2”