Description
1. Commercial Introduction
The ECG thermal paper block reference 0553130 is the recording consumable that keeps the electrocardiographs of the GE / Hellige / Marquette family operational: CASE 12/15/16, MAC 6/8/12/15, MAC 3500, MAC 5000, MAC 5500, MAC 8000, CASE V6-01 and CASE V5-05. Its 214×280 mm format with 300 sheets and red grid is designed for resting and stress electrocardiographic recording in cardiology departments, ECG clinics, intensive care units and stress testing laboratories.
It reproduces the construction of the original equipment reference 9402-020 (also documented as 2009828-020 in distribution), which guarantees reliable paper behaviour in the recorder. The presentation in a box of 5 blocks allows planned and cost-effective replenishment. Available with delivery in 24/72 h; request a formal quotation for institutional orders and tenders.
2. Technical Explanation
The GE / Marquette / Hellige electrocardiographs of these series record on thermal paper: the image is generated by contact of the thermal print head on the thermosensitive layer of the paper, without the need for ink, toner or ribbon. The pre-printed red grid acts as a measurement reference (amplitude, recording speed and segments) and is essential for the correct interpretation of the ECG and stress tests.
The Z-fold block format (fanfold / z-fold) facilitates continuous sheet feeding, prevents jams in the recorder and allows subsequent archiving of the trace in the clinical record. The grammage and thermal sensitivity are adjusted to the head of these devices to guarantee sharp, stable and durable traces (trace legibility of approximately 5 years under adequate archiving conditions, with declarations of up to 12 years depending on the paper manufacturer), preserving the integrity of the clinical document.
3. Technical Specifications
| Characteristic | Specification |
| Reference Cahnos (SKU) | 0553130 |
| Equipment reference (OEM) | GE-Marquette 9402-020 · 2009828-020 |
| Paper factory reference | 12426 (internal line code; do not use as equipment manufacturer reference) |
| Block dimensions | 214 mm (width) × 280 mm (length) × 300 sheets (also commercially quoted as 215 mm wide according to paper manufacturer) |
| Format | Z-fold block (fanfold / z-fold) |
| Grid colour | Red |
| Paper type | High-sensitivity heat-sensitive paper for thermal printhead |
| Print technology | Direct thermal printhead (no ink, toner or ribbon) |
| Application | Electrocardiographic recording (resting and stress ECG) on GE / Hellige / Marquette equipment |
| Declared compatibility | CASE 12/15/16 · MAC 6/8/12/15 · MAC 3500 · MAC 5000 · MAC 5500 · MAC 8000 · CASE V6-01 · CASE V5-05 |
| Commercial presentation | Box of 5 blocks |
| Trace shelf life | Approx. 5 years after printing (adequate archiving conditions); up to 12 years according to paper manufacturer’s declaration |
| Storage | 5 °C – 40 °C, cool and dry place; avoid direct sunlight and excessive humidity |
| Classification | Class I medical device (with measuring function) · CE · R.D. 1591/2009 · European Directives 93/42/EEC and 2007/47/EC |
4. Equivalences and Cross-References
Reference 9402-020 is consistently confirmed in multiple authorised distributors as the original code for this construction (214–215×280 mm × 300 sheets, red grid, Z-fold) for the CASE / MAC families of GE-Marquette. Code 2009828-020 (Vyaire Medical) is consistently verified in distribution catalogues for the same dimension and grid, although its presence in public regulatory databases (GUDID/FDA) could not be independently confirmed. There is no official equivalence table published by GE HealthCare authorising third-party consumables; the following references are offered as verified comparisons and must be confirmed with the technical department before use in tenders.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
| GE HealthCare (original equipment) | ECG thermal recording paper 215×280 mm × 300 sheets, red grid, Z-fold for CASE / MAC | 9402-020 | Comparable by category (not interchangeable 1:1) | Original equipment reference reproduced by this block, consistently confirmed in multiple authorised European and American distributors for the same dimensions 214–215×280×300 with red grid. Verify header, grammage and number of sheets of the batch before replacing. |
| Vyaire Medical (distribution) | ECG recording paper 215×280 mm × 300 sheets, red grid, Z-fold | 2009828-020 | Comparable by category (not interchangeable 1:1) | Same construction and dimensions as reference 9402-020, consistently confirmed in authorised European distributors; not located in GUDID/FDA (pending independent confirmation). Verify presentation and grid colour of the batch before replacing. |
There is no equivalence table validated by the equipment manufacturer (GE HealthCare) authorising third-party consumables for reference 9402-020; consult the technical department before use in tenders. Always verify the sheet width (214–215 mm), the grid colour (red), the grammage and the number of sheets per block of the received batch before formalising the replacement. Code 12426 accompanying the reference is an internal factory line code and must not be used as a manufacturer code: the reference identifying the consumable is OEM 9402-020.
5. Selection tips and variants of interest
Verify the exact model of the equipment: this block of 214×280 mm × 300 sheets is the one intended for the large-format CASE / MAC families (OEM 9402-020). Do not confuse it with the block of 210×280 mm corresponding to reference 9402-021 (Cahnos entry 0553162), nor with the block of 215×280 mm of reference 9402-024 (ref. 0992810): they share the same equipment family but differ in sheet width and grid construction; they are not interchangeable without prior verification.
Z-fold format: confirm that your recorder compartment accepts fanfold block; most MAC / CASE series require it, but some older systems use other dimensions. If your equipment prints on 108 mm continuous roll, select reference 0553175-EH (OEM 9402-023) from our family. For the MAC 800, use the 110×140 mm block (ref. 0553057); for Microsmart / MAC 500, the 90×90×360 sheets block (ref. 0553064).
Presentation: this reference is supplied in a box of 5 blocks; in the US market the same format is usually sold in boxes with a larger number of packs. Always compare the price per sheet and the number of blocks per box.
Storage: store the blocks in a cool, dry place (5 °C – 40 °C), protected from direct sunlight and heat sources, to preserve the thermosensitive layer and prevent trace fogging. For institutional orders or tenders, contact our technical-commercial department to confirm compatibility and supply conditions.




Reviews
There are no reviews yet.