Description
1. Introduction
The absorbable monofilament polydioxanone (PDO/PDS) suture we present is the reference option when prolonged tissue support is required with fully predictable resorption and minimal tissue reaction. This presentation combines a violet grooved 70 cm thread in USP 4/0 gauge with a ½ circle needle, cylindrical body and trocar point (Tapercut) of 17 mm (HRT17), designed to penetrate firm or moderately resistant tissues without splitting delicate structures. It is supplied in a box of 12 sterile units, ready for use in the operating theatre and for hospital tenders.
2. Technical Explanation
Polydioxanone is a synthetic absorbable polyester (poly(p-dioxanone) polymer) that degrades by hydrolysis, a mechanism independent of the patient’s enzymatic activity that guarantees highly reproducible absorption kinetics between individuals, with complete resorption between 180 and 210 days.
As it is a monofilament, the thread does not present a wicking effect or interstitial spaces where microorganisms can colonise: it passes through tissue with low friction, reducing trauma and the saw effect, and offers excellent knotting ability. The ½ circle needle with cylindrical body and trocar point (Tapercut) combines the penetration of a cutting point with the atraumatic passage of a cylindrical needle: it is ideal for tissues of firm or moderately resistant consistency (fascia, aponeurosis, thick-walled vessels) and for paediatric cardiovascular surgery, where precision without tearing is required. The USP 4/0 gauge (metric 1.5) is suitable for fine and delicate tissues: skin, subcutaneous tissue, paediatric, plastic and ophthalmic surgery.
3. Technical Specifications
3.1. General characteristics
| Parameter | Specification |
|---|---|
| Material | Polydioxanone (PDO/PDS), synthetic absorbable monofilament of poly(p-dioxanone) |
| Gauge | USP 4/0 (metric 1.5) |
| Thread length | 70 cm |
| Thread colour | Violet grooved |
| Needle shape | ½ circle (half circumference) |
| Needle body | Cylindrical |
| Needle tip | Trocar / Tapercut (cylindrical body with cutting point) |
| Needle size | 17 mm (HRT17), one needle |
| Absorption mechanism | Hydrolysis, 180–210 days |
| Sterilisation | Ethylene oxide (single-use, not re-sterilisable) |
| Tissue reaction | Minimal, with excellent tensile strength and knot tying |
| Indications | Tissue approximation, ligatures, general surgery, paediatric cardiovascular tissues, ophthalmology and microsurgery |
| Presentation | Box of 12 units |
| Reference | 418HRT1740 · SKU AM418HRT1740 |
3.2. Tensile strength retention profile
| Period | % of retained tensile strength |
|---|---|
| 2 weeks | ≈ 75 % |
| 4 weeks | 60–70 % |
| 8 weeks | ≈ 45 % |
| Complete absorption | 180–210 days by hydrolysis |
This retention profile is maintained during the critical healing phase of slow-healing tissues, which recommends its use in closures of fascia, aponeurosis and structures subjected to sustained tension.
4. Equivalences and Cross-References
Polydioxanone monofilament is the material basis of the market reference lines for long-lasting absorbable sutures (PDS type). Based on the verified configuration of this technical data sheet (½ circle needle with 17 mm trocar point, USP 4/0 gauge, 70 cm violet thread), the following commercial references from other manufacturers have been cross-checked in primary sources (official Ethicon EPC catalogue and authorised distributors):
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
|---|---|---|---|---|
| Ethicon (Johnson & Johnson MedTech) | PDS II (polydioxanone), Tapercut | Z137H | Comparable by category (not interchangeable 1:1) | Same PDO monofilament material, USP 4/0 gauge, violet, and V-5 ½ circle Tapercut needle of 17 mm; differs in the configuration (double needle V-5/V-5 versus one needle for this reference), thread length (90 cm versus 70 cm) and presentation (36 units versus 12 units). |
| Ethicon (Johnson & Johnson MedTech) | PDS II (polydioxanone), taper point | Z315H | Comparable by category (not interchangeable 1:1) | Same PDO monofilament material, USP 4/0 gauge, 70 cm violet thread and ½ circle curvature; differs in the needle point (taper point SH of 26 mm versus trocar/Tapercut point of 17 mm for this reference). |
There is no equivalence table validated by the manufacturer; consult the technical department before use in tenders. As homologous category families (same indication and polymer, without code verified in primary source for this exact configuration), the Ethicon PDS Plus line (same PDO base with antibacterial triclosan coating), the B. Braun MonoPlus line and the SMI Surgicryl PDO line are cited; in all cases, the USP gauge, thread length, configuration (1 or 2 needles), point geometry and needle size must be verified in the official technical data sheet before substitution.
5. Selection tips and variants of interest
The trocar point (Tapercut) is indicated when the tissue offers resistance to advancement (fascia, aponeurosis, scar tissue) but tearing is to be minimised; in very friable tissues, consider the taper point variant of the same family. The USP 4/0 gauge is suitable for fine and delicate tissues: skin, subcutaneous tissue, paediatric, plastic and ophthalmic surgery.
Within the Cahnos catalogue you will find variants of the same PDO/PDS ½ circle trocar point HRT17 family: the Prime quality version with identical configuration (AMP418HRT1740), other gauges with the same needle (USP 3/0 ref. AM418HRT1730, USP 2/0 ref. AM418HRT1720, USP 5/0 ref. AM418HRT1750), the double needle taper point version (AM418HR1740-2) and alternatives in PGA multifilament with the same HRT17 needle (AM118HRT1740). Select the needle size according to the thickness and density of the tissue (13–17 mm for delicate tissues; 22–26 mm for fascia and general surgery) and always verify the USP gauge indicated in the surgical technique of the procedure. As it is sterile single-use material, check the integrity of the packaging before each intervention. For special B2B conditions, volume orders or gauges made to order, contact the technical-commercial team of Cahnos.





Reviews