1. Introduction
The Prime-quality polydioxanone PDO/PDS absorbable monofilament suture is the reference solution for closing and approximating soft tissues that require prolonged wound support. Its slow, predictable absorption profile, together with excellent tensile strength, makes it a common choice in the operating theatre for both scheduled surgery and emergency procedures.
This presentation incorporates a ½-circle needle with cylindrical body and conical point (Taperpoint) of 30 mm, USP 3/0 gauge and 75 cm violet thread, in a box of 12 sterile units.
2. Technical Explanation
Polydioxanone (PDO) is a synthetic polymer of poly(p-dioxanone) that is presented as a monofilament, which facilitates smooth passage through tissue and reduces the wicking of microorganisms compared with braided multifilament sutures. Its absorption occurs by hydrolysis (not by enzymes), providing a very predictable degradation rate: the suture mass is barely reduced until approximately day 90 and absorption is complete between 180 and 210 days.
Its strength retention profile makes it suitable for slow-healing tissues: it retains approximately 75% of its strength at 2 weeks, 60-70% at 4 weeks and 45% at 8 weeks. The conical-point (Taperpoint) needle separates the fibres without cutting them, minimising tissue damage and making it especially suitable for soft tissues, paediatric cardiovascular tissue and ophthalmic procedures.
3. Technical Specifications
| Material | Polydioxanone (PDO), synthetic monofilament |
| Gauge | USP 3/0 |
| Thread length | 75 cm |
| Needle | ½ circle, cylindrical body, taper point (Taperpoint), 30 mm |
| Colour | Violet |
| Absorption | By hydrolysis, 180-210 days |
| Strength retention | 75% (2 weeks) · 60-70% (4 weeks) · 45% (8 weeks) |
| Sterilisation | Ethylene oxide (EO) |
| Use | Single-use, sterile |
| Presentation | Box of 12 units |
| Manufacturer reference | P412HR3030 (SKU Cahnos: AMP412HR3030) |
| Indications | Approximation of soft tissues, ligatures, general surgery, paediatric cardiovascular tissue and ophthalmology |
4. Equivalences and Cross-References
Polydioxanone is a widely implanted material in the absorbable monofilament suture market. Verified commercial references from the same clinical category are listed below (absorbable polydioxanone monofilament suture, violet, USP 3/0, ½-circle taper-point needle).
| Manufacturer / Brand | Family / Model | Code / SKU | Equivalence level | Technical differences |
|---|---|---|---|---|
| Ethicon (Johnson & Johnson) | PDS II (polydioxanone) | Z316H | Comparable by category (not interchangeable 1:1) | SH ½-circle taper-point needle, 26 mm (vs. 30 mm) and 70 cm thread (vs. 75 cm); box of 36 units. |
| Ethicon (Johnson & Johnson) | PDS II (polydioxanone) | Z774D | Comparable by category (not interchangeable 1:1) | SH ½-circle taper-point needle; 45 cm thread (vs. 75 cm); box of 12 units. |
There is no equivalence table validated by the manufacturer for this reference; consult the technical department before using in a tender. The cited references have been verified in public sources (Ethicon Product Center and authorised distributors), but they present differences in needle/thread geometry or length compared with this suture, so they must be validated against the manufacturer’s technical data sheet before substitution.
5. Selection tips and variants of interest
To choose the appropriate PDO suture, consider three parameters: USP gauge (according to tissue tension), needle geometry (conical Taperpoint point for soft tissues that should not be cut; reverse-cutting triangular for dense tissues or fascia) and needle radius measurement (½ circle for deep spaces and control of the suture point).
In the Cahnos catalogue you will find variants of the same Prime family with conical point: AMP412DR1730 (3/8-circle cylindrical needle 17 mm) and AMP412DR2010 (3/8-circle cylindrical needle 20 mm, USP 0), as well as versions with reverse-cutting triangular needle: AMP412DS2630 (3/8 circle DS26 mm), AMP412DS1930 (DS19 mm) and AMP412DS2430 (DS24 mm), all USP 3/0, 75 cm violet thread. Consult the technical department to confirm the most suitable variant for your procedure.