Description
1. Product Presentation
The absorbable monofilament polydioxanone (PDO/PDS) suture is the reference technical choice when the tissue needs prolonged support during healing and fully predictable reabsorption. This presentation combines a 75 cm violet grooved thread in USP 3/0 gauge with a ½ circle needle, cylindrical body and taperpoint conical point of 26 mm (HR26), configured to pass through soft, well-perfused tissues with the least possible trauma. Available in a box of 12 units, it is a reliable and cost-effective solution for general surgery departments, paediatric cardiovascular surgery operating theatres, ophthalmology units and hospital purchasing centres seeking consistent quality with CE marking.
2. Technical Explanation
Polydioxanone is an absorbable synthetic polyester —a poly(p-dioxanone) polymer— that degrades by hydrolysis, a mechanism independent of the patient’s enzymatic activity that guarantees a highly reproducible absorption kinetics between individuals. Being a monofilament, the thread has no wicking effect or capillary edges, which reduces bacterial adherence, facilitates sliding through tissue and minimises the inflammatory response compared with multifilaments. Its firm feel and excellent knotting capacity make it ideal for ligatures and sutures of planes subjected to sustained tension.
The ½ circle needle (half-circumference curvature) with cylindrical body and taperpoint conical point separates and slides through soft tissue with minimal injury, indicated for tissue approximation, ligatures, general surgery, paediatric cardiovascular tissue and ophthalmology. The USP 3/0 gauge (metric 2) offers an optimal balance between strength and delicacy for subcutaneous tissue, superficial muscle planes and slow-healing soft tissues. The grooved violet colour improves thread visibility over the surgical field. It is supplied sterile by ethylene oxide, single-use and with no possibility of re-sterilisation.
3. Technical Specifications
3.1. General characteristics
| Material | Polydioxanone (PDO/PDS), absorbable synthetic monofilament polymer |
| Thread structure | Grooved monofilament |
| Gauge | USP 3/0 (metric 2) |
| Thread length | 75 cm |
| Thread colour | Violet (high visibility) |
| Needle shape | ½ circle (half circumference) |
| Needle body and point | Cylindrical, taperpoint conical point |
| Needle size | HR26 – 26 mm |
| Absorption mechanism | Hydrolysis (180–210 days) |
| Sterilisation | Ethylene oxide (single-use, not re-sterilisable) |
| Tissue reaction | Minimal, with excellent tensile strength and knot tying |
| Indications | Tissue approximation, ligatures, general surgery, fascia, paediatric cardiovascular tissues and ophthalmology |
| Presentation | Box of 12 sterile units |
| Factory reference / SKU | 412HR2630 / AM412HR2630 |
3.2. Tensile strength retention profile
| Time | Tensile strength retention |
| 2 weeks | 75 % |
| 4 weeks | 60–70 % |
| 8 weeks | 45 % |
| Complete absorption | 180–210 days by hydrolysis |
This prolonged force retention profile is maintained during the critical healing phase of slow-healing tissues, which is why its use is recommended in closures of fascia, aponeuroses and structures subjected to sustained traction. It is supplied sterile, ready for use, in individual packaging.
4. Equivalences and Cross-References
Polydioxanone monofilament is the material basis of the market reference lines for long-lasting absorbable sutures (PDS type). On the verified configuration of this technical data sheet (½ circle cylindrical needle with conical point of 26 mm, USP 3/0 gauge, 75 cm violet thread), the following commercial reference from another manufacturer has been compared:
| Manufacturer / Brand | Family / Model | Code / SKU | Equivalence level | Technical differences / Remarks |
| Johnson & Johnson MedTech (Ethicon) | PDS II® (polydioxanone) violet monofilament, CT-2 needle | Z332H | Comparable by category (not interchangeable 1:1) | Same PDO monofilament material, same USP 3/0 gauge, same ½ circle taperpoint conical point needle of 26 mm (CT-2) and violet colour. Difference: thread length of 70 cm versus 75 cm for this reference. Confirmed in Ethicon product data sheet and authorised distributors. |
| Johnson & Johnson MedTech (Ethicon) | PDS II® (polydioxanone) violet monofilament, SH needle | Z316H | Comparable by category (not interchangeable 1:1) | Same material, USP 3/0 gauge, 70 cm violet thread and ½ circle curvature; SH needle of 26 mm taperpoint conical point versus HR26 of this reference, with shorter thread (70 cm versus 75 cm). |
There is no manufacturer-validated equivalence table that officially cross-references this reference with the commercial series of other brands; consult the technical department before use in tenders. As homologous market families to verify code by code before substitution: the PDS II® and PDS Plus® lines from Ethicon (the latter with antibacterial triclosan coating, indicated only where its use is approved), the MonoPlus® line from B. Braun/Aesculap (violet polydioxanone monofilament), the Surgicryl PDO line from SMI and the Maxon line from Medtronic/Covidien. All must be checked in their official technical data sheet (USP gauge, thread length, colour, curvature, body, point and needle size). The cited brands belong to their respective manufacturers and are mentioned only as comparative reference.
5. Selection tips and variants of interest
When choosing a PDO suture, always verify the USP gauge according to the tissue plane: fine gauges (4/0 to 6/0) for skin and subcutaneous tissue, 3/0 and 2/0 for general soft tissue —as is the case with this reference— and USP 0 and above for fascia and planes under tension. The needle shape is also decisive: the conical point (HR) is indicated for delicate, well-perfused tissues (vessels, parenchyma), while the trocar point (HRT) is reserved for firmer tissues and the reverse cutting triangular point (HS) for fibrous tissues.
Within the Cahnos catalogue, the half-circle PDO/PDS family with conical point includes variants of interest: AM412HR1740 (HR17 needle of 17 mm, USP 4/0, 75 cm) for finer tissues; AMP418HR2610 (HR26 needle of 26 mm, USP 0, 70 cm) for tissue planes of greater consistency; AM413HR4810 (HR48 needle of 48 mm, USP 0, 90 cm) for deep sutures; as well as the trocar-point version AM418HRT2630 (HRT26, USP 3/0, 70 cm) for more resistant tissues and the reverse-cutting triangular needle AMP418HS2610 (HS26, USP 0, 70 cm). Always verify the USP gauge, size and needle geometry against your surgical protocol before substituting one reference for another.
As this is sterile single-use material, check the integrity of the packaging before each procedure, respect the expiry date and store the suture in a cool, dry place, protected from sunlight. For special B2B conditions, volume orders or other gauges, lengths and colours made to order, contact the technical-commercial team at Cahnos.