We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice

Absorbable Monofilament Polydioxanone PDO/PDS Prime Suture · ½ Circle Cylindrical Body Needle Blunt Point 45 mm (HRN45) · USP Gauge 1 · Violet Thread 90 cm · Ref. AMP413HRN4501 · Box of 12 units

51,86 €

Absorbable monofilament polydioxanone (PDO/PDS) suture in Prime quality, reference AMP413HRN4501 (manufacturer P413HRN4501), with a ½ circle cylindrical body needle and blunt point 45 mm (HRN45), USP gauge 1 (metric 4) and violet thread 90 cm. Predictable absorption by hydrolysis between 180 and 210 days, with tensile strength retention of 75% at 2 weeks, 60-70% at 4 weeks and 45% at 8 weeks. Sterile by ethylene oxide, single-use, minimal tissue reactivity and excellent knot security. Indicated for tissue approximation, ligatures, general surgery, paediatric cardiovascular tissues and ophthalmology. Presentation in box of 12 units.

International shipping. Import duties and taxes are payable by the recipient.

Reference
AMP413HRN4501

Description

1. Product Presentation

The absorbable monofilament suture of polydioxanone (PDO/PDS) in Prime quality offered by Cahnos, reference AMP413HRN4501 (manufacturer ref. P413HRN4501), is the reference choice for hospitals, private clinics, operating theatres and purchasing centres looking for a long-lasting absorbable synthetic thread with a very competitive price-quality ratio.

This reference combines a ½ circle cylindrical body needle with blunt point (blunt point) of 45 mm (HRN45), USP 1 gauge (metric 4) and violet thread of 90 cm. It is supplied sterile and ready to use, in a box of 12 units. Especially indicated for tissue approximation, ligatures, general surgery, paediatric cardiovascular tissues and ophthalmology, where prolonged wound support is required (tissues that take more than 6 weeks to regain their strength).

2. Technical Explanation

Polydioxanone is an absorbable synthetic polymer (poly(p-dioxanone)) that degrades by hydrolysis, i.e., by contact with organic fluids, with minimal inflammatory response and without depending on the patient’s enzymatic activity. Its monofilament structure facilitates passage through tissue with less friction and eliminates interstitial spaces, which reduces the risk of bacterial colonisation compared to braided threads.

The ½ circle needle with cylindrical body and blunt point offers an atraumatic entry into soft tissues, separating the fibres without cutting them and minimising tissue damage, making it ideal for delicate structures and reduced surgical fields. The USP 1 gauge (metric 4) provides high initial strength, suitable for fascia, aponeurosis, muscle planes and closures with moderate-high tension. The violet colouring guarantees optimal visibility of the thread throughout the procedure. Sterile single-use product, not re-sterilisable.

3. Technical Specifications

3.1. Technical data sheet for reference AMP413HRN4501

Characteristic Specification
Reference (SKU) AMP413HRN4501 (manufacturer ref. P413HRN4501)
Range / Quality Prime line
Material Polydioxanone (PDO/PDS), synthetic monofilament
Gauge USP 1 (metric 4)
Thread colour Violet (high visibility)
Thread length 90 cm
Needle shape ½ circle (1/2)
Needle body Cylindrical
Needle tip Blunt point (blunt point)
Needle size 45 mm (HRN45)
Absorption mechanism Hydrolysis
Absorption period 180-210 days
Sterilisation Ethylene oxide (EO), sterile, single-use
Tissue reaction Minimal
Indications Tissue approximation, ligatures, general surgery, paediatric cardiovascular tissues and ophthalmology
Presentation Box of 12 units

3.2. Tensile strength retention profile

Time after implantation Retained tensile strength
2 weeks 75 %
4 weeks 60-70 %
8 weeks 45 %

Complete absorption by hydrolysis between 180 and 210 days. Minimal tissue reaction, excellent tensile strength and optimal knot tying, with a completely predictable absorption rate.

4. Equivalences and Cross-References

Polydioxanone monofilament is a family of long-lasting absorbable sutures that is clinically comparable with the main lines on the international market. Below are listed references from other commercial houses verified against the manufacturer’s official catalogue, in the configuration closest to the analysed reference (USP 1, ½ circle needle of 45 mm, violet thread of 90 cm):

Manufacturer / Brand Family / Model Reference Code / SKU Equivalence Level Technical Differences / Remarks
B. Braun MonoPlus (polydioxanone) – Needle ½ circle round body HRN45 of 45 mm, blunt point, USP 1, violet, 90 cm C0024406 Comparable by category (not interchangeable 1:1) Same material (PDO), same USP 1 gauge, same needle geometry (½ circle, round body, blunt point of 45 mm, identical needle code HRN45) and violet thread of 90 cm. Declared absorption profile comparable (long lasting). Code verified in official catalogue B. Braun; confirm batch and regulatory classification before substituting.
Ethicon (Johnson & Johnson MedTech) PDS II (polydioxanone) – Needle ½ circle V-39 of 45 mm, trocar point (Tapercut), USP 1, violet, 90 cm W9385T Comparable by category (not interchangeable 1:1) Same material (PDO), same USP 1 gauge, same needle measurement (45 mm) and violet thread of 90 cm; differs the type of point (trocar Tapercut versus blunt point of the analysed reference). Code present in the official Ethicon catalogue of the PDS II line.
Ethicon (Johnson & Johnson MedTech) PDS Plus (polydioxanone with triclosan) – Needle ½ circle V-39 of 45 mm, trocar point (Tapercut), USP 1, violet, 90 cm PDP9385H Comparable by category (not interchangeable 1:1) Same material (PDO), same USP 1 gauge, same needle measurement (45 mm) and violet thread of 90 cm; differ the type of point (trocar versus blunt point) and incorporates antimicrobial coating of triclosan (PDS Plus). Code verified in authorised distribution.

There is no equivalence table validated by the manufacturer for cross-referencing between brands in the exact configuration of blunt point needle HRN45 of 45 mm with USP 1 gauge and 90 cm thread; consult with the technical department before using in tender. For any formal substitution, the material, gauge (USP 1), needle measurement and geometry (½ circle, cylindrical body, blunt point, radius 45 mm), thread length (90 cm), colour and regulatory classification of each reference must be verified one by one, since small variations in needle radius or point profile prevent a 1:1 equivalence. Within the same clinical category, the reference prolonged absorption monofilament polydioxanone lines in the sector also include PDS II and PDS Plus from Ethicon and MonoPlus from B. Braun, comparable at category level and not interchangeable 1:1.

5. Selection tips and variants of interest

The USP 1 gauge (metric 4) is very versatile: suitable for subcutaneous tissue, muscle planes, fascia closure, abdominal wall and soft tissue approximation with moderate-high tension. The blunt point offers an atraumatic entry ideal for soft tissues and delicate structures; if the procedure requires greater penetration in firm or fibrous tissues, consider a conical or trocar point needle (Tapercut) from the same family and gauge. Within the PDO family of Cahnos, the following variants of interest are available:

Reference Recommended variant
AM413HRN4501 PDO USP 1, Blunt point needle HRN45 of 45 mm, violet, 90 cm (same configuration, standard quality)
AMP413HR4010 PDO Prime USP 0, conical needle HR 40 mm, violet, 90 cm (smaller gauge and conical point)
AMP413HRP4010 PDO Prime USP 0, conical needle Ultra Plus HRP 40 mm, violet, 90 cm (smaller gauge, different point profile)
AMP413HRP4001 PDO Prime USP 1, conical needle Ultra Plus HRP 40 mm, violet, 90 cm (same gauge, shorter needle and conical point)
AMP413HRP4801 PDO Prime USP 1, conical needle Ultra Plus HRP 48 mm, violet, 90 cm (same gauge, longer needle)

All references are supplied in boxes of 12 units. As this is a sterile single-use product, check the integrity of the packaging before each procedure, respect the expiry date and store the suture in a cool, dry place, protected from sunlight. For special B2B conditions by volume, hospital supply contracts or equivalences with other commercial brands, contact our technical-commercial team.

Additional information

Material

Polydioxanone (PDO/PDS), synthetic monofilament

Gauge

USP 1 (metric 4)

Needle body

Cylindrical

Needle tip

Blunt point (blunt point)

Needle size

45 mm (HRN45)

Absorption mechanism

Hydrolysis

Sterilisation

Ethylene oxide (EO)

Presentation

Box of 12 units

Manufacturer reference

P413HRN4501

Medida de aguja

HRN 45

Usp

1

Color

Violet

Medida de hilo

90 cm

Tipo de aguja

Blunt tip

Forma de aguja

1/2 circle

Calidad sutura

Prime

Absorcion

Slow absorbable (> 120 days)

Reviews

There are no reviews yet.

Be the first to review “Absorbable Monofilament Polydioxanone PDO/PDS Prime Suture · ½ Circle Cylindrical Body Needle Blunt Point 45 mm (HRN45) · USP Gauge 1 · Violet Thread 90 cm · Ref. AMP413HRN4501 · Box of 12 units”

Your email address will not be published. Required fields are marked *