Description
1. Product Presentation
At Cahnos we offer you the absorbable monofilament polydioxanone (PDO/PDS) suture from the Prime range, reference P418HR2220.2 (SKU AMP418HR2220.2), designed for the professional who needs a thread with prolonged absorption, predictable handling and maximum knot security in the approximation of soft tissues and ligatures. This presentation combines a double ½-circle needle with cylindrical body and conical Taperpoint point of 22 mm (HR 22), gauge USP 2/0 and violet fluted thread in format 2×70 cm, supplied in a box of 12 sterile units.
It is the reference solution for B2B supply to operating theatres, general surgery departments, paediatric cardiovascular surgery units, ophthalmology services and purchasing centres. A synthetic absorbable medical device, sterile and single-use, with CE marking and a very competitive price-quality ratio.
2. Technical Explanation
Polydioxanone is a synthetic absorbable polymer —poly(p-dioxanone)— with a monofilament structure that degrades by hydrolysis, i.e., by cleavage of the polymer chains in contact with organic fluids, over a predictable period of 180 to 210 days, independent of the patient’s enzymatic activity. Being a monofilament, the thread has a smooth surface that reduces friction when passing through tissue, minimises the sawing effect and hinders bacterial adherence, while maintaining high tensile strength and reliable knot tying during the critical phases of wound healing.
The ½-circle needle with cylindrical body and fluted conical Taperpoint point separates the fibres without cutting effect, making it especially atraumatic in delicate structures such as vessels, parenchyma, paediatric cardiovascular tissue and ocular tissue. The double-needle format allows continuous sutures or having a needle at both ends for precision techniques. The product is sterilised by ethylene oxide, is single-use and does not allow re-sterilisation.
3. Technical Specifications
3.1. General characteristics
| Parameter | Specification |
|---|---|
| Material | Polydioxanone (PDO/PDS), poly(p-dioxanone) synthetic monofilament |
| Thread structure | Fluted monofilament (not braided) |
| Quality | Prime (range PREMISUT) |
| Gauge | USP 2/0 (metric 3) |
| Thread colour | Violet, high surgical visibility |
| Thread length | 2 threads of 70 cm (2×70 cm) |
| Swaged | Double needle (2 mounted needles) |
| Needle shape | ½ circle (half circumference) |
| Needle body | Cylindrical |
| Tip type | Conical Taperpoint (atraumatic) grooved |
| Needle size | HR 22 – 22 mm |
| Absorption mechanism | Hydrolysis, 180–210 days |
| Sterilisation | Ethylene oxide (EO), single-use, not re-sterilisable |
| Tissue reaction | Minimal, with excellent tensile strength and knot tying |
| Indications | Tissue approximation, ligatures, general surgery, paediatric cardiovascular tissues and ophthalmology |
| Factory reference | P418HR2220.2 |
| SKU Cahnos | AMP418HR2220.2 |
| Presentation | Box of 12 sterile units; each unit contains 2 threads of 70 cm with double needle |
3.2. Tensile strength retention profile
| Period after implantation | Tensile strength retention |
|---|---|
| 2 weeks | 75 % |
| 4 weeks | 60–70 % |
| 8 weeks | 45 % |
| Complete absorption | Between 180 and 210 days by hydrolysis, with minimal tissue reaction |
Excellent tensile strength, optimal knot tying and a fully predictable absorption rate, with prolonged tissue support during the critical healing phase.
4. Equivalences and Cross-References
Monofilament polydioxanone is the most well-established synthetic absorbable suture material with prolonged absorption on the market (PDS-type lines). There is no official equivalence table validated by the manufacturer that declares a 1:1 correspondence with other brands; the verified reference indicated below is comparable at category level, not interchangeable point by point, and must be checked field by field (material, gauge, length, colour, curvature, needle size and point) before any substitution.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
|---|---|---|---|---|
| Ethicon (Johnson & Johnson MedTech) | PDS II® – uncoated monofilament polydioxanone, USP 2/0, violet, 70 cm (27″), CT-2 needle of 26 mm, ½ circle, conical point (taper point) | Z333H | Comparable by category (not interchangeable 1:1) | Confirmed in the official Ethicon catalogue and authorised distributors: they match in material (PDO monofilament), USP gauge 2/0, thread length (70 cm), violet colour, ½-circle curvature and conical point; they differ in needle size (CT-2 26 mm vs HR 22 mm), configuration (1 needle vs double needle) and presentation (box of 36 vs 12 units). |
There is no equivalence table validated by the manufacturer that allows an exact 1:1 cross-reference with the double-needle HR 22 Taperpoint configuration in gauge 2/0; consult the technical department before use in tenders. As homologous families on the market, to be verified reference by reference in their official data sheet before substitution, the following are cited: the PDS II® / PDS Plus® line from Ethicon, the MonoPlus® line from B. Braun (violet monofilament polydioxanone, HR/HR26S needles), the Surgicryl® PDO line from SMI and the Maxon line from Medtronic/Covidien, checking in each case USP gauge 2/0, ½-circle curvature, 22 mm needle size, conical point, 70 cm length, violet colour and double configuration. The cited brands belong to their respective manufacturers and are mentioned only as comparative reference.
5. Selection tips and variants of interest
The USP 2/0 gauge (metric 3) is versatile: suitable for subcutaneous tissue, superficial muscle planes, moderate-tension fascia and approximation of soft tissues, as well as for general, digestive, paediatric cardiovascular surgery and ophthalmology. The ½-circle needle with 22 mm conical Taperpoint point guarantees atraumatic entry into delicate tissues; if greater penetration is required in firm or slightly fibrous tissues, consider the trocar point (Tapercut) versions of the same family (HRT series). The double-needle format (2×70 cm) is especially practical for continuous sutures or techniques requiring two active ends.
Variants of interest in the Cahnos catalogue within the PDO/PDS family of ½-circle conical point:
| Reference | Description |
|---|---|
| AMP418HR2220 | PDO Prime, HR 22 mm conical Taperpoint needle, USP 2/0, violet, 70 cm, single needle (same configuration in single-armed) |
| AMP418HR2210.2 | PDO Prime, double needle HR 22 mm conical point, USP 0, violet, 2×70 cm (larger gauge) |
| AMP418HR2230-2 | PDO Prime, double needle HR 22 mm conical point, USP 3/0, violet, 70 cm (fine gauge for delicate tissue) |
| AMP418HR2240-2 | PDO Prime, double needle HR 22 mm conical point, USP 4/0, violet, 70 cm (finer gauge, greater precision) |
| AMP418RR2610.2 | PDO Prime, double needle HR 26 mm conical Taperpoint point, USP 0, violet, 2×70 cm (longer needle) |
As this is a sterile single-use product, check the integrity of the packaging before each procedure, respect the expiry date and store the suture in a cool, dry place, protected from sunlight. For special B2B conditions by volume, hospital traceability or equivalences with other commercial brands, contact our technical-commercial team at Cahnos.





Reviews