Cahnos.com Compare invoice

Absorbable Monofilament Polydioxanone (PDO/PDS) Prime Suture · ½ Circle Cylindrical Body Needle Ultra Plus Conical Point HRP 48 mm · USP 0 Gauge · 150 cm Loop Thread · Violet · Ref. AMP415HRP48L10 – Box of 12 units

110,66 €

Absorbable suture monofilament of Polydioxanone (PDO/PDS) in Prime quality from the Premisut range, reference AMP415HRP48L10 (manufacturer P415HRP48L10). It mounts a ½ circle needle with cylindrical body and Ultra Plus conical point (Taperpoint) of 48 mm (HRP 48), USP 0 gauge (metric 3.5) and violet thread of 150 cm in loop format, ideal for continuous suturing without rethreading. Predictable absorption by hydrolysis between 180 and 210 days: tension retention of 75% at 2 weeks, 60-70% at 4 weeks and 45% at 8 weeks. Sterile by ethylene oxide, single-use, minimal tissue reaction and excellent knot security. Indicated for approximation of soft tissues, ligatures, general surgery, paediatric cardiovascular tissues, fascia closure and ophthalmology. Presentation in a box of 12 units.

International shipping. Import duties and taxes are payable by the recipient.

Reference
AMP415HRP48L10

Description

1. Product Presentation

The absorbable monofilament Polydioxanone (PDO/PDS) suture in Prime quality presented by Cahnos, reference AMP415HRP48L10, is the reference choice for hospitals, private clinics, operating theatres and purchasing centres looking for a long-lasting absorbable synthetic thread with a very competitive price-quality ratio. This presentation combines a ½ circle cylindrical body needle with an Ultra Plus (Taperpoint) conical point of 48 mm, USP 0 gauge and violet thread of 150 cm mounted in a loop. It is supplied sterile and ready to use, and is especially indicated for the approximation of soft tissues, ligatures, general surgery, paediatric cardiovascular tissues, fascia closure and ophthalmology, where prolonged wound support is required (tissues that take more than 6 weeks to regain their strength).

2. Technical Explanation

Polydioxanone is a synthetic absorbable polymer (poly(p-dioxanone)) that degrades by hydrolysis, i.e., by contact with organic fluids, with minimal inflammatory response and without depending on the patient’s enzymatic activity. Its monofilament structure facilitates passage through tissue with less friction and eliminates interstitial spaces, reducing the risk of bacterial colonisation compared to braided threads.

The ½ circle needle with cylindrical body and Ultra Plus conical point (Taperpoint profile) offers a progressive and atraumatic entry into soft tissues, separating the fibres without cutting them and minimising tissue damage even in deep planes and reduced surgical fields. The loop format allows placing the first stitch and anchoring the continuous suture without rethreading, a clinically relevant advantage in laparoscopic surgery and confined spaces. The violet colouration guarantees optimal visibility of the thread throughout the procedure. Sterile single-use product, not for re-sterilisation.

3. Technical Specifications

3.1. Technical data sheet for reference AMP415HRP48L10

Characteristic Specification
Reference (SKU) AMP415HRP48L10 (manufacturer ref. P415HRP48L10)
Range / Quality Premisut, Prime quality
Material Polydioxanone (PDO/PDS), synthetic monofilament
Gauge USP 0 (metric 3.5)
Thread colour Violet (high visibility)
Thread length 150 cm with loop
Needle shape ½ circle (1/2)
Needle body Cylindrical
Needle tip Conical Ultra Plus (Taperpoint)
Needle size 48 mm (HRP 48)
Absorption mechanism Hydrolysis
Absorption period 180-210 days
Sterilisation Ethylene oxide (EO), sterile, single-use
Tissue reaction Minimal
Indications Tissue approximation, ligatures, general surgery, paediatric cardiovascular tissues, fascia and ophthalmology
Presentation Box of 12 units

3.2. Tensile strength retention profile

Time after implantation Retained tensile strength
2 weeks 75 %
4 weeks 60-70 %
8 weeks 45 %

Complete absorption by hydrolysis between 180 and 210 days. Minimal tissue reaction, excellent tensile strength and optimal knot tying, with a fully predictable absorption rate. Price per box of 12 units.

4. Equivalences and Cross-References

Monofilament polydioxanone is a family of long-lasting absorbable sutures that is clinically comparable to the main lines on the international market. Below are listed the references from other commercial houses verified in the regulatory database (GUDID) and authorised distribution catalogues, in the configuration closest to the analysed reference (USP 0, 48 mm conical needle, 150 cm loop, violet):

Manufacturer / Brand Family / Model Reference Code / SKU Equivalence Level Technical Differences / Remarks
Ethicon (Johnson & Johnson MedTech) PDS II (polydioxanone without triclosan) – CTX conical needle ½ circle 48 mm, 150 cm loop, violet, USP 0 Z990G Comparable by category (not interchangeable 1:1) Same material (PDO), same USP 0 gauge, same needle geometry (½ circle, cylindrical body, 48 mm conical point), same 150 cm loop format and violet colour. They differ in the declared absorption profile (182-238 days for PDS II vs. 180-210 days) and the commercial house; verify batch and regulatory classification before substituting.
Ethicon (Johnson & Johnson MedTech) PDS Plus (polydioxanone with triclosan) – CTX conical needle ½ circle 48 mm, 150 cm loop, violet, USP 0 PDP9261G / PDP9261T Comparable by category (not interchangeable 1:1) Matching configuration in gauge, 48 mm conical point, 150 cm loop and violet colour, with the exception of the triclosan antimicrobial coating and a slightly broader declared absorption profile (182-238 days). Code PDP9261G verified in GUDID.

There is no equivalence table validated by the manufacturer for cross-brand matching in the exact configuration of Ultra Plus HRP 48 mm conical needle with 150 cm loop; consult the technical department before use in tenders. For any formal substitution, the material, gauge (USP 0), needle size and geometry (½ circle, cylindrical body, conical point, radius 48 mm), thread length and format (150 cm, loop), colour and regulatory classification of each reference must be verified one by one, since small variations in needle radius or thread length prevent a 1:1 equivalence. Within the same clinical category, the reference prolonged-absorption monofilament polydioxanone lines in the sector also include MonoPlus from B. Braun (violet polydioxanone suture, comparable at category level and not interchangeable 1:1; specific code pending confirmation against official catalogue).

5. Selection tips and variants of interest

The USP 0 gauge (metric 3.5) is very versatile: suitable for subcutaneous tissue, superficial muscle planes, fascia closure, abdominal wall and approximation of soft tissues with moderate tension. The Ultra Plus conical point offers an atraumatic entry ideal for soft tissues and delicate structures; if the procedure requires greater penetration into firm or fibrous tissues, consider a trocar point (Tapercut) needle from the same family and gauge. The 150 cm loop format is ideal for continuous suture or anchoring without rethreading.

Within the PDO family from Cahnos, the following variants of interest are available:

Reference Recommended variant
AMP415HRP48L01 PDO Prime USP 1, Ultra Plus HRP 48 mm conical needle, violet, 150 cm with loop (same needle, larger gauge)
AMP415HRP40L10 PDO Prime USP 0, Ultra Plus HRP 40 mm conical needle, violet, 150 cm with loop (same configuration, shorter needle)
AMP415HRT48L10 / AM415HRT48L10 PDO USP 0, Tapercut HRT 48 mm trocar needle, violet, 150 cm with loop (greater penetration in firm tissues)
AMP413HRP4801 PDO Prime USP 1, Ultra Plus HRP 48 mm conical needle, violet, 90 cm (same needle, short thread without loop)

All references are supplied in boxes of 12 units. As this is a sterile single-use product, check the integrity of the packaging before each procedure, respect the expiry date and store the suture in a cool, dry place, protected from sunlight. For special B2B conditions by volume, hospital supply contracts or equivalents from other commercial houses, contact our technical-commercial team.

Additional information

Material

Polydioxanone (PDO/PDS), synthetic monofilament

Quality range

Premisut, Prime quality

Gauge

USP 0 (metric 3.5)

Thread length

150 cm with loop

Needle shape

½ circle, cylindrical body

Needle tip

Conical Ultra Plus (Taperpoint)

Needle size

48 mm (HRP 48)

Sterilisation

Ethylene oxide (EO), single-use

Use

Sterile, single-use

Presentation

Box of 12 units

Manufacturer reference

P415HRP48L10

Medida de aguja

HRP 48

Usp

0

Color

Violet

Medida de hilo

150 cm

Tipo de aguja

Cylindrical, Cylindrical flat tip

Forma de aguja

1/2 circle

Calidad sutura

Prime

Absorcion

Slow absorbable (> 120 days)