Description
1. Product Presentation
The Prime line’s absorbable monofilament polydioxanone (PDO/PDS) suture is the reference technical choice when the tissue needs prolonged support during healing and fully predictable reabsorption. This presentation combines a 75 cm violet grooved thread in USP 0 gauge with a ⅜ circle needle, triangular body and 30 mm reverse cutting point (DS30), a geometry designed to pass through fibrous tissue with a clean and controlled passage. Each pack includes 2 threads with needle, which optimises performance per unit in the operating theatre.
Available in a box of 12 sterile units, it is a reliable and cost-effective solution for general surgery departments, paediatric cardiovascular surgery operating theatres, ophthalmology units and hospital purchasing centres seeking quality consistency with CE marking.
2. Technical Explanation
Polydioxanone is an absorbable synthetic polyester —a poly(p-dioxanone) polymer— that degrades by hydrolysis, a mechanism independent of the patient’s enzymatic activity that ensures a highly reproducible absorption kinetics between individuals. Being a monofilament, the thread has no wicking effect or capillarity, which reduces bacterial adherence, facilitates sliding through tissue and minimises the inflammatory response compared to multifilament. Its firm feel and excellent knotting capacity make it ideal for ligatures and sutures of planes subjected to sustained tension during the critical healing phase.
The ⅜ circle needle with reverse cutting triangular point presents the cutting edge on the outer face of the curve, which avoids tearing of superficial tissue and makes it especially suitable for skin, subcutaneous tissue, aponeurosis and other fibrous planes. With 30 mm length (DS30) and USP 0 gauge (metric 3.5), this configuration offers high tensile strength for planes under tension. The grooved violet colour improves thread visibility on the surgical field and knot security. It is supplied sterile by ethylene oxide, single-use and with no possibility of re-sterilisation.
3. Technical Specifications
3.1. General characteristics
| Parameter | Specification |
|---|---|
| Material | Polydioxanone (PDO/PDS), absorbable synthetic monofilament polymer |
| Thread structure | Grooved monofilament |
| Quality | Prime |
| Gauge / size | USP 0 (metric 3.5) |
| Thread length | 75 cm per thread (2 x 75 cm per pack) |
| Thread colour | Violet (high visibility) |
| Needle shape | ⅜ circle |
| Needle body and point | Triangular, reverse cutting point, grooved |
| Needle size | DS30 – 30 mm |
| Swaged | 2 needles per pack (double thread) |
| Absorption mechanism | Hydrolysis (180–210 days) |
| Sterilisation | Ethylene oxide (single-use, not re-sterilisable) |
| Tissue reaction | Minimal, with excellent tensile strength and knot tying |
| Indications | Tissue approximation, ligatures, general surgery, fascia, paediatric cardiovascular tissues and ophthalmology |
| Presentation | Box of 12 sterile units (individual pack) |
| Factory reference / SKU | P412DS3010.2 / AMP412DS3010.2 |
3.2. Tensile strength retention profile
| Time | Tensile strength retention |
|---|---|
| 2 weeks | 75 % |
| 4 weeks | 60–70 % |
| 8 weeks | 45 % |
| Complete absorption | 180–210 days by hydrolysis |
This prolonged force retention profile is maintained during the critical healing phase of slow-healing tissues, so its use is recommended in closures of fascia, aponeurosis and structures subjected to sustained traction.
4. Equivalences and Cross-References
Monofilament polydioxanone is the material basis of the market reference lines for long-lasting absorbable sutures (PDS-type family). On the verified configuration of this data sheet (⅜ circular reverse cutting triangular needle of 30 mm, USP 0 gauge, violet thread of 2 x 75 cm), the following commercial reference from another manufacturer has been compared in primary sources:
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
|---|---|---|---|---|
| Ethicon (Johnson & Johnson MedTech) | PDS II® (polydioxanone) violet monofilament, USP 0 gauge | Z970H | Comparable by category (not interchangeable 1:1) | Same PDO monofilament material and same USP 0 gauge, confirmed on GUDID/FDA regulatory basis and authorised distributors. They differ: CP-2 needle of ½ circle with 26 mm reverse cutting point versus the ⅜ circle DS30 needle of 30 mm of this reference, and thread length of 70 cm versus 2 x 75 cm (double thread). |
There is no equivalence table validated by the manufacturer that officially cross-references this reference with the commercial series of other brands; consult the technical department before use in tenders. As homologous market families to verify code by code before a substitution: the PDS II® and PDS Plus® lines from Ethicon (the latter with antibacterial triclosan coating, indicated only where its use is approved), the MonoPlus® line from B. Braun/Aesculap (violet polydioxanone monofilament), the Surgicryl® PDO line from SMI and the Maxon line from Medtronic/Covidien. All must be checked in their official technical data sheet (USP gauge, thread length, colour, curvature, body, point and needle size). The cited brands belong to their respective manufacturers and are mentioned only as comparative reference.
5. Selection tips and variants of interest
When choosing a PDO suture, always verify the USP gauge according to the tissue plane: fine gauges (4/0 to 6/0) for skin and subcutaneous tissue, 3/0 and 2/0 for general soft tissue, and USP 0 and above for fascia and planes under tension, as in this reference. The needle geometry is also decisive: the reverse cutting triangular point (DS) is indicated for fibrous and poorly elastic tissues (skin, aponeurosis), while the conical point (HR) is reserved for delicate and well-perfused tissues (vessels, parenchyma). The double thread format (2 x 75 cm) is especially efficient in prolonged continuous sutures and in procedures where both threads per pack are used.
Within the Cahnos catalogue, the PDO/PDS family of ⅜ circle with reverse cutting triangular point includes interesting variants: AMP412DS2620.2 (DS26 needle of 26 mm, USP 2/0, 2 x 75 cm) for a slightly lower gauge while maintaining the double thread; AMP412DS3630 (DS36 needle of 36 mm, USP 3/0, 75 cm) for accesses of greater reach; and AMP418HS2620 (½ circle HS26 mm needle, USP 2/0, 70 cm) if the protocol prefers half-circumference curvature. If loose thread is required for ligatures, the reference AM41-2.7020 (USP 2/0, without needle, 2 x 70 cm) covers that format. Always verify the USP gauge, size and geometry of the needle against your surgical protocol before substituting one reference for another.
As it is sterile single-use material, check the integrity of the packaging before each procedure, respect the expiry date and store the suture in a cool, dry place, protected from sunlight. For special B2B conditions, volume orders or other gauges, lengths and colours on request, contact the technical-commercial team of Cahnos.





Reviews