We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice
Sale!

Absorbable Monofilament Polydioxanone (PDO/PDS) Suture | 1/2 Circle Reverse Cutting Triangular Point Needle HS36 (36 mm) | USP 0 Gauge (Metric 3.5) | Violet Thread 75 cm | Ref. 412HS3610 | Box of 12 units

Original price was: 44,90 €.Current price is: 35,50 €.

Absorbable monofilament polydioxanone (PDO/PDS) suture with ½ circle reverse cutting triangular point needle of 36 mm (HS36), USP 0 gauge (metric 3.5) and 75 cm violet fluted thread. Predictable absorption by hydrolysis in 180-210 days, with tensile strength retention of 75 % at 2 weeks, 60-70 % at 4 weeks and 45 % at 8 weeks. Sterile by ethylene oxide, single-use and minimal tissue reaction; indicated for approximation of tissues, ligatures, fascia closure, general surgery, paediatric cardiovascular tissues and ophthalmology. Reference 412HS3610, presentation in a box of 12 units with B2B conditions for hospitals and purchasing centres.

International shipping. Import duties and taxes are payable by the recipient.

Reference
AM412HS3610

Description

1. Product Presentation

The absorbable monofilament polydioxanone (PDO/PDS) suture is the reference technical solution when prolonged tissue support is required with fully predictable resorption and minimal tissue reaction. This presentation combines a 75 cm violet fluted thread with a ½ circle needle, reverse cutting triangular point of 36 mm (HS36), designed to penetrate firm tissues such as fascia with the least possible trauma.

Available in a box of 12 units, it is a cost-effective and reliable option for general surgery departments, paediatric cardiovascular surgery operating theatres, ophthalmology units and hospital purchasing centres seeking consistent quality with CE marking.

2. Technical explanation of the product and procedure

Polydioxanone is a synthetic absorbable polyester that degrades by hydrolysis, a mechanism independent of the patient’s enzymatic activity that ensures highly reproducible absorption kinetics between individuals. Being a monofilament, the thread has no wicking effect or capillary edges, which reduces bacterial adherence and facilitates sliding through tissue; its firm feel and excellent knotting capacity make it suitable for ligatures and sutures of planes under tension.

The ½ circle needle (half-circumference curvature) with reverse cutting triangular point penetrates tissue with a cutting edge that prevents tearing in fibrous walls, and its triangular body provides maximum stability in the needle holder. The USP 0 gauge (metric 3.5) is very versatile: suitable for subcutaneous tissue, superficial muscle planes, approximation of soft tissues, fascia closure and ligatures. The violet colour improves thread visibility on the surgical field. It is supplied sterile by ethylene oxide, single-use and cannot be re-sterilised.

3. Technical Specifications

3.1. General characteristics

Characteristic Specification
Material Polydioxanone (PDO/PDS), absorbable synthetic monofilament polymer
Thread structure Grooved monofilament
Gauge USP 0 (metric 3.5; approximate diameter 0.35-0.399 mm according to Pharmacopoeia)
Thread colour Violet
Thread length 75 cm
Needle shape ½ circle (half circumference)
Tip type Reverse cutting triangular (reverse cutting)
Needle size HS 36 mm
Absorption mechanism Hydrolysis, 180-210 days (complete absorption)
Sterilisation Ethylene oxide (single-use, not re-sterilisable)
Tissue reaction Minimal, with excellent tensile strength and knot tying
Indications Tissue approximation, ligatures, general surgery, fascia, paediatric cardiovascular tissues and ophthalmology
Presentation Box of 12 units
Reference (SKU) 412HS3610 (AM412HS3610)

3.2. Tensile strength retention profile

Time Tensile strength retention
2 weeks 75 %
4 weeks 60-70 %
8 weeks 45 %
Complete absorption 180-210 days by hydrolysis

The force retention profile is maintained during the critical healing phase of slow-healing tissues, which recommends its use in closures of fascia, aponeurosis and structures under sustained tension.

4. Equivalences and Cross-References

Monofilament polydioxanone is the material basis of the market reference lines for long-lasting absorbable sutures. Based on the verified configuration of this data sheet (½ circle reverse cutting triangular needle of 36 mm, USP 0 gauge, 75 cm violet thread), the following commercial reference from another manufacturer has been cross-checked in primary sources:

Manufacturer / Brand Family / Model Code / SKU Equivalence Level Technical Differences / Remarks
Ethicon (Johnson & Johnson MedTech) PDS II, CP-1 needle Z467H Comparable by category (not interchangeable 1:1) Same violet PDO monofilament material, same USP 0 gauge, same ½ circle curvature and reverse cutting point family (CP-1) of 36 mm; thread of 27″ (70 cm) versus 75 cm. Confirmed in Ethicon’s code search engine and in authorised distributors.

As homologous market families to be verified code by code before substitution: Ethicon’s PDS Plus line (same PDO base with antibacterial triclosan coating), the MonoPlus line from B. Braun/Aesculap and the Surgicryl PDO line from SMI, which must be checked in their official technical data sheet (gauge, geometry and needle length). There is no equivalence table validated by the manufacturer; consult the technical department before use in tenders.

5. Selection tips and variants of interest

When choosing a PDO suture, always check the USP gauge according to the tissue plane: fine gauges (4/0 to 6/0) for skin and subcutaneous tissue, 3/0 and 2/0 for general soft tissue, and USP 0 and above for fascia and planes under tension. The needle shape is also decisive: the ½ circle reverse cutting triangular (HS) is designed for fibrous and somewhat firm tissues, while the conical point (HR) is reserved for delicate tissues such as vessels.

This reference (HS36, USP 0, 75 cm) is a medium configuration of the ½ circle triangular family; within the Cahnos catalogue, the following variants of the same PDO family are also available:

Reference Variant of interest
AMP412HS3610 PDO Prime, same HS36 configuration, USP 0, violet, 75 cm (premium range, minimum order 30 boxes)
AM412HS3601 PDO USP 1, same HS36 needle, violet, 75 cm (larger gauge for planes under tension)
AM412HS3620 PDO USP 2/0, same HS36 needle, violet, 75 cm (finer gauge for moderate tension)

As this is sterile single-use material, check the integrity of the packaging before each procedure and store it in a cool, dry place, protected from sunlight. For special B2B conditions, volume orders or other gauges, lengths and colours made to order, contact the technical-commercial team at Cahnos.

Additional information

Material

Polydioxanone (PDO/PDS), absorbable synthetic monofilament polymer

Thread structure

Grooved monofilament

Gauge

USP 0 (metric 3.5)

Thread diameter

0.35 – 0.399 mm (indicative according to Pharmacopoeia)

Needle shape

1/2 circle (half circumference)

Tip type

Reverse cutting triangular (reverse cutting)

Absorption mechanism

Hydrolysis, 180-210 days

Strength retention

75 % (2 weeks), 60-70 % (4 weeks), 45 % (8 weeks)

Sterilisation

Ethylene oxide (single-use, not re-sterilisable)

Tissue reaction

Minimal

Indications

Tissue approximation, ligatures, general surgery, fascia, paediatric cardiovascular tissues and ophthalmology

Presentation

Box of 12 units

Manufacturer reference

412HS3610

Medida de aguja

HS 36

Usp

0

Color

Violet

Medida de hilo

75 cm

Tipo de aguja

Reverse cutting

Forma de aguja

1/2 circle

Calidad sutura

Normal

Reviews

There are no reviews yet.

Be the first to review “Absorbable Monofilament Polydioxanone (PDO/PDS) Suture | 1/2 Circle Reverse Cutting Triangular Point Needle HS36 (36 mm) | USP 0 Gauge (Metric 3.5) | Violet Thread 75 cm | Ref. 412HS3610 | Box of 12 units”

Your email address will not be published. Required fields are marked *