We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice

Absorbable Monofilament Polydioxanone Suture PDO/PDS · Needle ½ Circle Cylindrical Body Taper Point Taperpoint HR36 (36 mm) · USP Size 0 (Metric 3.5) · Violet Thread 90 cm · Box 12 units · Ref. P413HR3610

36,75 €

Absorbable monofilament Polydioxanone (PDO/PDS) suture with a ½ circle needle, cylindrical body and taper point Taperpoint, 36 mm (HR36), USP size 0 (metric 3.5) and violet thread 90 cm. Predictable absorption by hydrolysis in 180-210 days, with tensile strength retention of 75% at 2 weeks, 60-70% at 4 weeks and 45% at 8 weeks. Sterile by ethylene oxide, single-use and minimal tissue reaction; indicated for tissue approximation, ligatures, general surgery, paediatric cardiovascular tissues and ophthalmology. Factory ref. P413HR3610 · SKU AMP413HR3610 · presentation in a box of 12 units.

International shipping. Import duties and taxes are payable by the recipient.

Reference
AMP413HR3610

Description

1. Product Presentation

The absorbable monofilament polydioxanone (PDO/PDS) suture is the reference choice when prolonged absorption, predictable behaviour and maximum security in knot tying are required. This presentation combines a ½ circle needle with cylindrical body and Taperpoint conical point of 36 mm (HR36), USP 0 gauge (metric 3.5) and a 90 cm violet thread, designed to pass through soft tissues with minimal trauma.

Available in a box of 12 sterile units, it is a reliable and cost-effective solution for general surgery departments, paediatric cardiovascular surgery operating theatres, ophthalmology units, and hospital B2B purchasing and supply centres that demand consistent quality and full traceability in every package. Factory reference P413HR3610 (SKU AMP413HR3610).

2. Technical Explanation

Polydioxanone is a synthetic absorbable polymer —poly(p-dioxanone)— with a monofilament structure that degrades by hydrolysis, i.e., by scission of the polymer chains in contact with organic fluids, over a predictable period of 180 to 210 days and independent of the patient’s enzymatic activity. This highly reproducible absorption kinetics between individuals guarantees minimal tissue response.

Being a monofilament, the thread has a smooth surface that reduces friction when passing through tissue, minimises the sawing effect and hinders bacterial adherence compared with braided multifilaments, while maintaining high tensile strength and reliable knot tying during the critical phases of healing. The ½ circle needle with cylindrical body and Taperpoint conical point separates fibres without a cutting effect, making it especially atraumatic in delicate structures such as vessels, parenchyma, paediatric cardiovascular tissue and ocular tissue. The violet colour ensures optimal visibility on the surgical field. The product is sterilised by ethylene oxide, is single-use and cannot be re-sterilised.

3. Technical Specifications

3.1. General characteristics

Parameter Specification
Factory reference P413HR3610
SKU Cahnos AMP413HR3610
Material Polydioxanone (PDO/PDS), poly(p-dioxanone) synthetic monofilament
Thread structure Monofilament
Gauge USP 0 (metric 3.5)
Thread colour Violet (high surgical visibility)
Thread length 90 cm
Needle shape ½ circle (half circumference)
Needle body Cylindrical
Tip type Taperpoint conical (atraumatic)
Needle size HR36 – 36 mm
Absorption mechanism Hydrolysis, 180-210 days
Sterilisation Ethylene oxide (EO), single-use, not re-sterilisable
Tissue reaction Minimal
Indications Tissue approximation, ligatures, general surgery, paediatric cardiovascular tissues and ophthalmology
Presentation Box of 12 sterile units

3.2. Tensile strength retention profile

Period after implantation Retained tensile strength
2 weeks 75 %
4 weeks 60-70 %
8 weeks 45 %
Complete absorption 180-210 days by hydrolysis, with minimal tissue reaction

This prolonged strength retention profile maintains the necessary support during the critical healing phase of slow-recovering tissues, so its use is recommended in closures of fascia, aponeurosis and structures subjected to sustained tension.

4. Equivalences and Cross-References

Monofilament polydioxanone is the most established synthetic absorbable suture raw material with prolonged absorption on the market (PDS-type family). There is no official equivalence table validated by the manufacturer declaring a 1:1 correspondence with other brands; the verified reference indicated below is comparable at category level, not interchangeable point by point, and must be checked field by field (material, gauge, length, colour, curvature, needle size and point) before any substitution.

Manufacturer / Brand Family / Model Reference code / SKU Equivalence level Technical differences / Remarks
Ethicon (Johnson & Johnson MedTech) PDS II® – violet monofilament polydioxanone, USP 0, CT-1 ½ circle needle with conical point of 36 mm, thread 27″ (70 cm) Z340H Comparable by category (not interchangeable 1:1) Confirmed in the official Ethicon catalogue and authorised distributors: material (violet monofilament PDO), USP 0 gauge, needle geometry and size (½ circle, conical point, 36 mm) coincide. They differ in thread length (70 cm vs. 90 cm), presentation (box of 36 units vs. 12) and declared absorption profile (182-238 days in PDS II vs. 180-210 days).

There is no equivalence table validated by the manufacturer for cross-brand matching in the exact configuration of HR36 conical needle of 36 mm with 90 cm thread and USP 0 gauge; consult the technical department before use in tenders. As homologous market families to verify in their official data sheet before any substitution, the PDS II® and PDS Plus® lines from Ethicon, the MonoPlus® line from B. Braun/Aesculap (monofilament polydioxanone, round body needles HR series), the Surgicryl® PDO line from SMI and the Maxon line from Medtronic are cited, checking reference by reference the material, USP 0 gauge, ½ circle curvature, 36 mm needle size, conical point, 90 cm length and violet colour. The cited brands belong to their respective manufacturers and are mentioned only as comparative reference.

5. Selection tips and variants of interest

USP 0 gauge (metric 3.5) is highly versatile: suitable for deep subcutaneous tissue, muscle planes, fascia closure, abdominal wall, approximation of slow-healing tissues and ligation of medium-calibre vessels. The ½ circle Taperpoint conical point HR36 needle ensures atraumatic entry into delicate tissues; if greater penetration into firm or slightly fibrous tissues is required, consider the trocar point (Tapercut) versions of the same family. If healing is 2 to 4 weeks, consider the PGA or PGCL families from the same catalogue.

Reference Variant of interest
AMP413HR3610.2 (P413HR3610.2) PDO Prime, same HR36 needle of 36 mm, USP 0 gauge, 2 threads of 90 cm violet (high-yield double thread format)
AMP412HR3610 (P412HR3610) Standard PDO, same HR36 needle of 36 mm, USP 0 gauge, 75 cm violet thread (shorter format)
AMP413HR3601 (P413HR3601) Standard PDO, same HR36 needle of 36 mm, USP 1 gauge, 90 cm thread (higher initial strength)
AMP418HR3601 Standard PDO, HR36 needle of 36 mm, USP 1 gauge, 70 cm thread (shorter length)
AMP413HR4810 PDO Prime, conical HR48 needle of 48 mm, USP 0 gauge, 90 cm thread (longer needle for deep planes)

As this is sterile single-use material, check the integrity of the packaging before each procedure, respect the expiry date and store the suture in a cool, dry place, protected from sunlight. For special B2B conditions by volume, hospital supply contracts or validation of equivalences with other commercial brands, contact our technical-commercial team at Cahnos.

Additional information

Manufacturer reference

P413HR3610

Material

Polydioxanone (PDO/PDS), synthetic monofilament of poly(p-dioxanone)

Gauge

USP 0 (metric 3.5)

Needle body

Cylindrical

Needle tip

Taperpoint conical (atraumatic)

Needle size

HR36 (36 mm)

Absorption mechanism

Hydrolysis

Sterilisation

Ethylene oxide (EO), single-use, not re-sterilisable

Indications

Tissue approximation, ligatures, general surgery, paediatric cardiovascular tissues and ophthalmology

Presentation

Box of 12 sterile units

Medida de aguja

HR 36

Usp

0

Color

Violet

Medida de hilo

90 cm

Tipo de aguja

Cylindrical

Forma de aguja

1/2 circle

Calidad sutura

Normal

Estructura hilo

Monofilament

Absorcion

Slow absorbable (> 120 days)

Tipo uso

Single-use

Reviews

There are no reviews yet.

Be the first to review “Absorbable Monofilament Polydioxanone Suture PDO/PDS · Needle ½ Circle Cylindrical Body Taper Point Taperpoint HR36 (36 mm) · USP Size 0 (Metric 3.5) · Violet Thread 90 cm · Box 12 units · Ref. P413HR3610”

Your email address will not be published. Required fields are marked *