Syringe shield of high-density tungsten from the Mediclic LME range by Lemer Pax, designed for the preparation, measurement and injection of low and medium energy radiopharmaceutical substances in Nuclear Medicine services. Its 2 mm tungsten shielding with a 6 mm lead glass window effectively attenuates the gamma radiation of isotopes such as 99mTc, 111In, 123I, 201Tl or 177Lu, while maintaining optimal visibility of the graduations. Compatible with all syringes on the market, it features a one-click insertion and removal system and is fully disassemblable by the operator for easy decontamination or glass replacement. Ergonomic design, easy maintenance and compliant with the ALARA principle.

International shipping. Import duties and taxes are payable by the recipient.

Reference
CAH-LP11453

Description

1. Introduction

In Nuclear Medicine and Radiopharmacy services, every manipulation of a syringe loaded with a radiopharmaceutical poses a potential exposure to the professional’s hands and trunk. The Mediclic LME syringe shield from Lemer Pax, distributed by Cahnos, is the reference solution for working safely, comfortably and precisely with low and medium energy radiopharmaceutical substances. Made of high-density tungsten, it combines effective radiological protection with careful ergonomics, and is designed to accompany all stages of the process: preparation, transfer, measurement and injection of the dose.

2. Technical explanation of the equipment

The Mediclic LME acts as a biological barrier between the radioactive source and the operator. Its high-density tungsten body, with a thickness of 2 mm, combined with a 6 mm lead glass window, effectively attenuates the gamma radiation emitted by the most common low and medium energy radionuclides in SPECT scans, such as technetium-99m (140 keV), indium-111, iodine-123, thallium-201 or lutetium-177, reducing the dose received in hands and trunk throughout the entire handling.

The design incorporates a large lead glass window that allows the volume contained in the syringe and its graduations to be observed with total clarity, facilitating precise dose measurement and minimising errors. The one-click syringe insertion and removal system secures the syringe safely and quickly during direct injection into the patient, connection to a catheter or a three-way stopcock. In addition, the shield can be completely disassembled by the operator himself to facilitate decontamination or glass replacement, without the need for special tools or downtime, complying with the ALARA principle (keeping doses as low as reasonably achievable).

3. Technical Specifications

Parameter Specification
Product Shielded syringe protector for low and medium energy
Manufacturer Lemer Pax (France)
Range Mediclic LME (Low & Medium Energy)
Shielding material High-density tungsten
Radiation protection 2 mm tungsten + 6 mm lead glass
Viewing window Large lead glass for reading graduations
Energy range Low and medium energy (SPECT gamma emitters)
Compatibility All syringes on the market (common volumes from 1 to 10 ml)
Insertion system Introduction and removal of the syringe in one click
Maintenance Full disassembly by the operator for decontamination or glass replacement
Protection principle ALARA
Application Preparation, measurement and injection of radiopharmaceuticals in Nuclear Medicine
Reference (SKU Cahnos) CAH-LP11453

Compatible low and medium energy radiopharmaceuticals:

Radionuclide Main energy Typical application
Technetium-99m (99mTc) 140 keV SPECT diagnostics
Indium-111 (111In) 171/245 keV SPECT and cell labelling
Iodine-123 (123I) 159 keV SPECT
Thallium-201 (201Tl) 135/167 keV Perfusion SPECT
Lutetium-177 (177Lu) 208 keV Theranostics

4. Equivalences and Cross-References

The Mediclic LME shares its range with the Mediclic HE (CAH-LP11653), also from Lemer Pax, differing exclusively in the shielding thickness according to the energy spectrum of the radiopharmaceutical: 2 mm of tungsten and 6 mm of lead glass for low and medium energy, compared to 5 mm of tungsten and 9 mm of lead glass for high energy. Within the Cahnos catalogue, its direct equivalent is the Easyview LME range (CAH-LEM21896), with a minimum shielding of 2 mm of tungsten and an 8 mm lead glass window.

Related product Manufacturer Reference Cahnos Notes
Easyview LME Lemer Pax CAH-LEM21896 Direct equivalent for low and medium energy
Mediclic HE Lemer Pax CAH-LP11653 High energy version (PET and 131I)
Easyview HE Lemer Pax CAH-LEM24946 High energy, non-magnetic, suitable for PET-MRI
SyringeShield Pro Cahnos CAH-SSP Low and medium energy with storage support
Easysqueeze Lemer Pax CAH-LP00008664 Flexible shield for manual injection
Beta emitter shield Cahnos CAH-BSS-MIX-BE Mixed shielding of tungsten, PMMA and lead glass

It corresponds functionally to the low and medium energy syringe shields from other radiation protection manufacturers, including the RADIOPROTECH range. For the transport of already loaded syringes, the complementary systems in the range are recommended: shielded syringe holder SC10 (CAH-LPSC10), EasyBOX Carrier case (CAH-LEM13222) and Crocobox briefcase (CAH-LM00038013).

5. Selection tips and variants of interest

To choose the appropriate configuration of the Mediclic LME range, check the radionuclide being handled and its energy spectrum (the usual low and medium energy ones: 99mTc, 111In, 123I, 201Tl and 177Lu), as well as the volume and length of the syringes used in your protocols; the range is compatible with all syringes on the market. If your department also handles high energy PET-type emitters (18F-FDG, 68Ga) or 131I, consider incorporating the high energy version of the family: Mediclic HE (CAH-LP11653) or Easyview HE (CAH-LEM24946), to adapt the protection to the energy spectrum of each isotope.

Plan the periodic replacement of the lead glass according to the frequency of use and take advantage of the complete disassembly for thorough decontamination and simple maintenance. Complete your comprehensive radiation protection strategy with vial shields (PFE/PME/PHE), bench and injection shields, PRA3/PRA10 needle containers and shielded transport systems. Our technical-commercial team can advise you on the optimal configuration for your centre and process customised quotes for comprehensive supply projects.

Additional information

Manufacturer

Lemer Pax (France)

Shielding material

High-density tungsten

Radiation protection

2 mm tungsten + 6 mm lead glass

Viewing window

Large lead glass for reading graduations

Energy range

Low and medium energy (SPECT gamma emitters)

Syringe compatibility

All syringes on the market (1 to 10 ml)

Introduction system

Insertion and removal of the syringe in one click

Maintenance

Full disassembly by the operator for decontamination or glass replacement

Protection principle

ALARA

Application

Preparation, measurement and injection of radiopharmaceuticals in Nuclear Medicine

Presentacion

Unit

Reviews

There are no reviews yet.

Be the first to review “Mediclic LME (Lemer Pax) – Tungsten syringe shield for low and medium energy radiopharmaceuticals | 2 mm shielding and 6 mm lead glass | Nuclear Medicine”

Your email address will not be published. Required fields are marked *