Description
Easydrop is the protected waste container that your Nuclear Medicine or Radiology department needs to safely manage the radioactive waste generated on a daily basis. Designed to store, contain and facilitate the decay of contaminated and radioactive healthcare waste, this unit combines a 20 mm lead biological shielding, an easily decontaminable ABS plastic construction and exceptional mobility thanks to its four sturdy wheels. A robust, practical solution backed by a leading European manufacturer such as Lemer Pax, designed to protect the operator without compromising workflow agility.
Technical explanation of the equipment
The Easydrop container acts as a containment point and temporary storage for solid radioactive waste (syringes, vials, labelling kits and contaminated consumables) generated in SPECT and PET nuclear medicine activities. Its 20 mm lead shielding effectively attenuates the gamma radiation emitted by the most common low- and medium-energy radiopharmaceuticals, such as technetium-99m (Tc-99m) or iodine-131 (I-131), reducing the occupational dose received by staff according to the ALARA principle (keeping doses as low as reasonably achievable).
The sliding opening lid allows the width of the opening to be adjusted to suit the size of the waste deposited, limiting the radiation cone to which the operator is exposed during each operation. The body, made entirely of white ABS plastic, can be fully cleaned, disinfected and decontaminated when required, complying with the hygiene protocols of controlled areas. Its four sturdy wheels facilitate movement and positioning of the unit in the required room, while the internal support ensures the bag is held securely during use.
Technical specifications
The Easydrop container is available in two capacities with the following reference configuration:
| Characteristic | Easydrop 20 L | Easydrop 54 L |
|---|---|---|
| Usable capacity | 20 L | 54 L |
| Overall dimensions | L 462 x D 481 x H 797 mm | L 562 x D 581 x H 797 mm |
| Internal dimensions | L 200 x D 200 x H 500 mm | L 300 x D 300 x H 600 mm |
| Radiation protection | 20 mm lead | 20 mm lead |
| Weight | 180 kg | 296 kg |
| Material | ABS plastic, easy to decontaminate | |
| Mobility | 4 sturdy wheels | |
General product data:
| Characteristic | Detail |
|---|---|
| Model | Easydrop (Lemer Pax) |
| Reference | CAH-LEM00015828 |
| Main function | Safe storage of radioactive waste |
| Opening system | Sliding lid with partial or full opening |
| Energy range | Low and medium energy (radiopharmaceuticals such as Tc-99m, I-131) |
| Applications | Nuclear Medicine, Radiology and Radiopharmacy |
| Presentation | Sold per unit |
Equivalences and cross-references
The Easydrop belongs to the family of shielded bins and containers from the European manufacturer Lemer Pax for the management of radioactive waste in nuclear medicine. The manufacturer’s original references for the Easydrop+ series are: 00045760 (low/medium energy 20 L), 00045761 (low/medium energy 54 L), 00045762 (low/medium energy 80 L), 00045763 (high energy 20 L) and 00045764 (high energy 54 L), all with 10 or 20 mm lead shielding, configurable according to the isotope and required capacity.
Within the Cahnos catalogue, the closest functionally equivalent solution is the Easydrop shielded bin (CAH-LP00015828), which extends the range to the 80 L capacity with sliding opening. Likewise, the shielded bins with wheels Medi 64 (CAH-LP00034045 in LME version and CAH-LP00034046 in HE version) offer the same functionality for collecting and transporting radioactive waste in nuclear medicine and radiology, with compatibility with DASRI boxes. For the containment of sharps waste, the Medisharp containers (CAH-LP00034047 and CAH-LP00034048) and PRA10 (CAH-LPPRA10) or PRA3 (CAH-LPPRA3) constitute complementary alternatives with lower capacity. Please consult our technical-commercial team to verify the exact equivalence according to the volume and activity of your facility.
Selection tips and variants of interest
To choose the most suitable configuration of the Easydrop, consider the following criteria:
- Energy level of the radiopharmaceutical: the 20 mm of lead in this reference offer effective attenuation for low- and medium-energy applications (Tc-99m, I-131). If your department handles high-energy PET emitters (F-18, Ga-68), consult the specific high-energy versions of the same family.
- Waste volume: the 20 L capacity is ideal for low-throughput generation points or compact radiopharmacies; the 54 L capacity is recommended for injection rooms and units with medium or high activity.
- Regulations and radiation protection: the selection of shielding must always be validated with the centre’s radiation protection service based on the area’s design dose calculation.
- Complementarity: combine the Easydrop with the Medi 64 shielded bins, the Medisharp needle containers or the RadWaste shielded container (CAH-CBR-60-20) to form a complete radioactive waste management circuit, from the injection room to the final removal of the material.