We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice

Absorbable Monofilament Polydioxanone Suture PDO PDS Prime VisiBlack — ½ Circle Cylindrical Needle Taperpoint Conical Point HR 22 mm · USP 4/0 Gauge · Violet Thread 70 cm · Box of 12 units · Ref. AMP418HR2240VB

65,68 €

Absorbable monofilament suture of polydioxanone (PDO/PDS) Prime VisiBlack with ½ circle needle, cylindrical body and Taperpoint conical point, 22 mm (HR22), USP 4/0 gauge and violet thread 70 cm. Predictable absorption by hydrolysis between 180 and 210 days, with tensile strength retention of 75% at 2 weeks, 60–70% at 4 and 45% at 8. Sterile by ethylene oxide, single-use and minimal tissue reaction; indicated for tissue approximation, ligatures, general surgery, paediatric cardiovascular tissues and Ophthalmology. Presentation in a box of 12 sterile units. Ref. AMP418 (SKU AMP418HR2240VB).

International shipping. Import duties and taxes are payable by the recipient.

Reference
AMP418HR2240VB

Description

1. Commercial Introduction

The absorbable monofilament polydioxanone (PDO/PDS) suture from the Prime VisiBlack range is the reference choice when a suture with prolonged support, predictable behaviour and high knot security is required. This presentation combines a 70 cm violet suture in USP 4/0 gauge with a ½ circle needle with cylindrical body and Taperpoint conical point of 22 mm (HR22), designed to pass through delicate soft tissues with minimal trauma.

Available in a box of 12 sterile units, it is a reliable and cost-effective solution for general surgery departments, paediatric cardiovascular surgery operating theatres, ophthalmology units and hospital purchasing centres seeking consistent quality and full traceability in each pack.

2. Technical Explanation

Polydioxanone is an absorbable synthetic polymer —poly(p-dioxanone)— that degrades by hydrolysis, a mechanism independent of the patient’s enzymatic activity. This ensures highly reproducible absorption kinetics between individuals and minimal tissue response, with complete absorption within 180 to 210 days.

Being a monofilament, the suture has no wicking effect or interstitial spaces: it reduces bacterial adherence, facilitates passage through tissue and minimises the inflammatory reaction compared with braided sutures. The HR22 ½ circle needle with cylindrical body and Taperpoint conical point separates and slides through soft tissue without a cutting effect, a configuration commonly used in delicate tissue approximation, vascular ligatures and planes under sustained tension. The VisiBlack finish optimises the visibility of the violet suture on the surgical field. Sterile single-use product, not re-sterilisable.

3. Technical Specifications

3.1. Technical data sheet for reference AMP418HR2240VB

Parameter Specification
Reference AMP418 (SKU AMP418HR2240VB)
Range / Quality Prime VisiBlack (superior quality)
Material Polydioxanone (PDO/PDS), absorbable synthetic polymer of poly(p-dioxanone)
Thread structure Monofilament, non-braided
USP / metric gauge USP 4/0 (metric 1.5)
Thread length 70 cm
Thread colour Violet (high visibility)
Needle shape ½ circle
Needle body Cylindrical
Needle tip Conical (Taperpoint), atraumatic
Needle size HR22 – 22 mm, one needle per suture
Absorption mechanism Hydrolysis (180–210 days)
Sterilisation Ethylene oxide (EO), single-use, not re-sterilisable
Tissue reaction Minimal
Indications Tissue approximation, ligatures, general surgery, paediatric cardiovascular tissues and ophthalmology
Presentation Box of 12 sterile units

3.2. Tensile strength retention profile

Period after implantation Retained tensile strength
2 weeks 75% of initial strength
4 weeks 60–70% of the initial strength
8 weeks 45% of initial strength
Complete absorption 180–210 days by hydrolysis

This prolonged strength retention profile maintains the necessary support during the critical healing phase of slow-healing tissues, and is therefore recommended for closure of fascia, aponeuroses and structures under sustained traction.

4. Equivalences and Cross-References

Monofilament polydioxanone is the material basis of the market reference lines for long-lasting absorbable sutures (PDS-type family). Based on the verified configuration of this data sheet (½ circle cylindrical needle with conical point of 22 mm, USP 4/0 gauge, 70 cm violet suture), the following references from another manufacturer, comparable at category level and not interchangeable 1:1, have been cross-checked in primary sources (official manufacturer catalogue and authorised distributors):

Manufacturer / Brand Family / Model Reference code / SKU Equivalence level Technical differences / Remarks
Ethicon (Johnson & Johnson MedTech) PDS II® — violet monofilament polydioxanone, SH-1 needle (½ circle, conical point, 22 mm), USP 4/0 gauge, 70 cm suture Z310H Comparable by category (not interchangeable 1:1) Confirmed on the manufacturer’s code page (Ethicon) and authorised distributors: the polymer (PDO monofilament), USP 4/0 gauge, needle geometry and size (SH-1 conical 22 mm, ½ circle), suture length (70 cm / 27″) and violet colour all match; the presentation (box of 36 units vs 12) and the declared strength retention profile differ.
Ethicon (Johnson & Johnson MedTech) PDS Plus® — monofilament polydioxanone with triclosan antibacterial coating, SH-1 needle (½ circle, conical point, 22 mm), USP 4/0 gauge, 70 cm suture PDP310H Comparable by category (not interchangeable 1:1) Same polymer, same USP 4/0 gauge, same SH-1 22 mm needle and same suture length (70 cm); the triclosan antibacterial coating, absent in this reference, and the presentation (box of 36 units vs 12) differ.

There is no equivalence table validated by the manufacturer for this reference against third-party brands; consult the technical department before use in tenders. As homologous market families to verify code by code before substitution: the PDS II® and PDS Plus® lines from Ethicon, the MonoPlus® line from B. Braun/Aesculap (monofilament polydioxanone) and the Surgicryl® PDO line from SMI. All must be checked in their official technical data sheet: USP gauge, suture length, colour, curvature, body, point and needle size. The brands cited belong to their respective manufacturers and are mentioned solely for comparative reference.

5. Selection tips and variants of interest

When choosing a PDO suture, always check the USP gauge according to the tissue plane: fine gauges (4/0 to 6/0) for skin, subcutaneous tissue and delicate tissues, 3/0 and 2/0 for general soft tissue, and USP 1 and above for fascia, aponeuroses and planes under sustained tension. The needle shape is also decisive: the conical point (HR) is indicated for delicate and well-perfused tissues (vessels, parenchyma), the trocar point (HRT) is reserved for firmer tissues and the reverse cutting triangular point (HS) for fibrous tissues.

In the Cahnos catalogue you will find the PDO/PDS family in other gauges, needle sizes and presentations (HR 22 mm in 2/0 and 3/0, HR 36 mm in USP 1, HR 40 mm in 2/0, double needle and ⅝ circle format), always in boxes of 12 units. As this is sterile single-use material, check the integrity of the packaging before each procedure, respect the expiry date and keep the reference and batch number for traceability in the operating theatre. Store in a cool, dry place below 30 °C and protected from sunlight. For special B2B conditions by volume, hospital supply agreements or validation of equivalents from other commercial houses, contact the technical-commercial team at Cahnos.

Additional information

Reference

AMP418 (SKU AMP418HR2240VB)

Quality range

Prime VisiBlack

Material

Polydioxanone (PDO/PDS), synthetic monofilament of poly(p-dioxanone)

USP size

4/0 (metric 1.5)

Needle body

Cylindrical

Needle tip

Conical (Taperpoint), atraumatic

Needle size

HR22 – 22 mm, one needle per suture

Absorption mechanism

Hydrolysis

Sterilisation

Ethylene oxide (EO)

Presentation

Box of 12 sterile units

Use

Single-use, not re-sterilisable

Indications

Tissue approximation, ligatures, general surgery, paediatric cardiovascular tissues and ophthalmology

Medida de aguja

HR 22

Usp

4/0

Color

Violet

Medida de hilo

70 cm

Tipo de aguja

Cylindrical

Forma de aguja

1/2 circle

Calidad sutura

Prime

Absorcion

Slow absorbable (> 120 days)

Reviews

There are no reviews yet.