We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice

Absorbable Monofilament Polydioxanone Suture PDO/PDS | Needle ½ Circle Cylindrical Body Taperpoint Conical Point HR13 (13 mm) | USP 4/0 (Metric 1.5) | Violet Thread 70 cm | Sterile EO | Box of 12 units | Ref. 418HR1340

37,94 €

Absorbable monofilament polydioxanone (PDO/PDS) suture mounted on an atraumatic ½-circle needle, cylindrical body and Taperpoint conical point, 13 mm (HR13). USP gauge 4/0 (metric 1.5), violet fluted thread of 70 cm and predictable absorption by hydrolysis in 180–210 days, with tensile strength retention of 75% at 2 weeks, 60–70% at 4 and 45% at 8. Sterilised by ethylene oxide, single-use and minimal tissue reaction; indicated for approximation of delicate tissues, ligatures, general surgery, paediatric cardiovascular tissues and ophthalmology. Price per box of 12 units · Ref. 418HR1340 · SKU AM418HR1340.

International shipping. Import duties and taxes are payable by the recipient.

Reference
AM418HR1340

Description

1. Introduction

The absorbable monofilament polydioxanone (PDO/PDS) suture Ref. 418HR1340 is the long-acting synthetic resorbable solution your operating theatre needs when tissue requires prolonged tensile support and fully predictable resorption. Manufactured from a next-generation poly(p-dioxanone) polymer, it offers excellent initial tensile strength, smooth passage through tissue and high knot security.

This presentation incorporates an atraumatic ½-circle needle with cylindrical body and 13 mm Taperpoint conical point (HR13), USP 4/0 gauge (metric 1.5), 70 cm violet fluted thread, in a professional 12-unit box format, designed for stock management in operating theatres, hospitals and purchasing centres, with special B2B conditions for volume buyers.

2. Technical explanation

Polydioxanone (PDO) is a synthetic absorbable polymer presented in monofilament structure: a single smooth strand with no bacterial anchoring zones, very low memory, excellent handling and smooth glide through tissue. As it has no wicking effect or capillarity, it reduces bacterial adherence compared with multifilament and minimises the inflammatory response, making it the reference configuration when prolonged support is required in tissues under sustained tension.

Its absorption occurs by hydrolysis, a uniform process independent of the patient’s enzymatic activity, with complete absorption between 180 and 210 days. The ½-circle needle, cylindrical body and conical point (Taperpoint geometry) of 13 mm separates the fibres without cutting effect: it is the most atraumatic configuration for delicate and well-perfused tissues (vessels, parenchyma, friable tissues), with controlled passage and minimal injury along the penetration path, making it suitable for paediatric cardiovascular surgery, ophthalmology and subcutaneous planes. The fluted violet colour ensures optimal visibility on the surgical field. The product is sterilised by ethylene oxide (EO), is single-use and cannot be re-sterilised.

3. Technical Specifications

3.1. Technical data sheet of the reference

Parameter Specification
Reference (SKU) AM418HR1340
Factory reference 418HR1340
Suture type Synthetic absorbable monofilament
Composition Polydioxanone (PDO/PDS), polymer of poly(p-dioxanone)
Thread structure Grooved monofilament
USP / metric gauge 4/0 (metric 1.5)
Thread diameter 0.15 – 0.199 mm (USP/EP standard)
Thread colour Violet (high visibility)
Thread length 70 cm
Needle shape ½ circle (half circumference)
Needle body Cylindrical
Needle tip Conical Taperpoint, atraumatic
Needle size HR13 – 13 mm
Absorption mechanism Hydrolysis
Total absorption 180 – 210 days
Sterilisation Ethylene oxide (EO), sterile, single-use, not re-sterilisable
Tissue reaction Minimal
Indications Tissue approximation, ligatures, general surgery, paediatric cardiovascular tissues and ophthalmology
Presentation Box of 12 units
Regulatory standard USP/EP

3.2. Tensile strength retention and absorption profile

Period after implantation Retained tensile strength
2 weeks 75 % of initial tensile strength
4 weeks 60 – 70 % of the initial tensile strength
8 weeks 45 % of the initial tensile strength
Total absorption 180 – 210 days, by hydrolysis

Predictable and controlled absorption profile, with minimal tissue reaction, excellent tensile strength and optimal knot tying. Price per box of 12 units.

4. Equivalences and Cross-References

Monofilament polydioxanone is the most well-established long-acting absorbable raw material in surgical practice (classic ‘PDS-type’ family), with hydrolysis absorption of 180–210 days and tensile strength retention of 75/60–70/45 % at 2/4/8 weeks. For the verified configuration of this technical data sheet (½-circle cylindrical needle with 13 mm Taperpoint conical point, USP 4/0 gauge, 70 cm violet thread), the following commercial references from other manufacturers have been verified against primary sources (official manufacturer data sheet, GUDID database and authorised distributors):

Manufacturer / Brand Family / Model Reference Code / SKU Equivalence Level Technical Differences / Remarks
Ethicon (Johnson & Johnson MedTech) PDS® Plus (polydioxanone with triclosan), violet, 4/0, 70 cm, needle RB-1 ½ circle of 17 mm PDP304H Comparable by category (not interchangeable 1:1) Same base material PDO monofilament, same USP 4/0 gauge and 70 cm length; the needle radius differs (RB-1 of 17 mm vs HR13 of 13 mm) and it incorporates antimicrobial triclosan coating. Confirmed in official product data sheet and authorised distributor.
Ethicon (Johnson & Johnson MedTech) PDS® II (polydioxanone) monofilament violet, 4/0, 70 cm, needle SH ½ circle conical of 26 mm Z315H Comparable by category (not interchangeable 1:1) Same PDO polymer, USP 4/0 gauge and 70 cm thread, but SH needle of 26 mm vs HR13 of 13 mm; conical point geometry in both cases. Confirmed in official manufacturer source.

There is no equivalence table validated by the manufacturer for this specific reference; consult the technical department before use in tenders. The indicated correspondences are functional comparisons at category level: for a formal substitution of references (same USP 4/0 gauge, HR 13 needle of 13 mm, 70 cm thread) it is essential to confirm the exact coding with each commercial house, verifying material, gauge, needle geometry (shape, body, point and size), strand length and presentation in the manufacturer’s technical data sheet or IFU. Other homologous polydioxanone lines on the market (e.g. Surgicryl® Monofilament PDO from SMI, DemeDIOX® from DemeTECH or MonoPlus® from B. Braun) require case-by-case verification of the exact code for the combination USP 4/0 + 13 mm cylindrical needle + 70 cm.

5. Selection tips and variants of interest

USP 4/0 gauge (metric 1.5) is a fine gauge that combines sufficient tensile strength with a reduced diameter (0.15 – 0.199 mm), indicated for delicate tissues, subcutaneous planes, precision approximations, ligation of small-calibre vessels and paediatric or ophthalmological procedures, where reliable support is required during the first weeks of healing with minimal tissue injury. The ½-circle needle with 13 mm Taperpoint conical point is the most atraumatic option for soft and friable tissues and for reduced-radius access; if a greater penetration arc is required, 17 or 26 mm needles from the same PDO family may be considered.

Variants from the same Cahnos catalogue (same PDO/PDS family, HR 13 mm needle, 70 cm violet thread): AM418HR1310 (USP 0), AM418HR1320 (USP 2/0), AM418HR1330 (USP 3/0) and AM418HR1350 (USP 5/0), for profiles of larger or smaller gauge depending on the tissue; AMP418HR1340, same configuration in Prime quality for higher performance requirements; AM418HR1740-2, double-needle HR17 version in USP 4/0 for continuous sutures with anchoring at both ends; and AM418HRT2630, trocar point (Tapercut) HRT26 version for more resistant tissues. Medium-absorption alternatives (PGA or polyglactin 910, 60–90 days) are also available with the same needle and gauge when such prolonged support is not required.

All references are supplied in boxes of 12 units. As this is sterile single-use material, check the integrity of the packaging before each procedure, respect the expiry date and store it in a cool, dry place, protected from sunlight. For special volume B2B conditions, hospital supply contracts or equivalences from other commercial houses, contact our technical-commercial team.

Additional information

Manufacturer reference

418HR1340

Suture type

Synthetic absorbable monofilament

Material

Polydioxanone (PDO/PDS), polymer of poly(p-dioxanone)

Thread structure

Grooved monofilament

Metric gauge (EP)

1.5

Thread diameter

0.15 – 0.199 mm (USP/EP standard)

Thread colour

Violet (high visibility)

Needle body

Cylindrical

Needle tip

Conical Taperpoint, atraumatic

Needle size

13 mm (HR13)

Absorption mechanism

Hydrolysis

Sterilisation

Ethylene oxide (EO), sterile, single-use, not re-sterilisable

Tissue reaction

Minimal

Indications

Tissue approximation, ligatures, general surgery, paediatric cardiovascular tissues and ophthalmology

Presentation

Box of 12 units

Regulatory standard

USP/EP

Medida de aguja

HR 13

Usp

4/0

Color

Violet

Medida de hilo

70 cm

Tipo de aguja

Cylindrical

Forma de aguja

1/2 circle

Calidad sutura

Normal

Absorcion

Slow absorbable (> 120 days)

Reviews

There are no reviews yet.

Be the first to review “Absorbable Monofilament Polydioxanone Suture PDO/PDS | Needle ½ Circle Cylindrical Body Taperpoint Conical Point HR13 (13 mm) | USP 4/0 (Metric 1.5) | Violet Thread 70 cm | Sterile EO | Box of 12 units | Ref. 418HR1340”

Your email address will not be published. Required fields are marked *