Description
1. The recording consumable for your Mortara ELI 50 electrocardiograph
The Mortara Rangoni ECG thermal paper pad (ref. Cahnos 0553013-MR) is the reference recording consumable for the compact electrocardiographs Mortara Rangoni ELI 50 and ELI 50 i. Its sheet format of 50×70 mm, with 260 sheets per pad and a high-contrast red grid, guarantees sharp, stable and perfectly measurable tracings in every consultation, ensuring continuity of care and correct clinical documentation of the patient. This spare part, with permanent stock and delivery in 24-72 h, is designed for cardiology clinics, emergency departments, general practice and centres that cannot afford interruptions in recording due to lack of paper; the box of 20 pads is the most cost-effective presentation to ensure continuous replenishment of the service.
2. Technical explanation: thermal printing and recording with measuring grid
This pad uses direct thermal printing technology: the electrocardiograph’s thermal head transfers heat to the paper’s thermosensitive layer and generates the tracing instantly, without the need for ink, toner or ribbon, which reduces equipment maintenance and maintains consistent print quality throughout the entire pad. The pre-printed red grid acts as a millimetric measurement reference on the paper itself (recording paper with measuring function): it allows the amplitude of the waves (mV), the duration of the intervals (PR, QT, RR) and the recording speeds in mm/s to be assessed, facilitating clinical interpretation of the electrocardiogram and its subsequent filing in the patient’s medical record. The Z-fold (fanfold) format is placed directly in the equipment tray, avoiding jams and speeding up replacement. The paper is formulated with high-sensitivity thermosensitive quality (Quicktrace® HS range), suitable for the grammage required by the printhead system of these devices. For proper operation, the pad must be stored protected from direct sunlight and humidity, at a stable temperature between 5 °C and 40 °C; the durability of the printed tracing is approximately 5 years if stored properly.
3. Technical Specifications
The following specifications correspond to the Mortara Rangoni thermal paper pad reference 0553013-MR, of equivalent construction to the original equipment designation 00305003 (ZTC 50 P):
| Characteristic | Specification |
| Reference Cahnos (SKU) | 0553013-MR |
| Equipment OEM reference | Mortara Rangoni 00305003 (designation ZTC 50 P) |
| Factory / line reference | 29.050.02 (LESSA) · supplier code 7719 |
| Compatible models | Mortara Rangoni ELI 50 and ELI 50 i |
| Sheet dimensions | 50 mm × 70 mm |
| Number of sheets | 260 sheets per pack |
| Grid colour | Red |
| Format | Z-fold pack (fanfold) |
| Paper type | High-sensitivity heat-sensitive thermal paper (Quicktrace® HS range) |
| Print technology | Direct thermal printhead (no ink, toner or ribbon) |
| Commercial presentation | Box of 20 units |
| Application | Medical recording: electrocardiography (ECG), stress tests and tracings with compatible thermal printer |
| Regulatory classification | Medical device Class I (with measuring function) · R.D. 1591/2009 · European Directives 93/42/EEC and 2007/47/EC |
| Trace shelf life | Approx. 5 years after printing under proper storage conditions |
| Storage | Cool, dry place (5 °C – 40 °C), away from direct sunlight and excessive humidity |
Equipment compatibility (same pad footprint 50×70 mm):
| Brand / equipment family | Models | Observations |
| Mortara Rangoni | ELI 50 / ELI 50 i | Reference format of this data sheet (OEM 00305003, designation ZTC 50 P). |
| Cardiorapid (common market use) | K 312 D | Same pad footprint 50×70×260 sheets with orange grid; verify the grid colour accepted by the equipment before replacing. |
4. Equivalences and Cross-References
The OEM reference 00305003 (designation ZTC 50 P) corresponds to the original consumable of the Mortara Rangoni ELI 50 / ELI 50 i electrocardiograph itself and is consistently confirmed in the reference catalogue of recording paper LESSA / AB Medica Group (factory ref. 29.050.02) and in recording paper manufacturers with official listings (EasyTrace / DEAS – Modul Diagram). There is no official equivalence table published by Mortara authorising third-party consumables for this reference; the following references belong to the same category (ECG thermal paper pad 50×70 mm for head recorders) and are classified as comparable by category, not interchangeable 1:1, requiring technical validation before use in tenders. The same-footprint variant from the Cahnos catalogue for Cardiorapid K 312 D (ref. 0553013-CR, orange grid) is not listed as an equivalence: it shares dimensions and factory reference 29.050.02 but differs in grid colour and must be validated against the equipment before replacement.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
| LESSA / AB Medica Group (Spain) | Folded paper pack Mortara ELI 50 / ELI 50 i (OEM 00305003, ZTC 50 P), 50×70×260 sheets, red grid | 29.050.02 (in Cahnos: 0992637) | Comparable by category (not interchangeable 1:1) | Same target OEM (00305003), same dimensions 50×70×260 and red grid; different paper packer and commercial presentation. Confirm number of pads per box. |
| EasyTrace / DEAS – Modul Diagram (Italy) | ECG thermal paper M. Rangoni 00305003 ELI 50 / Cardiorapid K312, 50×70 mm | ES-BR5070P | Comparable by category (not interchangeable 1:1) | Same dimensions 50×70 mm; 200 sheets per pad versus the 260 of this reference. Confirmed in official brand listings (CE marking, made in Italy). |
There is no equivalence table validated by the manufacturer; consult the technical department before use in tenders. Alternative packagings with the same OEM 00305003 supplied by distributors are also available on the market (e.g. Quality Chart Paper 50×70×200 sheets and the distribution code TPC-37642 from Zenithmed/MediGrid for the 5×200 presentation), distributor codes that must be verified against the equipment manufacturer before substitution. Double-check note: in the internal master catalogue, code 0553013 appears associated in some of its editions with an orange grid (Cardiorapid K 312 D variant, ref. 0553013-CR); this supply (ref. 0553013-MR) is supplied with a red grid. Confirm the batch colour with the technical department before use in tender documents.
5. Selection tips and variants of interest
Verify the exact model of your equipment: this 50×70 mm pad is the one indicated for the Mortara Rangoni ELI 50 and ELI 50 i electrocardiographs with a 50 mm wide thermal head recorder. Always confirm the grid colour of your protocol (in this supply line it is red; the orange-grid variant of the same footprint is not interchangeable without technical validation). Also check the loading format (Z-fold pad or roll) and the number of sheets in the batch, since the same OEM 00305003 is distributed on the market with 200 or 260 sheets depending on the supply. For intensive use in cardiology departments, the box of 20 pads ensures continuity of supply. Variants of the same Mortara family in the Cahnos catalogue: roll for ELI 100 of 108 mm × 23 m (ref. 0553175-MR, OEM 9100-016-50), 215×280 mm pad for ELI 250 i / ELI 350 (ref. 0553200), Z-fold pad for ELI 210/250/350 (ref. 0992016) and roll for ELI 230 (ref. 0553499); do not substitute one format for another without prior technical validation. Store the paper in a cool, dry place (5-40 °C), protected from direct sunlight and heat sources, to preserve the stability of the trace and avoid fogging of the thermal layer. For institutional orders, tenders or continuous supply contracts, contact our technical-commercial department to confirm compatibility, exact reference and formalised quotation.



Reviews
There are no reviews yet.