Description
1. Commercial Introduction
The absorbable monofilament polydioxanone (PDO/PDS) suture, reference AM418HS4002, is the reference solution for professionals who need a long-lasting thread with high initial strength and fully predictable behaviour in the operating theatre. Its ½ circular needle with reverse cutting triangular point, 40 mm (HS 40), offers firm, controlled penetration even in dense tissues, while the 70 cm violet thread ensures optimal visibility and excellent handling with every stitch.
It is a synthetic absorbable medical device, sterile and single-use, with a very competitive price-quality ratio for B2B procurement by hospitals, ophthalmology clinics, private operating theatres and purchasing centres. Supplied in a box of 12 units.
2. Technical explanation of the product and procedure
Polydioxanone is a synthetic polymer composed of poly(p-dioxanone) with a monofilament structure. This single-filament configuration offers extremely smooth, regular passage through tissue, with no sawing effect or capillarity, minimising microorganism drag and tissue reaction, as well as providing firm, secure knot tying even in larger gauges such as USP 2.
Absorption occurs by hydrolysis, i.e. controlled degradation of the polymer in contact with organic fluids, over a predictable period of 180 to 210 days. This prolonged absorption profile makes it suitable for tissues requiring wound support for several months: abdominal wall, intestinal anastomoses, ligament and tendon repair, and paediatric cardiovascular surgery. The ½ circle needle with triangular body and point, reverse cutting, 40 mm, penetrates firm, dense tissue with controlled trauma, being especially suitable for tissue approximation, ligatures, general surgery and ophthalmology.
3. Technical Specifications
3.1. General characteristics of reference AM418HS4002
| Reference (SKU) | AM418HS4002 |
| Material | Polydioxanone (PDO), synthetic absorbable polymer of poly(p-dioxanone) |
| Thread structure | Monofilament |
| Gauge | USP 2 (metric 5) |
| Thread colour | Violet |
| Thread length | 70 cm |
| Needle shape | ½ circle |
| Tip type | Triangular reverse cutting (body and point, Reverse Cutting) |
| Needle size | HS 40 mm |
| Absorption mechanism | Hydrolysis (180-210 days) |
| Sterilisation | Ethylene oxide (single-use, not re-sterilisable) |
| Tissue reaction | Minimal |
| Indications | Tissue approximation, ligatures, general surgery, paediatric cardiovascular surgery and ophthalmology |
| Presentation | Box of 12 units |
3.2. Tensile strength retention profile
| Time after implantation | Retained tensile strength |
| 2 weeks | 75 % |
| 4 weeks | 60-70 % |
| 8 weeks | 45 % |
| Complete absorption | 180-210 days, by hydrolysis |
Minimal tissue reaction, excellent tensile strength and optimal knot tying, with a fully predictable absorption rate. Sterilised by ethylene oxide. Price per box of 12 units.
4. Equivalences and Cross-References
Monofilament polydioxanone is the most widely used long-lasting absorbable suture family on the international market. This reference is clinically positioned in the same category as the following equivalent monofilament polydioxanone line verified in public sources:
| Manufacturer / Brand | Family / Model | Code / SKU | Equivalence level | Technical differences / Remarks |
| Ethicon (Johnson & Johnson MedTech) | PDS II (polydioxanone) monofilament | Z195T | Comparable by category (not interchangeable 1:1) | Same polymer (PDO), USP 2 gauge, ½ circle reverse cutting needle CP 40 mm, violet thread 70 cm. The presentation differs (box of 24 units) and the absorption declared by the manufacturer (182-238 days). Verified in authorised distributor catalogues; confirm availability and EMEA nomenclature with the manufacturer. |
Other equivalent monofilament polydioxanone ranges on the market (B. Braun MonoPlus, Teleflex Monodek, SMI) require individual verification of gauge, needle geometry and thread length in their official datasheet before any substitution, so they are not listed without a verified code. There is no equivalence table validated by the manufacturer; consult the technical department before use in tenders.
5. Selection tips and variants of interest
Choose this suture when the tissue requires prolonged wound support (absorption 6-7 months): abdominal wall, intestinal anastomoses, ligament and tendon repair and paediatric cardiovascular surgery. USP 2 gauge (metric 5) is indicated for tissues requiring high initial strength: deep planes, fascia, aponeurosis and high-tension closures. The reverse cutting triangular point is suitable for penetrating firm, dense tissue without tearing it; for soft, friable tissue consider the conical point variants. If healing is shorter (2-4 weeks), consider the PGA or PGLA families from the same catalogue.
| Reference | Variant |
| AM418HS4002 | PDO USP 2, HS 40 mm needle, violet, 70 cm (current product) |
| AMP418HS4002 | PDO Prime quality, same configuration USP 2, HS 40 mm, violet, 70 cm |
| AM413HS4001 | PDO USP 1, HS 40 mm needle, violet, 90 cm (smaller gauge, more thread) |
| AM413HS4801 | PDO USP 1, HS 48 mm needle, violet, 90 cm (larger radius needle) |
| AM413HR4002 | PDO USP 2, HR 40 mm needle, conical point, violet, 90 cm (delicate tissues) |
| AM113HS4002 | PGA Prime USP 2, HS 40 mm needle, violet, 90 cm (short healing) |
All references are supplied in boxes of 12 units. As this is a sterile single-use product, check the integrity of the packaging before each procedure, respect the expiry date and store the suture in a cool, dry place, protected from sunlight. For special B2B conditions by volume, hospital supply contracts or equivalents from other commercial houses, contact our technical-commercial team.





Reviews