Description
1. Product Presentation
The Welch Allyn thermal paper pad (ref. Cahnos 0553012) is the recording consumable that keeps the CP 100 and CP 200 electrocardiographs operational in cardiology clinics, emergency departments, general practice and diagnostic centres. Its sheet format of 210 × 280 mm with 200 sheets per pad and red grid ensures clear, stable and perfectly measurable tracings at every attendance, ensuring continuity of care and correct clinical documentation of the patient.
It is supplied in a box of 10 units, the most cost-effective presentation to avoid service interruptions due to lack of paper, with delivery in 24-72 h and special B2B terms for institutional orders, maintenance contracts and tenders.
2. Technical Explanation
This pad uses direct thermal printing technology: the electrocardiograph’s thermal head transfers heat to the paper’s thermosensitive layer and produces the trace instantly, without the need for ink, toner or ribbon, which reduces equipment maintenance and maintains consistent print quality throughout the entire pad.
The pre-printed red grid acts as a millimetric measurement reference (recording paper with measuring function): it allows assessment of wave amplitude (mV), interval duration (PR, QT, RR) and recording speeds (mm/s), facilitating clinical interpretation of the electrocardiogram. The Z-fold (fanfold) format is placed directly in the equipment tray, prevents jams in the recorder and allows subsequent filing of the recording in the clinical history. As it is medical recording paper with a measuring function, it belongs to the Class I medical devices range; check the CE marking of the batch.
3. Technical Specifications
| Characteristic | Specification |
| Brand / compatible equipment | Welch Allyn — CP 100 and CP 200 electrocardiographs (resting ECG) |
| Model / manufacturer reference | 94016-0000 / CP 100 – CP 200 · 94018-0000 |
| Reference Cahnos (SKU) | 0553012 – 13720 |
| Format | Z-fold paper pad (accordion / fanfold) |
| Sheet dimensions | 210 mm × 280 mm |
| Number of sheets | 200 sheets per pad |
| Grid colour | Red |
| Paper type | High-sensitivity heat-sensitive thermal paper for thermal printhead |
| Print technology | Direct thermal printhead (no ink, toner or ribbon) |
| Commercial presentation | Box of 10 blocks |
| Application | Electrocardiographic (ECG) recording and clinical documentation |
| Regulatory classification | Class I medical device (with measuring function) · R.D. 1591/2009 · Directives 93/42/EEC and 2007/47/EC |
| Trace shelf life | Approx. 5 years after printing under proper storage conditions |
| Storage | 5 °C to 40 °C, cool and dry place, without direct sunlight or excess humidity |
4. Equivalences and Cross-References
There is no equivalence table validated by the equipment manufacturer (Welch Allyn / Hillrom) that authorises third-party consumables for references 94016-0000 / 94018-0000. The following references belong to the same category (Z-fold ECG thermal paper of 210 × 280 mm × 200 sheets, red grid) and have been verified in public catalogues of their own manufacturers or authorised distributors; before substituting in a tender, the number of sheets, grid colour and format must be checked one by one.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
| EasyTrace (Modul USA) | Z-fold ECG paper for Welch Allyn printers (equivalent to original 94018-0000) | WE210280P1 | Comparable by category (not interchangeable 1:1) | Same format 210 × 280 mm × 200 sheets, box of 10; declared equivalent to original 94018-0000 for CP 100 / CP 200 equipment. Confirmed in manufacturer’s catalogue. |
| Quality Chart Paper (USA) | Welch Allyn 94016-0000 for CP 100 / CP 150 / CP 200 | WE210280PA1 | Comparable by category (not interchangeable 1:1) | 210 × 280 mm × 200 sheets, red grid; declared reproduction of original reference 94016-0000. Confirmed in manufacturer’s catalogue. |
| Danlee Medical / Print Media (USA) | Diagnostic Recording Chart Paper for Welch Allyn 94016-0000 (CP 10 / CP 20) | 2234651 | Comparable by category (not interchangeable 1:1) | 210 × 280 mm, red grid, 200 sheets, fan-fold format; independent manufacturer declaring compatibility with reference 94016-0000. Confirmed in manufacturer’s catalogue and authorised distribution. |
There is no equivalence table validated by the manufacturer; consult the technical department before use in a tender. In the American and European market, recording paper brands such as EasyTrace (Modul USA / DEAS), Leonhard Lang USA, Quality Chart Paper and ECG Paper Depot market comparable z-fold paper for this family of equipment; their specific codes must be verified against the manufacturer or the technical department before use. In the Cahnos catalogue, pads 0553178-S (Schiller AT-102), 0553178-EB (Esaote P-8000 Power) and 0553118 (Siemens Burdick) share the 210 × 280 × 200-sheet packaging with red grid, but are assembled for other families of electrocardiographs: they are not interchangeable 1:1 without prior verification.
5. Selection tips and variants of interest
Check the exact model of your equipment: this pad is designed for Welch Allyn CP 100 and CP 200 electrocardiographs with a 210 mm wide thermal head recorder. Do not confuse it with the CP 50 pad (114 × 70 mm × 250 sheets, ref. 0553096, P/N 406021) or with the pad for CP 10 / CP 20 (210 × 280 mm × 200 sheets, ref. 14979), which share the brand but differ in measurements or equipment family. Also do not confuse pad with roll: if your equipment prints on roll, select the corresponding roll reference from our range of recording papers.
Before replenishing, check three details on your electrocardiograph: paper width (210 mm), loading format (Z-fold pad) and grid colour (red). A different format will not fit in the equipment compartment and will cause misaligned recordings; versions of the same physical format with a different grid colour must not be substituted without prior technical validation, as they affect the millimetric reading of the recording.
Store the blocks in a cool, dry place (5 °C – 40 °C), protected from direct sunlight and heat sources, to preserve the sensitivity of the thermal layer, prevent the trace from becoming obscured and ensure the legibility of the record in the clinical file. For hospitals, consortia and continuous supply contracts we can schedule periodic deliveries; request a formal quotation from our technical-commercial team at Cahnos.