We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice

TheranoJet®ARA from Lemer Pax – Shielded injection pump shield for theranostic radiopharmaceuticals (177Lu) in Nuclear Medicine and Radiology

Price on request

Heavy / bulky product. Shipping is neither free nor included in the price: it depends on the destination, Cahnos subsidises part of it and we will confirm the cost separately after your order. If you need it before buying, please contact us.

The TheranoJet®ARA from Lemer Pax (ref. 00050009) is a shielded injection pump shield designed for the radioprotected intravenous administration of radiopharmaceuticals intended for targeted internal radiotherapy (RIV/RPT), especially those labelled with lutetium-177 (177Lu). Manufactured entirely from 304L stainless steel, it incorporates a bidirectional infusion pump with air bubble and overpressure detector, removable containment tray, rotating vial holder with a 30 ml shielded shield and leaded organic screen, on a mobile structure with 4 double wheels and adjustable side handles. Light, versatile and with quick consumable installation, it guarantees maximum operator and patient safety during injection in Nuclear Medicine and Radiology departments.

International shipping. Import duties and taxes are payable by the recipient.

Reference
CAH-00050009

Description

1. Commercial Introduction

The TheranoJet®ARA is the reference shielded injection system from the French manufacturer Lemer Pax for Nuclear Medicine and Radiology departments performing radiopharmaceutical therapies. Developed in collaboration with the Beaujon AP-HP Hospital in Paris, this injection pump shield allows the intravenous administration of radiopharmaceutical products for vectorised internal radiotherapy (RIV), also known as radioligand therapy (RLT) or radiopharmaceutical therapy (RPT), particularly labelled with lutetium-177 (177Lu). It is a single-use per patient, lightweight, mobile and versatile solution, designed to protect healthcare staff throughout the entire injection procedure without compromising patient comfort.

2. Technical explanation of the equipment

The TheranoJet®ARA acts as a mobile biological barrier between the radioactive source and the operator, integrating into a single stainless steel 304L structure all the elements necessary for the safe administration of the radiopharmaceutical. The vial is placed in a shielded vial shield (30 ml) mounted on a rotating support that allows the vial to be inverted, ensuring complete administration of the contents and facilitating rinsing of the vial by inversion, which recovers residual activity and transfers it to the patient.

The bidirectional infusion pump incorporates a high-pressure detector and an air bubble detector, avoiding the risk of extravasation or air injection; its configurable screen allows the flow rate to be adapted to each clinical protocol. The connection to the vial is made via a sterile needle-free transfer system, which minimises the risk of contamination and accidental needlestick injuries. The equipment has a removable containment tray that retains the radiopharmaceutical in the event of any incident and facilitates microbiological and radioactive decontamination without altering the components of the unit, as well as a transparent organic protective screen that allows the line and retention area to be visualised at all times.

3. Technical Specifications

General characteristics

Parameter Specification
Product Shielded injection pump shield for theranostic products
Manufacturer Lemer Pax (France)
Manufacturer reference 00050009
External dimensions (with drip stand) L 712 x D 759 x H 1,760 mm
Material Frame and drip stand in stainless steel 304L
Weight 86 kg
Mobility 4 twin castors (2 with brake), 2 side handles with height-adjustable grip
Protection principle ALARA (as low as reasonably achievable)

Shielding and radiological protection

Item Specification
Transparent organic screen 0.5 mm lead eq. (dimensions L 220 x H 170 mm)
Lower protective housing Lead, eq. 2 mm
Shielded vial shield (ref. 00050036) Lead glass + lead; vial volume 30 ml; weight with lid 3.1-3.9 kg
Maximum manageable activity 7,400 MBq of 177Lu for a dose rate below 100 µSv/h at 5 cm from the walls

Compatible radionuclides

Therapy type Radionuclides
Targeted internal radiotherapy (RIV/RPT) 177Lu, 161Tb, 223Ra, 225Ac, 212Pb, 211At

Integrated equipment and options

Component Reference
Bidirectional injection pump Integrated
Patient injection kit 00055414
Shielded vial shield 00050036
Shielded connection system for the vial shield 00051943
Forceps for removing the vial shield connection 00055988
Shielded decay cover 00054547
Shielded container for transporting the vial shield (option) 00051923

4. Equivalences and Cross-References

The TheranoJet®ARA corresponds to the factory reference 00050009 from Lemer Pax, marketed by Cahnos under the code CAH-00050009. Its associated shielded vial shield (ref. 00050036) is a specific component of this system, although functionally it can be compared with the medium-energy radiopharmaceutical vial shields available in the Cahnos catalogue, such as the VialShield Pro (CAH-VSP), the 20 mm leaded glass container protector (CAH-LP0016) or the mixed PMMA/lead/leaded glass vial shields (CAH-BVS-MIX-BME).

For the protection of syringes in the preliminary phases of dose preparation and measurement, it is recommended to complete the workflow with tungsten syringe shields from the same Lemer Pax family: Mediclic LME (CAH-LP11453), Mediclic HE (CAH-LP11653) or the Easyview range (CAH-LEM21896 and CAH-LEM24946). For the transport of loaded vials and syringes between the radiopharmacy and the injection room, the catalogue offers syringe carriers and shielded cases such as the SC10 (CAH-LPSC10), the EasyBOX Carrier (CAH-LEM13222) and the Crocobox case (CAH-LM00038013).

5. Selection tips and variants of interest

Before integrating the TheranoJet®ARA into your department, verify the radionuclide and activity of your protocols: the equipment is optimised for RIV therapy labelled with 177Lu (up to 7,400 MBq) and supports other emitters such as 161Tb, 223Ra, 225Ac, 212Pb and 211At, as well as some diagnostic protocols. Confirm the compatibility of the vial shield with the 30 ml vials used in your radiopharmacy and consider acquiring the shielded transport container (option ref. 00051923) to move the vial safely from the hot cell to the injection room.

Plan the replenishment of consumables, especially the patient injection kit (ref. 00055414) and the needle-free sterile connection systems, as well as periodic decontamination using the removable tray. If your department combines therapy and diagnostics, complete your comprehensive radiation protection strategy with syringe shields, vial shields, transport cases and waste containers from the Cahnos range. Our technical-commercial team can advise you on the optimal configuration for your centre and process customised quotes for comprehensive equipment projects in Nuclear Medicine and Radiology.

Additional information

Manufacturer

Lemer Pax (France)

Manufacturer reference

00050009

Product type

Shielded injection pump shield (single-use shielded injection system)

Dimensions

L 712 x D 759 x H 1,760 mm (with drip stand)

Weight

86 kg

Material

Stainless steel 304L (frame and drip stand); lead shielding with leaded organic screen

Upper shielding

Transparent organic screen: 0.5 mm lead eq.

Lower shielding

Lower lead housing: 2 mm lead eq.

Protective screen

L 220 x H 170 mm

Maximum activity

7,400 MBq of 177Lu (dose rate below 100 µSv/h at 5 cm from the walls)

Compatible radioisotopes

177Lu, 161Tb, 223Ra, 225Ac, 212Pb, 211At

Infusion pump

Bidirectional with high-pressure, obstruction and air bubble detection

Mobility

4 twin castors (2 with brake) and 2 side handles with height-adjustable grip

Vial protector

16 mm lead glass + 7 mm lead; 30 mL vial; 3.1 kg (ref. 00050036)

Patient injection kit

Ref. 00055414

Decay cover

Ref. 00054547

Packaging

L 1250 x P 800 x H 650 mm; 200 kg (ref. 00051923)

Presentation

Complete unit with injection pump, shielded vial protector and integrated accessories

Protection principle

ALARA

Application

Radiation-protected intravenous administration of radiopharmaceuticals for vectorised internal radiotherapy (RIV/RPT) labelled with 177Lu

Radionuclides

177Lu, 161Tb, 223Ra, 225Ac, 212Pb, 211At

Shielding

Transparent organic screen 0.5 mm lead eq.; lower lead housing eq. 2 mm

Pump

Bidirectional infusion pump with air bubble detector and high-pressure detector

Vial shield

Shielded vial shield, 30 ml (ref. 00050036) with rotating support and vial inversion

Includes

Injection pump, patient injection kit, vial shield, shielded connection system, removal forceps and shielded decay cover

Use

Nuclear Medicine and Radiology services with theranostic therapies and radiopharmaceuticals

Reviews

There are no reviews yet.

Be the first to review “TheranoJet®ARA from Lemer Pax – Shielded injection pump shield for theranostic radiopharmaceuticals (177Lu) in Nuclear Medicine and Radiology”

Your email address will not be published. Required fields are marked *