Description
1. Product Presentation
The Ophthalmic Blade with Sharp Point, Angled 45°, 19 Gauge (Double Bevel) with 2.8 mm blade is a precision keratome designed for surgeons who demand maximum control in anterior segment ocular microsurgery. Made of high-quality surgical steel, this micro-instrument ensures clean, controlled and self-sealing incisions, optimising surgical outcomes and reducing the risk of postoperative complications. It is the reliable choice for hospitals, ophthalmic clinics and surgical centres that value repeatability and safety at every step of the procedure.
2. Technical explanation
Angled sharp-pointed blades or keratomes are mainly used to create the clear corneal entry incision in cataract phacoemulsification surgery, as well as to prepare and widen the incision for intraocular lens (IOL) implantation. The 45° angulation separates the handle from the cutting area, facilitating the correct angle of attack on the cornea and allowing the blade to be maintained in a stable plane during the incision. The sharp point favours controlled initial penetration, while the double bevel sharpening (on both sides) produces a symmetrical and uniform cut, with less resistance to advancement and sharp incision edges. The result is a self-sealing wound with minimal tissue distortion and less induced astigmatism, which favours anterior chamber stability, reduces postoperative leakage and speeds up patient recovery. As a single-use instrument, the risk of cross-contamination is eliminated and an intact edge is guaranteed in every procedure.
3. Technical Specifications
The main technical specifications of the product are detailed below:
| Characteristic | Specification |
| Type | Ophthalmic blade (keratome) with sharp point angled 45° |
| Blade width | 2.8 mm |
| Tip | Sharp |
| Bevel | Double bevel (sharpened on both sides) |
| Gauge | 19 |
| Angulation | 45° |
| Material | High-quality surgical steel |
| Application | Phacoemulsification, clear corneal incision and incision preparation for intraocular lenses (IOL) |
| Use | Disposable, single-use |
| Compatibility | Hospitals, clinics and ophthalmic surgical centres |
| Presentation | Box of 6 units |
| Delivery time | 6-8 weeks |
| Reference | P-912868 |
Range of sharp angled double bevel blades for phacoemulsification:
| Reference | Blade width | Description |
| P-912868 | 2.8 mm | Sharp point angled 45° 19 gauge (double bevel), current data sheet |
| P-912968 | 3.0 mm | Sharp point angled 45° 19 gauge (double bevel) |
| P-913268 | 3.2 mm | Sharp point angled 45° 19 gauge (double bevel) |
4. Equivalences and Cross-References
This blade belongs to the family of angled sharp-pointed double bevel keratomes for corneal incision in phacoemulsification. Its function is comparable to that of angled clear corneal incision blades from leading ophthalmic manufacturers such as Katena, Storz / Bausch + Lomb, Sharpoint blades from Surgical Specialties (Corza Medical), KAI Medical and Malosa, although the exact equivalence of measurements, gauge and geometry must be confirmed according to the surgeon’s technique. In the Cahnos catalogue, the closest references are P-912968 (2.8 mm) and P-913268 (3.2 mm), from the same family of 45° angled double bevel 19 gauge; it is complemented by the straight double bevel (P-912808) and straight sharp point (P-912901) blades, as well as miniature spoon-type blades (P-6820, P-6821, P-6821E).
5. Selection tips and variants of interest
Select the blade width according to the planned incision: 2.8 mm (P-912868) for reduced access, 3.0 mm as the standard size for clear corneal incision in phacoemulsification (P-912968) and 3.2 mm (P-913268) when a slightly larger access is required. The 45° angle is especially useful in surgeries with limited eyelid opening or angled access, as it improves manoeuvrability without straining the surgeon’s wrist. If you prefer a straight approach with double bevel, consider the P-912808, or the P-912901 if you need a straight sharp point; for micro-incisions with a spoon-type edge, consider the P-6820, P-6821 and P-6821E variants. For incision widening in intraocular lens (IOL) surgery, the P-915xxx and P-916xxx series are also available. As this product is supplied to order with a delivery time of 6 to 8 weeks, we recommend planning the order by box of 6 units in advance to ensure availability in the operating theatre. For specific volumes or protocols, please consult our technical-commercial team, who will advise you on the most suitable reference for your surgical practice.






Reviews
There are no reviews yet.