We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice

ECG thermal paper block GE / Hellige / Marquette · CASE 12/15/16, MAC 6/8/12/15, MAC 5000/5500/3500/8000, CASE V6-01/V5-05 · 214×280 mm × 300 sheets · Red grid · OEM 9402-020 / 2009828-020 · Ref. 0553130

55,00 €

ECG thermal paper block of 214×280 mm with 300 sheets and red grid, compatible with GE / Hellige / Marquette electrocardiographs CASE 12/15/16, MAC 6/8/12/15, MAC 3500, MAC 5000, MAC 5500, MAC 8000, CASE V6-01 and CASE V5-05. Reproduces the construction of the original equipment reference 9402-020 (2009828-020): direct thermal printing by head, without ink or toner, with sharp, stable trace suitable for clinical archiving (approximate readability of 5 years under suitable conditions). Presentation in a box of 5 blocks with delivery in 24/72 h. Reference Cahnos 0553130 (factory code 12426).

International shipping. Import duties and taxes are payable by the recipient.

Reference
0553130

Description

1. Commercial Introduction

The ECG thermal paper block reference 0553130 is the recording consumable that keeps the electrocardiographs of the GE / Hellige / Marquette family operational: CASE 12/15/16, MAC 6/8/12/15, MAC 3500, MAC 5000, MAC 5500, MAC 8000, CASE V6-01 and CASE V5-05. Its 214×280 mm format with 300 sheets and red grid is designed for resting and stress electrocardiographic recording in cardiology departments, ECG clinics, intensive care units and stress testing laboratories.

It reproduces the construction of the original equipment reference 9402-020 (also documented as 2009828-020 in distribution), which guarantees reliable paper behaviour in the recorder. The presentation in a box of 5 blocks allows planned and cost-effective replenishment. Available with delivery in 24/72 h; request a formal quotation for institutional orders and tenders.

2. Technical Explanation

The GE / Marquette / Hellige electrocardiographs of these series record on thermal paper: the image is generated by contact of the thermal print head on the thermosensitive layer of the paper, without the need for ink, toner or ribbon. The pre-printed red grid acts as a measurement reference (amplitude, recording speed and segments) and is essential for the correct interpretation of the ECG and stress tests.

The Z-fold block format (fanfold / z-fold) facilitates continuous sheet feeding, prevents jams in the recorder and allows subsequent archiving of the trace in the clinical record. The grammage and thermal sensitivity are adjusted to the head of these devices to guarantee sharp, stable and durable traces (trace legibility of approximately 5 years under adequate archiving conditions, with declarations of up to 12 years depending on the paper manufacturer), preserving the integrity of the clinical document.

3. Technical Specifications

Characteristic Specification
Reference Cahnos (SKU) 0553130
Equipment reference (OEM) GE-Marquette 9402-020 · 2009828-020
Paper factory reference 12426 (internal line code; do not use as equipment manufacturer reference)
Block dimensions 214 mm (width) × 280 mm (length) × 300 sheets (also commercially quoted as 215 mm wide according to paper manufacturer)
Format Z-fold block (fanfold / z-fold)
Grid colour Red
Paper type High-sensitivity heat-sensitive paper for thermal printhead
Print technology Direct thermal printhead (no ink, toner or ribbon)
Application Electrocardiographic recording (resting and stress ECG) on GE / Hellige / Marquette equipment
Declared compatibility CASE 12/15/16 · MAC 6/8/12/15 · MAC 3500 · MAC 5000 · MAC 5500 · MAC 8000 · CASE V6-01 · CASE V5-05
Commercial presentation Box of 5 blocks
Trace shelf life Approx. 5 years after printing (adequate archiving conditions); up to 12 years according to paper manufacturer’s declaration
Storage 5 °C – 40 °C, cool and dry place; avoid direct sunlight and excessive humidity
Classification Class I medical device (with measuring function) · CE · R.D. 1591/2009 · European Directives 93/42/EEC and 2007/47/EC

4. Equivalences and Cross-References

Reference 9402-020 is consistently confirmed in multiple authorised distributors as the original code for this construction (214–215×280 mm × 300 sheets, red grid, Z-fold) for the CASE / MAC families of GE-Marquette. Code 2009828-020 (Vyaire Medical) is consistently verified in distribution catalogues for the same dimension and grid, although its presence in public regulatory databases (GUDID/FDA) could not be independently confirmed. There is no official equivalence table published by GE HealthCare authorising third-party consumables; the following references are offered as verified comparisons and must be confirmed with the technical department before use in tenders.

Manufacturer / Brand Family / Model Reference code / SKU Equivalence level Technical differences / Remarks
GE HealthCare (original equipment) ECG thermal recording paper 215×280 mm × 300 sheets, red grid, Z-fold for CASE / MAC 9402-020 Comparable by category (not interchangeable 1:1) Original equipment reference reproduced by this block, consistently confirmed in multiple authorised European and American distributors for the same dimensions 214–215×280×300 with red grid. Verify header, grammage and number of sheets of the batch before replacing.
Vyaire Medical (distribution) ECG recording paper 215×280 mm × 300 sheets, red grid, Z-fold 2009828-020 Comparable by category (not interchangeable 1:1) Same construction and dimensions as reference 9402-020, consistently confirmed in authorised European distributors; not located in GUDID/FDA (pending independent confirmation). Verify presentation and grid colour of the batch before replacing.

There is no equivalence table validated by the equipment manufacturer (GE HealthCare) authorising third-party consumables for reference 9402-020; consult the technical department before use in tenders. Always verify the sheet width (214–215 mm), the grid colour (red), the grammage and the number of sheets per block of the received batch before formalising the replacement. Code 12426 accompanying the reference is an internal factory line code and must not be used as a manufacturer code: the reference identifying the consumable is OEM 9402-020.

5. Selection tips and variants of interest

Verify the exact model of the equipment: this block of 214×280 mm × 300 sheets is the one intended for the large-format CASE / MAC families (OEM 9402-020). Do not confuse it with the block of 210×280 mm corresponding to reference 9402-021 (Cahnos entry 0553162), nor with the block of 215×280 mm of reference 9402-024 (ref. 0992810): they share the same equipment family but differ in sheet width and grid construction; they are not interchangeable without prior verification.

Z-fold format: confirm that your recorder compartment accepts fanfold block; most MAC / CASE series require it, but some older systems use other dimensions. If your equipment prints on 108 mm continuous roll, select reference 0553175-EH (OEM 9402-023) from our family. For the MAC 800, use the 110×140 mm block (ref. 0553057); for Microsmart / MAC 500, the 90×90×360 sheets block (ref. 0553064).

Presentation: this reference is supplied in a box of 5 blocks; in the US market the same format is usually sold in boxes with a larger number of packs. Always compare the price per sheet and the number of blocks per box.

Storage: store the blocks in a cool, dry place (5 °C – 40 °C), protected from direct sunlight and heat sources, to preserve the thermosensitive layer and prevent trace fogging. For institutional orders or tenders, contact our technical-commercial department to confirm compatibility and supply conditions.

Additional information

Manufacturer reference

12426 (internal line code; do not use as manufacturer reference)

Measurements

214 × 280 mm (also commercially quoted as 215 mm wide)

Number of sheets

300 sheets per block

Format

Z-fold block (fanfold / z-fold)

Grid colour

Red

Paper type

High-sensitivity thermal paper for thermal print head

Print technology

Direct thermal printhead (no ink, toner or ribbon)

Compatibility

GE / Hellige / Marquette: CASE 12/15/16, MAC 6/8/12/15, MAC 3500, MAC 5000, MAC 5500, MAC 8000, CASE V6-01, CASE V5-05

Presentation

Box of 5 blocks

Shelf life

Approx. 5 years after printing (up to 12 years depending on paper manufacturer)

Storage

5 °C – 40 °C, cool and dry place; avoid direct sunlight and excessive humidity

Regulatory classification

Medical device Class I (with measuring function) · CE · R.D. 1591/2009 · Directives 93/42/EEC and 2007/47/EC

Reviews

There are no reviews yet.

Be the first to review “ECG thermal paper block GE / Hellige / Marquette · CASE 12/15/16, MAC 6/8/12/15, MAC 5000/5500/3500/8000, CASE V6-01/V5-05 · 214×280 mm × 300 sheets · Red grid · OEM 9402-020 / 2009828-020 · Ref. 0553130”

Your email address will not be published. Required fields are marked *