We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice

Prime Absorbable Monofilament Polydioxanone (PDO/PDS) Suture · Double Needle ½ Circle Cylindrical Body Taperpoint Conical Point HR17 of 17 mm · USP 4/0 (Metric 1.5) · Violet Thread 2×70 cm · Box of 12 units (Ref. P418HR1740-2 · SKU AMP418HR1740-2)

55,30 €

Absorbable monofilament polydioxanone (PDO/PDS) suture in Prime quality with a double ½-circle needle, cylindrical body and Taperpoint conical point of 17 mm (HR17), USP size 4/0 (metric 1.5) and grooved violet thread of 2×70 cm. Predictable absorption by hydrolysis between 180 and 210 days, with tensile strength retention of 75% at 2 weeks, 60-70% at 4 weeks and 45% at 8 weeks. Sterile by ethylene oxide, single-use, with minimal tissue reaction and excellent knot security. Indicated for tissue approximation, ligatures, general surgery, paediatric cardiovascular tissues and ophthalmology. Factory ref. P418HR1740-2, presentation in a box of 12 units (SKU AMP418HR1740-2).

International shipping. Import duties and taxes are payable by the recipient.

Reference
AMP418HR1740-2

Description

1. Product Presentation

The absorbable monofilament polydioxanone (PDO/PDS) suture from the Prime range, reference P418HR1740-2, is the professional choice for surgery departments, ophthalmology, paediatric cardiovascular surgery units and purchasing centres seeking an absorbable thread with prolonged support, predictable behaviour and high knot security. It features a double needle of ½ circle with cylindrical body and conical point (taperpoint) of 17 mm, USP gauge 4/0 and violet thread of 2×70 cm.

Supplied sterile, in individual sachets, with a professional presentation of a box of 12 units and batch traceability, in B2B conditions suitable for operating theatres, ophthalmology clinics and tenders. Cahnos markets this reference keeping the factory code P418HR1740-2 unchanged (SKU AMP418HR1740-2).

2. Technical Explanation

Polydioxanone is a synthetic absorbable polyester, a polymer of poly(p-dioxanone), presented in a monofilament structure. This configuration gives the thread a smooth surface that reduces friction when passing through tissue, minimises the sawing effect, hinders bacterial adherence and provides excellent handling and knot security. Its degradation occurs by hydrolysis, i.e., by scission of the polymer chains in contact with organic fluids, over a predictable period of 180 to 210 days and independent of the patient’s enzymatic activity, with minimal tissue reaction.

The double-armed (2xHR17) configuration allows continuous suturing with anchoring at both ends, very common in laparoscopy and in continuous layer suturing techniques. The ½ circle needle with cylindrical body and 17 mm taperpoint conical point (HR17) passes through tissue atraumatically, separating the fibres without cutting effect: a configuration common in ophthalmic surgery, approximation of delicate tissues and fine vascular ligatures. The violet colour ensures optimal visibility on the surgical field. The product is sterilised by ethylene oxide (EO), is single-use and cannot be re-sterilised.

3. Technical Specifications

3.1. Technical data sheet for reference P418HR1740-2

Parameter Specification
Factory reference P418HR1740-2
Reference Cahnos (SKU) AMP418HR1740-2
Brand / Quality Prime (premium range)
Material Polydioxanone (PDO/PDS), polymer of poly(p-dioxanone)
Thread structure Synthetic monofilament, grooved
USP / metric gauge 4/0 (metric 1.5)
Thread colour Violet
Thread length 2 x 70 cm (double needle)
Needle shape ½ circle
Needle body Cylindrical
Needle tip Conical (taperpoint), atraumatic
Needle size 17 mm (2 x HR17)
Configuration Double needle (2 x HR17)
Absorption mechanism Hydrolysis (180-210 days)
Sterilisation Ethylene oxide (EO), sterile, single-use
Tissue reaction Minimal
Indications Tissue approximation, ligatures, general surgery, paediatric cardiovascular tissues and ophthalmology
Presentation Box of 12 units

3.2. Tensile strength retention and absorption profile

Period after implantation Retained tensile strength
2 weeks 75 % of initial tensile strength
4 weeks 60-70 % of the initial tensile strength
8 weeks 45 % of the initial tensile strength
Total absorption 180-210 days, by hydrolysis

Predictable and controlled absorption profile, with minimal tissue reaction, excellent tensile strength and optimal knot tying. Price per box of 12 units.

4. Equivalences and Cross-References

Monofilament polydioxanone is the most well-established synthetic absorbable suture material with prolonged absorption on the market (family type ‘PDS’). The USP 4/0 configuration, 70 cm violet thread and double ½ circle needle with 17 mm conical point corresponds to international reference lines; however, the Prime finish of the needle and the presentation in a box of 12 units are specific to this reference, so the indicated cross-references are comparable at category level and not interchangeable point by point:

Manufacturer / Brand Family / Model Reference code / SKU Equivalence level Technical differences / Remarks
B. Braun MonoPlus® — monofilament polydioxanone, violet, USP 4/0 (1.5), 70 cm, double ½ circle needle of 17 mm, conical point (taper point) C0024614 Comparable by category (not interchangeable 1:1) Verified in the official B. Braun catalogue: polymer, gauge, colour, length, curvature, point type (conical taper point), needle size (17 mm) and double-arming (2xHR17) match; the needle finish and commercial presentation differ.

For single-needle configurations with the same technical profile, the homologous reference lines are Ethicon PDS® II (e.g. Z304H, USP 4/0, violet, 70 cm, RB-1 needle of 17 mm) and B. Braun MonoPlus® (e.g. C0024014, single HR17 needle), which maintain the same polymer, gauge, colour, curvature and needle size but with single arming compared to the double arming of this reference.

There is no equivalence table validated by the manufacturer for this reference against third-party brands; consult the technical department before use in tenders. Before substituting, check on the candidate’s data sheet: USP gauge, thread length, needle configuration (1 needle / double needle), point type (conical, trocar/tapercut or reverse cutting), curvature (½ or ⅜), needle size, coating and regulatory classification (CE/MDR) of the actual product.

5. Selection tips and variants of interest

The USP 4/0 gauge (metric 1.5) is suitable for fine tissues and low-to-medium tension: skin, subcutaneous tissue, mucosa, microsurgery, fine vascular ligatures and precision approximations, with special application in ophthalmology and paediatric cardiovascular surgery. The double-armed 2×70 cm facilitates continuous suturing with anchoring at both ends, very useful in laparoscopy and deep planes. The 17 mm conical point needle is the most atraumatic option for these tissues.

Reference (SKU) Description
AMP418HR1740-2 PDO Prime, double needle 2xHR17 taper point, USP 4/0, violet, 2×70 cm (this product)
AM418HR1740-2 PDO Normal quality, double needle 2xHR17 conical point, USP 4/0, violet, 2×70 cm (economical alternative, same configuration)
AMP418HR1740 PDO Prime, HR17 needle taper point, USP 4/0, violet, 70 cm (single armed)
AMP418HRT1740-2 PDO Prime, double needle 2xHRT17 trocar point (tapercut), USP 4/0, violet, 70 cm (cutting point for denser tissues)
AMP418HRP1740-2 PDO Prime, double needle 2xHRP17 Ultra Plus taper point, USP 4/0, violet, 70 cm (precision point finish)
AMP318HR1740-2VB PGCL poliglecaprone 25 Prime, double needle 2xHR17 conical point VisiBlack, USP 4/0, violet, 70 cm (shorter absorption profile)

If a shorter absorption profile is required, consider the multifilament families in the catalogue (PGLA polyglactin 910 or PGA) with the same HR17 needle. As this is sterile single-use material, check the integrity of the packaging before each procedure, respect the expiry date and keep the reference P418HR1740-2 and the batch number for traceability in the operating theatre. Store in a cool, dry place, below 30 °C and protected from sunlight. For special B2B conditions by volume, hospital supply agreements or validation of equivalents from other commercial houses, contact the technical-commercial team at Cahnos.

Additional information

Material

Polydioxanone (PDO/PDS), polymer of poly(p-dioxanone)

Structure

Grooved synthetic monofilament

USP size

4/0 (metric 1.5)

Needle body

Cylindrical

Needle tip

Conical Taperpoint, atraumatic

Needle size

17 mm (2 x HR17)

Configuration

Double needle (2xHR17)

Absorption mechanism

Hydrolysis (180-210 days)

Sterilisation

Ethylene oxide (EO), single-use

Presentation

Box of 12 units

Manufacturer reference

P418HR1740-2

Indications

Tissue approximation, ligatures, general surgery, paediatric cardiovascular surgery and ophthalmology

Medida de aguja

2xHR 17 prime, HR 17

Usp

4/0

Color

Violet

Medida de hilo

2 × 70 cm, 70 cm

Tipo de aguja

Cylindrical

Forma de aguja

1/2 circle

Calidad sutura

Prime

Reviews

There are no reviews yet.

Be the first to review “Prime Absorbable Monofilament Polydioxanone (PDO/PDS) Suture · Double Needle ½ Circle Cylindrical Body Taperpoint Conical Point HR17 of 17 mm · USP 4/0 (Metric 1.5) · Violet Thread 2×70 cm · Box of 12 units (Ref. P418HR1740-2 · SKU AMP418HR1740-2)”

Your email address will not be published. Required fields are marked *