Description
1. Product Presentation
The absorbable monofilament polydioxanone (PDO/PDS) Prime suture is the long-acting synthetic reabsorbable solution your operating theatre needs for procedures where tissue requires prolonged tensile support. Made with next-generation polydioxanone, a polymer composed of poly(p-dioxanone), it offers predictable behaviour, excellent initial tensile strength, smooth passage through tissue and great security in knot tying.
This presentation incorporates an atraumatic ½ circle needle with cylindrical body and conical Taperpoint tip of 13 mm (HR 13), USP 0 gauge (metric 3.5), 70 cm violet thread and Prime quality, in a professional format of a box of 12 units, designed for stock management in operating theatres, hospitals and purchasing centres.
2. Technical explanation of the material and procedure
Polydioxanone (PDO) is a synthetic absorbable polymer presented in a monofilament structure: a single smooth strand with no bacterial anchoring zones, very low memory, excellent handling and smooth sliding through tissue. As it is uncoated, it maintains a uniform surface that reduces drag and minimises tissue reaction, being the reference configuration when long-term support is required in tissues subjected to sustained tension.
Its absorption occurs by hydrolysis, a uniform process independent of the patient’s enzymatic activity, with total absorption between 180 and 210 days: tensile strength retention is maintained at 75% at 2 weeks, 60–70% at 4 weeks and 45% at 8 weeks. The ½ circle needle, cylindrical body and conical tip (Taperpoint geometry) of 13 mm separates fibres without cutting effect: it is the most atraumatic configuration for delicate and friable tissues, with controlled passage and minimal injury along the penetration path, making it ideal for paediatric cardiovascular surgery and ophthalmology. The violet colour ensures optimal visibility on the surgical field. The product is sterilised by ethylene oxide (EO), is single-use and does not allow re-sterilisation.
3. Technical Specifications
3.1. Technical data sheet for reference AMP418HR1310
| Characteristic | Specification |
| Reference (SKU) | AMP418HR1310 |
| Factory reference | P418HR1310 |
| Quality | Prime |
| Suture type | Synthetic absorbable monofilament |
| Composition | Polydioxanone (PDO), polymer of poly(p-dioxanone) |
| Thread structure | Monofilament, non-channeled |
| USP / metric gauge | 0 / 3.5 |
| Thread colour | Violet |
| Thread length | 70 cm |
| Needle shape | ½ circle |
| Needle body | Cylindrical |
| Needle tip | Conical Taperpoint, atraumatic |
| Needle size | 13 mm (HR 13 Prime) |
| Absorption mechanism | Hydrolysis |
| Total absorption | 180–210 days |
| Sterilisation | Ethylene oxide (EO), sterile, single-use |
| Tissue reaction | Minimal |
| Indications | Tissue approximation, ligatures, general surgery, paediatric cardiovascular and ophthalmology |
| Presentation | Box of 12 units |
| Regulatory standard | USP/EP |
3.2. Tensile strength retention and absorption profile
| Period after implantation | Retained tensile strength |
| 2 weeks | 75 % of initial tensile strength |
| 4 weeks | 60–70 % of the initial tensile strength |
| 8 weeks | 45 % of the initial tensile strength |
| Total absorption | 180–210 days, by hydrolysis |
Predictable and controlled absorption profile, with minimal tissue reaction, excellent tensile strength and optimal knot tying. Price per box of 12 units.
4. Equivalences and Cross-References
Monofilament polydioxanone is the most well-established absorbable raw material of long duration in surgical practice (classic ‘PDS’ type family), with hydrolysis absorption of 180–210 days and tensile strength retention of 75/60–70/45% at 2/4/8 weeks. This Prime reference, with cylindrical Taperpoint HR 13 needle of 13 mm, USP 0 gauge and 70 cm thread, is comparable at category level (not interchangeable 1:1) with the following homologous polydioxanone lines from other manufacturers, which use the same polymer and a similar clinical profile:
- SMI (Belgium) – Surgicryl® Monofilament PDO: polydioxanone monofilament, violet, uncoated, approximate total absorption of 180–210 days and ≈50% tensile strength retained at 42 days (verified in the manufacturer’s official catalogue). Box of 12 units.
- Ethicon / Johnson & Johnson MedTech – PDS II®: classic violet monofilament polydioxanone reference, with the same prolonged absorption profile; the exact combination of USP 0 + HR 13 needle + 70 cm must be confirmed code by code with the commercial house.
- DemeTECH (USA) – DemeDIOX®: polydioxanone monofilament suture, violet and colourless, hydrolysis absorption in 180–210 days, available with a ½ circle cylindrical body needle; confirm the exact variant with the manufacturer.
- B. Braun – Monomax®: prolonged absorption monofilament polydioxanone line, with a similar clinical profile; verify the exact reference for the combination USP 0 + 13 mm + 70 cm with the commercial house.
There is no equivalence table validated by the manufacturer; consult the technical department before use in tenders. The indicated correspondences are functional comparisons at category level: for a formal substitution of references (same USP 0 gauge, HR 13 needle of 13 mm, 70 cm thread) it is essential to confirm the exact coding with each commercial house, verifying material, gauge, needle geometry (shape, body, tip and size), strand length and presentation in the manufacturer’s technical data sheet or IFU.
5. Selection tips and variants of interest
USP 0 gauge (metric 3.5) provides high initial tensile strength, indicated for medium-high tension tissues, ligatures of medium-calibre vascular structures, closures of muscle planes and general surgery. The ½ circle needle with conical Taperpoint tip of 13 mm is the most atraumatic option for soft and friable tissues; if a greater penetration arc is required, needles with a larger radius within the same family may be considered.
Variants from the same Cahnos catalogue:
- AM418HR1310: same PDO USP 0 configuration, HR 13 mm needle, violet, 70 cm, in standard quality (factory reference 418HR1310), for cost optimisation.
- AMP418HR1320 / AMP418HR1330 / AMP418HR1340 / AMP418HR1350: same PDO Prime family with HR 13 mm needle in USP 2/0, 3/0, 4/0 and 5/0 gauges, violet, 70 cm, for different tension depending on the tissue.
- AMP418HR1350-2: same Prime family in double HR 13 mm needle, USP 5/0 gauge, for continuous sutures with anchoring at both ends.
- AMP118HR1310: same HR 13 mm needle and USP 0 gauge in multifilament PGA (absorption 60–90 days), as a medium absorption alternative.
- P1L18HR1310: same needle and gauge in polyglactin 910 (PGLA), absorption of 56–72 days, for shorter healing times.
All references are supplied in boxes of 12 units. As this is sterile single-use material, check the integrity of the packaging before each procedure, respect the expiry date and store in a cool, dry place, protected from sunlight. For special B2B conditions by volume, hospital supply contracts or equivalents from other commercial brands, contact our technical-commercial team.