We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice

Paediatric SpO2 Replacement Catheter for SPIROLAB 33520 Spirometer – Original Replacement | Ref. 33696

470,25 €

Original replacement paediatric pulse oximetry (SpO2) catheter (ref. 33696), spare part for the saturation module of the SPIROLAB spirometer ref. 33520. Designed for paediatric patients, it allows you to replace or replenish the standard sensor and maintain reliable, non-invasive monitoring of oxygen saturation during spirometry. Original manufacturer replacement that guarantees compatibility and precision in pulmonology services, primary care, occupational medicine and pulmonary function laboratories. For large orders you can request a quote.consult our technical-commercial team for B2B conditions and availability.

Sales unit: 1 unidad
Minimum order for products shipped from Italy: 150,00 € excluding VAT (can be combined)

Delivery time: 15 days

International shipping. Import duties and taxes are payable by the recipient.

Reference
GM33696

Description

1. Introduction

The paediatric SpO2 catheter ref. 33696 is the original replacement designed for the pulse oximetry module of the SPIROLAB spirometer ref. 33520 from the same manufacturer. It is a spare part that allows you to keep the oxygen saturation measurement operational without having to purchase new equipment: when the standard sensor deteriorates from continued use or you wish to have an additional catheter to alternate between patients, this paediatric catheter restores the full functionality of your spirometer. A European reference in medical and diagnostic equipment, it is the ideal solution for pulmonology services, primary care, occupational medicine and pulmonary function laboratories.

2. Technical explanation

Pulse oximetry (SpO2) is a non-invasive optical technique that estimates the functional oxygen saturation of arterial haemoglobin through the differential absorption of red and infrared light across the patient’s capillary bed. The catheter integrates the emitter and photodetector in a compact element, adapted to the paediatric patient’s anatomy, which is placed on the finger and transmits the signal to the device; the spirometer processes that signal and displays the saturation value (SpO2) and pulse rate on screen during the examination. As it is an external replacement, its correct placement and condition are crucial for obtaining stable and repeatable readings, both in spot tests and in short-term monitoring.

3. Technical Specifications

Original replacement paediatric pulse oximetry (SpO2) catheter for the SPIROLAB spirometer ref. 33520 configured with a saturation module.

Product data

Manufacturer GIMA
Manufacturer reference 33696
Sales unit 1 pc
Device type Medical device
Device class II B
CND C900301
EAN 8023279336962

Features and compatibility

Parameter Specification
Sensor type Paediatric SpO2 replacement catheter (spare)
Patient population Paediatric
Compatible equipment Spirometer SPIROLAB ref. 33520 (pulse oximetry module)
Use Replacement / spare for the original sensor

4. Equivalences and Cross-References

Reference 33696 is the original code for this paediatric SpO2 replacement catheter intended for the SPIROLAB 33520 spirometer. Within the catalogue itself, equivalent paediatric pulse oximetry catheters are documented for other equipment lines: the paediatric catheter 34347 and the reusable paediatric catheter 33731 (family of pulse oximeters 34341 / OXY-110), as well as the paediatric catheters 35096, 35097 and 35136 for other equipment from the manufacturer. No official equivalence table has been found in reliable sources that cross-references this reference with SpO2 sensors from third-party manufacturers (Nonin, Masimo, Nellcor, etc.), since compatibility depends on the connector and the measurement protocol of each device; before considering any replacement with an alternative brand catheter, confirm compatibility with our technical-commercial department.

5. Selection tips and variants of interest

Verify that your device corresponds to the SPIROLAB spirometer ref. 33520 and that it has the pulse oximetry module before placing the order: this catheter is the replacement intended for that module and its connector is specific. As it is a reusable sensor, follow the manufacturer’s cleaning and maintenance instructions between patients and periodically check the cable and the contact area to avoid erroneous readings. It is recommended to have at least one spare unit per active device to minimise downtime in the service. To complete the equipment of your spirometer, in the same family you have the miniflowmeter with cable (ref. 33697) and the reusable bayonet-type turbine (ref. 33526), as well as other SpO2 catheters in adult and neonatal versions for different devices in the catalogue. For large orders you can request a quote: contact the technical-commercial team of Cahnos for B2B conditions, availability and compatibility advice.

Additional information

Manufacturer reference

33696

Product type

Paediatric SpO2 replacement catheter

CND code

C900301

EAN

8023279336962

Compatibility

Spirometer SPIROLAB ref. 33520 (pulse oximetry module)

Use

Replacement / spare for the original sensor

Presentacion

Unit

Tipo dispositivo

Medical device

Clase sanitaria

II b

Tipo paciente

Paediatric

Documentation

📄 DatasheetEnglish PDF
📜 Declaration of conformityEnglish PDF
📜 CE certificateDownload PDF
📜 ISO 9001 / 13485 certificatesMultilingüe PDF

Reviews

There are no reviews yet.

Be the first to review “Paediatric SpO2 Replacement Catheter for SPIROLAB 33520 Spirometer – Original Replacement | Ref. 33696”