We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice

Posijet® Lemer Pax | Automatic Injector for Radiopharmaceuticals: Independent Fractionation and Injection Unit for Nuclear Medicine and Radiology

Price on request

Heavy / bulky product. Shipping is neither free nor included in the price: it depends on the destination, Cahnos subsidises part of it and we will confirm the cost separately after your order. If you need it before buying, please contact us.

Posijet® is the independent fractionation and injection unit from Lemer Pax for low, medium and high energy radiopharmaceuticals in Nuclear Medicine and Radiology departments. Designed to prepare, measure and inject automatically and safely doses of 18F-FDG, FDopa, NaF, FCholine, 68Ga, 13N, 99mTc and 177Lu, it achieves 100 % efficiency of the stock solution with a precision of ±2 %. Its integrated shielding and closed circuit minimise operator exposure (less than 25 µSv/h at 5 cm), with an average dose preparation time of about 50 seconds and injection in less than 1 minute and a half.

International shipping. Import duties and taxes are payable by the recipient.

Reference
CAH-LP0019530

Description

1. Posijet®: automation and safety in the preparation and injection of radiopharmaceuticals

Posijet® is the result of a continuous improvement process by Lemer Pax, world leader in radiation protection, to offer an automatic injector that meets the real needs of Nuclear Medicine and Radiology departments: maximum operator protection, absolute efficiency in the use of the radiopharmaceutical and complete traceability of each administered dose. It is a self-contained, compact and mobile unit that fractionates multi-dose vials, measures the activity and administers the exact dose to the patient under the highest safety conditions for staff and for the patient themselves, guaranteeing the integrity of the radioactive medicinal product.

Its integrated shielding, closed circuit and ergonomic design with motorised assistance make it the most versatile solution on the market for protected preparation and injection, both for PET and SPECT diagnostic radiopharmaceuticals and for new therapeutic applications.

2. Technical explanation of the equipment and procedure

Posijet® integrates the preparation, measurement and injection stages into a single self-contained unit. The multi-dose vial is introduced directly into the equipment in its shielded transport container (e.g. Lemer Pax Posisafe-type containers), so that the stock solution always remains shielded. Using a high-precision sampling head, the equipment draws the required amount of solution (minimum sampling volume of 100 µL), transfers it to a 10 mL syringe and measures it in real time with the integrated Scintidose dose calibrator, which requires no warm-up time and offers an accuracy of ±2 %.

  • Fractionation and dilution: dilution function available at any point in the cycle, optimised or customised, to make full use of 100 % of the stock solution and facilitate the collection of residual activity from the vial.
  • Mixing and vial pressure: mixing function with saline after high dilutions and automatic adjustment of vial pressure to improve dose accuracy.
  • Controlled injection: automatic or manual modes, three speed profiles (slow, normal and fast), real-time air bubble detector, anti-overpressure force sensor, automatic purge and configurable post-injection flush of 10 to 30 mL of physiological saline.
  • Total traceability: kit barcode reader, integrated web application, generation of injection reports on customisable labels and data log exportable in CSV or XML format.
  • Hospital connectivity: bidirectional interface with radiopharmacy software (Venus, PharmaManager, Gera, Xplore) and with RIS/PACS systems via HL7 and DICOM protocols, as well as WiFi and Ethernet connection for remote maintenance.

3. Technical Specifications

3.1 General characteristics

Parameter Value
Dimensions (width x depth x height) 616 x 932 x 1261 mm
Unit weight 380 kg
Electrical supply 110-240 V, 50/60 Hz
Power source Mains or battery (8 h autonomy, 3 h charge)
User interface Touch screen; USB port; WiFi and Ethernet connectivity
Mobility Motorised assistance with independent battery, one-hand rotary control, speed up to 2 km/h; pedal brake
Finishes 15 customisable colours and designs, possibility to integrate the department logo
Application languages French, English, Italian, Russian and Chinese (others on request); units MBq or mCi
Transport packaging L 850 x D 1500 x H 1580 mm; 520 kg

3.2 Shielding and radiation protection

Parameter Value
Shielding around the sampling syringe 25 mm lead equivalent
Shielding around the solution vial 12 to 16 mm lead equivalent
Guaranteed dose rate Less than 25 µSv/h at 5 cm from the walls during preparations (operator behind the console)
Manageable activity (18F) Up to 37 GBq if the vial is kept in its 30 mm lead container
Applied principle ALARA: as low as reasonably achievable
Waste container Integrated waste bin with specific shield for 20 mL syringe

3.3 Dose preparation and measurement

Parameter Value
Utilisation efficiency 100 % of stock solution used
Measurement accuracy ±2 %
Minimum sampling volume 100 µL
Average dose preparation time 50 seconds
Maximum activity per patient dose 500 MBq (configurable value)
Maximum vial activity concentration 3 GBq/mL
Integrated measuring instrument Scintidose activimeter (class Im medical device), always operational with no warm-up time
Advance preparation Timer function from 0 to 10 minutes with automatic decay adjustment
Prescription calculation Automatic based on weight, body surface area or BMI

3.4 Injection

Parameter Value
Average injection time (with flush) Less than 1 minute and 30 seconds
Injection modes Automatic or manual, modifiable during injection
Speed profiles Slow (≈25 mL/min), normal (≈33 mL/min), fast (≈50 mL/min), depending on catheter and location
Post-injection flush From 10 to 30 mL of physiological saline, user-configurable
Injection safety Air bubble detector, force sensor with overpressure stop and vein test function
Drug integrity 0.22 µm filter at the patient kit outlet ensuring sterility
Reports Customisable injection labels in size and information (2 formats)

3.5 Compatible radioisotopes

Isotope Application / tracers
18F Multidose fluorinated tracers: FDG, FNA, FDOPA, FCHOLINE, PSMA, etc. (PET)
13N Ammonia labelled with 13N for cardiac PET
68Ga Gallium-68 labelled tracers (high energy)
99mTc SPECT radiopharmaceuticals labelled with technetium-99m
177Lu Vectorised therapy (VIR/TER): 177Lu-DOTATATE, 177Lu-PSMA-617, slow infusions over 30 minutes

3.6 Regulations and compliance

Standard Detail
EU Regulation 2017/745 Class IIb medical device (notified body), class Im activimeter
IEC 60601-1:2005 (+A1/2012) (+A2/2020) General safety of electromedical equipment
IEC 60601-1-2:2014 (+A1/2020) Electromagnetic compatibility
IEC 62304:2006 (+A1/2015) Software life cycle of the activimeter control
IEC 61948-4 Activimeter inspection functions
EU Regulation 2016/679 Data protection (GDPR), suitable for hospital network
Paediatric use Certified for paediatric patients over 1 year old (specific version)
Calibration Factory-set for 18F and 68Ga; optional by COFRAC accredited body ISO 17025

3.7 Consumables, accessories and options

Item Description
POSIKIT 1B stock solution kit Single-use kits for connecting the multidose vial (consumable reference)
POSIKIT 2 patient kit Patient kit with bubble trap, non-return valves and 0.22 µm filter
Therapy option 177Lu application for vectorised therapy with controlled slow administration
Pre-calibrated activimeter option COFRAC pre-calibrated activimeter (ISO 17025)
RIS option Remote injection system with Minijet for peripheral injection and two simultaneous injections
Paediatric version Packaging, application and safety parameters adapted for patients >1 year

4. Equivalences and Cross-References

This equipment corresponds to the manufacturer reference Lemer Pax 00019530, which is supplied under the configurations 00019530-CAL and 00019530-ET (with calibrated dose calibrator). The official consumables for the equipment are the stock solution kit POSIKIT 1B and the patient kit POSIKIT 2, Lemer Pax’s own references that must be ordered separately.

Within the Cahnos catalogue, Posijet® is complemented by the shielded containers from the same Lemer Pax family, compatible with the equipment for direct introduction of the vial in its transport pot: the Posisafe® Pb 30 Type A (SKU CAH-LP00028672), with 30 mm lead shielding, and the Posisafe® W Type A (SKU CAH-LP00017444), in high-density tungsten for environments where weight is critical.

Product Reference Relationship with Posijet®
Posijet® (fractionation and injection unit) 00019530 / 00019530-CAL / 00019530-ET (SKU CAH-LP0019530) Main product
Posisafe® Pb 30 Type A CAH-LP00028672 30 mm lead container for introducing the multi-dose vial into Posijet®
Posisafe® W Type A CAH-LP00017444 Tungsten alternative for transport and insertion of the vial
POSIKIT 1B / POSIKIT 2 Lemer Pax Consumables Single-dose stock solution and patient kits

In terms of interoperability, Posijet® is compatible with the main radiopharmacy software programs on the market (Venus by Nicesoft, PharmaManager by Softway Medical, Gera by Thélème and Xplore by EDL) and with Sectra RIS systems and Comecer NM modules via HL7 protocol, as well as with PACS via DICOM, ensuring integration into any hospital infrastructure.

5. Selection tips and variants of interest

  • Assess the type of energy and tracers: if your department mainly handles FDG and conventional PET, the standard diagnostic configuration is sufficient; if you work or plan to work with 177Lu in vectorised therapy, request the therapy application option (specific menu with registered protocols and accuracy exceeding 99 % of the prescription).
  • Confirm the workload: the average preparation time of 50 seconds and injection in less than 1 minute and a half, together with the advance preparation timer function, allow for absorbing dense patient schedules; consider the RIS option if you need simultaneous or peripheral injections.
  • Plan the consumables: budget for the POSIKIT 1B (stock solution) and POSIKIT 2 (patient) kits, as well as physiological saline bags for purges, dilutions and flushes (10-30 mL per injection).
  • Complete the workflow with compatible containers: choose Posisafe® Pb 30 for low and medium energy or Posisafe® W Type A (tungsten) when transport weight is a determining factor; the vial can be inserted into the equipment directly inside its shielded container.
  • Take into account installation and support: the unit requires a 110-240 V mains supply, has remote maintenance and offers optional COFRAC calibration (ISO 17025); consult our technical-commercial team regarding commissioning, training and maintenance contract.
  • Paediatric population: if you treat paediatric patients, request the specific version (>1 year), with dose thresholds configurable by protocol and additional age-related protection.

Additional information

Manufacturer

Lemer Pax

Manufacturer reference

00019530 (00019530-CAL / 00019530-ET)

Product type

Radiopharmaceutical fractionation and injection unit

Dimensions

616 x 932 x 1261 mm (width x depth x height)

Weight

380 kg

Power supply

110-240 V, 50/60 Hz, mains or battery (8 h autonomy)

Shielding

25 mm around the sampling syringe; 12-16 mm around the vial

Measurement precision

±2 %

Stock solution efficiency

100 %

Minimum sampling volume

100 µL

Maximum patient dose activity

500 MBq (configurable)

Maximum vial concentration

3 GBq/mL

Compatible radioisotopes

18F (FDG, FNA, FDOPA, FCHOLINE, PSMA), 13N, 68Ga, 99mTc, 177Lu

Measuring instrument

Integrated Scintidose activimeter (class Im)

Injection profiles

Slow ≈25 ml/min, normal ≈33 ml/min, fast ≈50 ml/min

Post-injection flush

10-30 mL of configurable saline solution

Consumables

POSIKIT 1B (stock solution), POSIKIT 2 (patient)

Options

Therapy application 177Lu, COFRAC activimeter ISO 17025, RIS with Minijet, paediatric version >1 year

Regulatory standard

EU Regulation 2017/745 class IIb; IEC 60601-1, IEC 60601-1-2, IEC 62304, IEC 61948-4

Connectivity

WiFi, Ethernet, HL7, DICOM; software Venus, PharmaManager, Gera, Xplore

Presentation

Unit with calibrated activimeter; consumable kits sold separately

Reviews

There are no reviews yet.

Be the first to review “Posijet® Lemer Pax | Automatic Injector for Radiopharmaceuticals: Independent Fractionation and Injection Unit for Nuclear Medicine and Radiology”

Your email address will not be published. Required fields are marked *