Description
1. Product Presentation
The absorbable monofilament polydioxanone (PDO/PDS) suture is the reference technical choice when the tissue needs prolonged support during healing and fully predictable reabsorption. This presentation combines a 75 cm violet grooved thread in USP 3/0 gauge with a ½ circle needle, cylindrical body and conical point (Taperpoint) of 22 mm (HR22), designed to pass through soft, well-perfused tissues with the least possible trauma.
Available in a box of 12 sterile units, it is a reliable and cost-effective solution for general surgery departments, paediatric cardiovascular surgery operating theatres, ophthalmology units and hospital purchasing centres seeking quality homogeneity with CE marking.
2. Technical Explanation
Polydioxanone is a synthetic absorbable polyester —a polymer of poly(p-dioxanone)— that degrades by hydrolysis, a mechanism independent of the patient’s enzymatic activity that ensures highly reproducible absorption kinetics between individuals. It has the longest absorption profile among conventional synthetic absorbable sutures, making it suitable for slow-healing tissues or those under sustained tension.
Being a monofilament, the thread has no wicking effect or capillary edges, which reduces bacterial adherence, facilitates sliding through tissue and minimises the inflammatory response compared with multifilaments. Its firm feel and excellent knotting capacity make it suitable for ligatures and sutures of planes under sustained tension.
The ½ circle needle with cylindrical body and conical Taperpoint point separates and slides through soft tissue without cutting effect, being especially atraumatic in delicate structures such as vessels, parenchyma, paediatric cardiovascular tissue and ocular tissue. The grooved violet colour improves thread visibility on the surgical field. It is supplied sterile by ethylene oxide, single-use and with no possibility of re-sterilisation.
3. Technical Specifications
3.1. General characteristics
| Parameter | Specification |
|---|---|
| Material | Polydioxanone (PDO/PDS), synthetic absorbable monofilament polymer – poly(p-dioxanone) |
| Thread structure | Grooved monofilament |
| Gauge | USP 3/0 (metric EP 2) |
| Thread length | 75 cm |
| Thread colour | Violet (high visibility) |
| Swaged | 1 needle per suture |
| Needle shape | ½ circle (half circumference), cylindrical body |
| Tip type | Conical Taperpoint (atraumatic) grooved |
| Needle size | HR22 – 22 mm |
| Absorption mechanism | Hydrolysis; complete absorption between 180 and 210 days |
| Sterilisation | Ethylene oxide (EO); single-use, not re-sterilisable |
| Tissue reaction | Minimal, with excellent tensile strength and knot tying |
| Indications | Tissue approximation, ligatures, general surgery, fascia, paediatric cardiovascular tissues and ophthalmology |
| Presentation | Box of 12 sterile units |
| Factory reference / SKU | 412HR2230 / AM412HR2230 |
3.2. Tensile strength retention profile
| Period after implantation | Tensile strength retention |
|---|---|
| 2 weeks | 75 % |
| 4 weeks | 60–70 % |
| 8 weeks | 45 % |
| Complete absorption | 180–210 days by hydrolysis, with minimal tissue reaction |
This prolonged force retention profile is maintained during the critical healing phase of slow-healing tissues, so its use is recommended in closures of fascia, aponeurosis and structures under sustained traction.
4. Equivalences and Cross-References
Monofilament polydioxanone is the material basis of the market reference lines for long-lasting absorbable sutures (PDS type). There is no official equivalence table validated by the manufacturer declaring a 1:1 correspondence with other brands; the verified reference indicated below is comparable at category level, not interchangeable point by point, and must be checked field by field (material, gauge, length, colour, curvature, needle size and point) before any substitution.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
|---|---|---|---|---|
| B. Braun (Aesculap) | MonoPlus® – uncoated monofilament polydioxanone, violet, USP 3/0 (EP 2), 70 cm, HR22 needle of 22 mm (½ circle, round body, conical point) | C0024135 – MONOPLUS VIOLET 3/0 (2) 70CM HR22 (verified in official catalogue B. Braun) | Comparable by category (not interchangeable 1:1) | They match in material (polydioxanone), USP 3/0 gauge (EP 2), ½ circle curvature, conical point family, HR22 needle size of 22 mm and violet colour; they differ in thread length (70 cm vs 75 cm). Confirm IFU and CE/MDR classification before substituting. |
There is no equivalence table validated by the manufacturer that officially cross-references this reference with the commercial series of other brands; consult the technical department before use in tenders. As homologous market families to verify code by code before substitution: the PDS II® and PDS Plus® lines from Ethicon (the latter with antibacterial triclosan coating, indicated only where its use is approved), the MonoPlus® line from B. Braun/Aesculap (violet polydioxanone monofilament), the Surgicryl PDO line from SMI and the Maxon line from Medtronic/Covidien. All must be checked in their official technical data sheet (USP gauge, thread length, colour, curvature, body, point and needle size). The cited brands belong to their respective manufacturers and are mentioned only as comparative reference.
5. Selection tips and variants of interest
When choosing a PDO suture, always check the USP gauge according to the tissue plane: fine gauges (4/0 to 6/0) for skin and subcutaneous tissue, 3/0 and 2/0 for general soft tissue —as is the case with this reference— and USP 0 and above for fascia and planes under tension. Needle geometry is also decisive: the conical point (HR) is indicated for delicate, well-perfused tissues (vessels, parenchyma), while the trocar point (HRT) is reserved for firmer tissues and the reverse cutting triangular point (HS) for fibrous tissues.
Within the Cahnos catalogue, the PDO/PDS family of ½ circle with conical point includes variants of interest: AM412HR2630 (HR26 needle of 26 mm, USP 3/0, 75 cm) for tissues of greater consistency; AM412HR2240 (HR22 needle, USP 4/0, 75 cm) for finer tissues; AMP412HR2230 (same HR22 USP 3/0 configuration in the Prime range); AM418HR2230-2 (double HR22 needle, USP 3/0, 70 cm) for continuous sutures; and AM413HR4810 (HR48 needle, USP 0, 90 cm) for deep planes. Always check the USP gauge, needle size and geometry against your surgical protocol before substituting one reference for another.
As it is sterile single-use material, check the integrity of the packaging before each procedure, respect the expiry date and store the suture in a cool, dry place, protected from sunlight. For special B2B conditions, volume orders or other gauges, lengths and colours on request, contact the technical-commercial team at Cahnos.





Reviews
There are no reviews yet.