We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice

Prime Absorbable Monofilament Polydioxanone (PDO/PDS) Suture | USP 4/0 | Needle ½ Circle Cylindrical Body Taperpoint Conical Point HR 26 mm | Violet 70 cm | Box of 12 units | Ref. AMP418HR2640

45,64 €

Absorbable monofilament polydioxanone (PDO/PDS) suture in Prime quality, with a ½ circle needle with cylindrical body and Taperpoint conical point of 26 mm (HR 26), USP 4/0 gauge and violet thread of 70 cm. Predictable absorption by hydrolysis in 180–210 days, with tensile strength retention of 75% at 2 weeks, 60–70% at 4, and 45% at 8. Sterilised by ethylene oxide, single-use and minimal tissue reaction; indicated for tissue approximation, ligatures, general surgery, paediatric cardiovascular tissues and ophthalmology. Presentation in box of 12 units, factory reference P418HR2640 (SKU AMP418HR2640).

International shipping. Import duties and taxes are payable by the recipient.

Reference
AMP418HR2640

Description

1. Product Presentation

The absorbable monofilament polydioxanone (PDO/PDS) suture from the Prime range, reference AMP418HR2640 (factory P418HR2640), is the professional solution for the surgeon who needs a thread with prolonged absorption, excellent handling and maximum knot security in the approximation of soft tissues and ligatures. It incorporates a ½ circle needle with cylindrical body and 26 mm Taperpoint conical point (HR 26), 70 cm violet thread and USP 4/0 gauge.

Medical device synthetic absorbable, sterile and single-use, with a very competitive price-quality ratio for B2B procurement for operating theatres, general surgery departments, paediatric cardiovascular surgery units, ophthalmology departments and purchasing centres. Commercial presentation in a box of 12 units.

2. Technical explanation

Polydioxanone is a synthetic absorbable polymer —poly(p-dioxanone)— presented in a monofilament structure, which gives it a smooth surface that reduces friction when passing through tissue, minimises the sawing effect and hinders bacterial adhesion. Its degradation occurs by hydrolysis, that is, by cleavage of the polymer chains in contact with organic fluids, over a predictable period of 180 to 210 days.

This slow absorption profile maintains the necessary tensile strength during the critical phases of healing, being especially useful in tissues that require prolonged support, superior to that of braided PGA or PGLA sutures. The ½ circle needle with cylindrical body and Taperpoint conical point separates the fibres without a cutting effect, making it atraumatic in delicate structures such as vessels, parenchyma, paediatric cardiovascular tissue and ocular tissue. The product is sterilised by ethylene oxide, is single-use and cannot be re-sterilised.

3. Technical Specifications

3.1. General characteristics of reference AMP418HR2640

Parameter Specification
Reference (SKU) AMP418HR2640 (factory ref. P418HR2640)
Material Polydioxanone (PDO/PDS), poly(p-dioxanone) synthetic monofilament
Thread structure Monofilament (not braided, not grooved)
Quality Prime (premium range)
Gauge USP 4/0 (metric 1.5)
Thread colour Violet for high surgical visibility
Thread length 70 cm
Swaged 1 needle (single mounted needle)
Needle shape ½ circle (half circumference)
Needle body Cylindrical
Tip type Taperpoint conical (atraumatic)
Needle size HR 26 – 26 mm
Absorption mechanism Hydrolysis, 180–210 days
Sterilisation Ethylene oxide (EO), single-use, not re-sterilisable
Tissue reaction Minimal
Indications Tissue approximation, ligatures, general surgery, paediatric cardiovascular tissues and ophthalmology
Presentation Box of 12 sterile units

3.2. Tensile strength retention profile

Period after implantation Tensile strength retention
2 weeks 75 %
4 weeks 60–70 %
8 weeks 45 %
Complete absorption Between 180 and 210 days by hydrolysis, with minimal tissue reaction

Excellent tensile strength, optimal knot tying and a fully predictable absorption rate.

4. Equivalences and Cross-References

Monofilament polydioxanone is the most well-established synthetic absorbable suture material with prolonged absorption on the market (PDS-type lines). There is no official equivalence table validated by the manufacturer declaring a 1:1 correspondence with other brands; the verified references indicated below are comparable at category level, not interchangeable point by point, and must be checked field by field (material, gauge, length, colour, curvature, needle size and point) before any substitution.

Manufacturer / Brand Family / Model Reference code / SKU Equivalence level Technical differences / Remarks
Ethicon (Johnson & Johnson MedTech) PDS II® – monofilament polydioxanone, USP 4/0, violet, 70 cm (27″), SH needle of 26 mm, ½ circle, conical point (taper point) Z315H Comparable by category (not interchangeable 1:1) Confirmed in the official Ethicon catalogue and authorised distributors: material, USP 4/0 gauge, 70 cm thread length, violet colour and ½ circle 26 mm needle with conical point all match. The presentation differs (box of 36 units vs. 12 units) and the brand.
Ethicon (Johnson & Johnson MedTech) PDS II® – monofilament polydioxanone, 70 cm, SH needle, violet W9205H Comparable by category (not interchangeable 1:1) Code verified in catalogues of specialised distributors: same base PDS II configuration of 70 cm with 26 mm SH needle; verify the exact gauge of the unit before substitution.
Ethicon (Johnson & Johnson MedTech) PDS Plus® – polydioxanone with antibacterial triclosan coating, USP 4/0, violet, 70 cm, 26 mm SH needle, ½ circle, conical point PDP315H Comparable by category (not interchangeable 1:1) Confirmed in the official Ethicon catalogue: base material, gauge, colour, length and needle size (26 mm) match; it incorporates triclosan coating (Irgacare MP) and presentation of 36 units.

There is no equivalence table validated by the manufacturer for an exact 1:1 cross-reference with the HR 26 Taperpoint needle configuration in gauge 4/0; consult the technical department before use in tenders. As homologous market families, to be verified reference by reference in their official datasheet before substitution, the MonoPlus® line from B. Braun (violet monofilament polydioxanone, HR 26 needles), the Maxon line from Medtronic/Covidien and the Surgicryl PDO line from SMI are cited, checking in each case USP 4/0 gauge, ½ circle curvature, 26 mm needle size, conical point, 70 cm length and violet colour.

5. Selection tips and variants of interest

The USP 4/0 gauge (metric 1.5) is ideal for fine tissues and low-moderate tension: approximation of subcutaneous tissue, fine fascia, mucosa, microsurgery and ligatures of small-calibre vessels, as well as paediatric cardiovascular surgery and ophthalmology. The ½ circle needle with 26 mm Taperpoint conical point guarantees atraumatic entry into delicate tissues; if greater penetration is required in firm or slightly fibrous tissues, consider the trocar point (Tapercut) versions of the same family (HRT series).

Reference Description
AMP418HR2630-2 PDO Prime, double needle HR 26 mm Taperpoint conical point, USP 3/0, violet, 70 cm (thicker gauge, double needle)
AMP418HR2240-2 PDO Prime, double needle HR 22 mm conical point, USP 4/0, violet, 70 cm (shorter needle)
AMP418HRT2640 PDO Prime, HRT 26 mm trocar point needle, USP 4/0, violet, 70 cm (greater penetration)
AMP418HRP2640 PDO Prime, HRP 26 mm needle, USP 4/0, violet, 70 cm (atraumatic point from the HRP series)
AMP318HR2640 PGCL (poliglecaprone 25) Prime, HR 26 mm conical point needle, USP 4/0, violet, 70 cm (medium absorption 90–120 days)
AMP118HR2640 PGA Prime multifilament, HR 26 mm conical point needle, USP 4/0, violet, 70 cm (short absorption 60–90 days)

Keep the original packaging in a dry, cool place, respect the expiry date and handle the thread with gloves to avoid altering its mechanical properties. For special B2B conditions by volume, hospital traceability or equivalences from other commercial brands, contact our technical-commercial team at Cahnos.

Additional information

Material

Polydioxanone (PDO/PDS), poly(p-dioxanone)

Gauge

USP 4/0 (metric 1.5)

Needle body

Cylindrical

Needle tip

Taperpoint conical

Needle size

26 mm (HR 26)

Swaged

1 needle

Absorption mechanism

Hydrolysis, 180-210 days

Strength retention

75% at 2 weeks; 60-70% at 4 weeks; 45% at 8 weeks

Sterilisation

Ethylene oxide (EO)

Use

Single-use, not re-sterilisable

Indications

Tissue approximation, ligatures, general surgery, paediatric cardiovascular surgery and ophthalmology

Presentation

Box of 12 units

Manufacturer reference

P418HR2640

Medida de aguja

HR 26

Usp

4/0

Color

Violet

Medida de hilo

70 cm

Tipo de aguja

Cylindrical

Forma de aguja

1/2 circle

Calidad sutura

Prime

Estructura hilo

Monofilament

Reviews

There are no reviews yet.

Be the first to review “Prime Absorbable Monofilament Polydioxanone (PDO/PDS) Suture | USP 4/0 | Needle ½ Circle Cylindrical Body Taperpoint Conical Point HR 26 mm | Violet 70 cm | Box of 12 units | Ref. AMP418HR2640”

Your email address will not be published. Required fields are marked *