Description
1. Product Presentation
The absorbable monofilament polydioxanone (PDO/PDS) suture is the reference technical solution when prolonged tissue support is required with fully predictable resorption and minimal tissue reaction. This presentation combines a 75 cm violet fluted thread with a ½ circle needle, reverse cutting triangular point of 36 mm (HS36), designed to penetrate firm tissues such as fascia with the least possible trauma.
Available in a box of 12 units, it is a cost-effective and reliable option for general surgery departments, paediatric cardiovascular surgery operating theatres, ophthalmology units and hospital purchasing centres seeking consistent quality with CE marking.
2. Technical explanation of the product and procedure
Polydioxanone is a synthetic absorbable polyester that degrades by hydrolysis, a mechanism independent of the patient’s enzymatic activity that ensures highly reproducible absorption kinetics between individuals. Being a monofilament, the thread has no wicking effect or capillary edges, which reduces bacterial adherence and facilitates sliding through tissue; its firm feel and excellent knotting capacity make it suitable for ligatures and sutures of planes under tension.
The ½ circle needle (half-circumference curvature) with reverse cutting triangular point penetrates tissue with a cutting edge that prevents tearing in fibrous walls, and its triangular body provides maximum stability in the needle holder. The USP 0 gauge (metric 3.5) is very versatile: suitable for subcutaneous tissue, superficial muscle planes, approximation of soft tissues, fascia closure and ligatures. The violet colour improves thread visibility on the surgical field. It is supplied sterile by ethylene oxide, single-use and cannot be re-sterilised.
3. Technical Specifications
3.1. General characteristics
| Characteristic | Specification |
|---|---|
| Material | Polydioxanone (PDO/PDS), absorbable synthetic monofilament polymer |
| Thread structure | Grooved monofilament |
| Gauge | USP 0 (metric 3.5; approximate diameter 0.35-0.399 mm according to Pharmacopoeia) |
| Thread colour | Violet |
| Thread length | 75 cm |
| Needle shape | ½ circle (half circumference) |
| Tip type | Reverse cutting triangular (reverse cutting) |
| Needle size | HS 36 mm |
| Absorption mechanism | Hydrolysis, 180-210 days (complete absorption) |
| Sterilisation | Ethylene oxide (single-use, not re-sterilisable) |
| Tissue reaction | Minimal, with excellent tensile strength and knot tying |
| Indications | Tissue approximation, ligatures, general surgery, fascia, paediatric cardiovascular tissues and ophthalmology |
| Presentation | Box of 12 units |
| Reference (SKU) | 412HS3610 (AM412HS3610) |
3.2. Tensile strength retention profile
| Time | Tensile strength retention |
|---|---|
| 2 weeks | 75 % |
| 4 weeks | 60-70 % |
| 8 weeks | 45 % |
| Complete absorption | 180-210 days by hydrolysis |
The force retention profile is maintained during the critical healing phase of slow-healing tissues, which recommends its use in closures of fascia, aponeurosis and structures under sustained tension.
4. Equivalences and Cross-References
Monofilament polydioxanone is the material basis of the market reference lines for long-lasting absorbable sutures. Based on the verified configuration of this data sheet (½ circle reverse cutting triangular needle of 36 mm, USP 0 gauge, 75 cm violet thread), the following commercial reference from another manufacturer has been cross-checked in primary sources:
| Manufacturer / Brand | Family / Model | Code / SKU | Equivalence Level | Technical Differences / Remarks |
|---|---|---|---|---|
| Ethicon (Johnson & Johnson MedTech) | PDS II, CP-1 needle | Z467H | Comparable by category (not interchangeable 1:1) | Same violet PDO monofilament material, same USP 0 gauge, same ½ circle curvature and reverse cutting point family (CP-1) of 36 mm; thread of 27″ (70 cm) versus 75 cm. Confirmed in Ethicon’s code search engine and in authorised distributors. |
As homologous market families to be verified code by code before substitution: Ethicon’s PDS Plus line (same PDO base with antibacterial triclosan coating), the MonoPlus line from B. Braun/Aesculap and the Surgicryl PDO line from SMI, which must be checked in their official technical data sheet (gauge, geometry and needle length). There is no equivalence table validated by the manufacturer; consult the technical department before use in tenders.
5. Selection tips and variants of interest
When choosing a PDO suture, always check the USP gauge according to the tissue plane: fine gauges (4/0 to 6/0) for skin and subcutaneous tissue, 3/0 and 2/0 for general soft tissue, and USP 0 and above for fascia and planes under tension. The needle shape is also decisive: the ½ circle reverse cutting triangular (HS) is designed for fibrous and somewhat firm tissues, while the conical point (HR) is reserved for delicate tissues such as vessels.
This reference (HS36, USP 0, 75 cm) is a medium configuration of the ½ circle triangular family; within the Cahnos catalogue, the following variants of the same PDO family are also available:
| Reference | Variant of interest |
|---|---|
| AMP412HS3610 | PDO Prime, same HS36 configuration, USP 0, violet, 75 cm (premium range, minimum order 30 boxes) |
| AM412HS3601 | PDO USP 1, same HS36 needle, violet, 75 cm (larger gauge for planes under tension) |
| AM412HS3620 | PDO USP 2/0, same HS36 needle, violet, 75 cm (finer gauge for moderate tension) |
As this is sterile single-use material, check the integrity of the packaging before each procedure and store it in a cool, dry place, protected from sunlight. For special B2B conditions, volume orders or other gauges, lengths and colours made to order, contact the technical-commercial team at Cahnos.