1. Commercial Introduction
In Nuclear Medicine services, each administration of a radiopharmaceutical demands precision, safety and absolute dose control. The Manual Radiopharmaceutical Injection Unit (SKU CAH-856) is the professional solution that integrates into a single system the dispensing of the unit dose and its manual administration to the patient. Designed for radiopharmacists, nuclear medicine technicians and nursing staff, it allows comfortable, ergonomic work with effective radiological protection in the critical phases of preparation, measurement and injection, reducing occupational exposure to hands and extremities without compromising visibility or control of the plunger.
2. Technical explanation of the equipment and procedure
The unit acts as a manual dispensing and administration system: the unit dose of radiopharmaceutical is aspirated with the loaded syringe, fixed stably in the shielded receptacle and administered directly to the patient via the included administration system. The high-density tungsten shielding effectively attenuates gamma radiation, while the holder with locking position keeps the syringe immobile during measurement and injection, ensuring that each dispensed dose is stable, reproducible and traceable. This design responds to the ALARA principle (keeping doses as low as reasonably achievable) and is compatible with the standard 5, 10 and 20 ml syringes commonly used in radiopharmacy for gamma camera examinations and SPECT procedures.
3. Technical Specifications
The main specifications of the Manual Radiopharmaceutical Injection Unit with dose administration system are detailed below:
| Parameter | Specification |
|---|---|
| Device type | Manual injection unit with dose administration system |
| Main function | Dispense a unit dose of radiopharmaceutical and administer it manually to the patient |
| Administration mode | Manual, with direct control of the plunger by the professional |
| Syringe compatibility | 5, 10 and 20 ml (standard radiopharmacy syringes) |
| Protective material | High-density tungsten (radiological shielding) |
| Holding system | Holder with locking position for stability during measurement and injection |
| Protection principle | ALARA (as low as reasonably achievable) |
| Scope of use | Nuclear Medicine, hospital radiopharmacy and preparation and injection rooms |
| Maintenance | Smooth surfaces for easy cleaning and decontamination |
| Presentation | Manual injection unit + dose administration system |
4. Equivalences and Cross-References
This manual injection unit functionally corresponds to the syringe shields and holders of the RADIOPROTECH radioprotection range, a leading European manufacturer distributed by Cahnos, as well as to the syringe shields with leaded glass window for low, medium and high energy on the market, including the Mediclic and Easyview models from Lemer Pax (available at Cahnos under references CAH-LP11453 and CAH-LEM21896 in their low and medium energy versions, and CAH-LP11653 and CAH-LEM24946 in high energy) and the shielded syringe shield Easysqueeze (CAH-LP00008664), the latest standard in manual injection. In the radioprotected workflow, this system is complemented by the SyringeShield Pro Shielded Syringe Shield (CAH-SSP), the Beta Emitter Syringe Shield (CAH-BSS-MIX-BE), the VialShield Pro Shielded Vial Shield (CAH-VSP), the shielded syringe holders SC10 (CAH-LPSC10) and the Crocobox transport cases (CAH-LM00038013). For services with high workload requiring full automation, the family is extended with the Posijet® automatic injector from Lemer Pax (CAH-LP0019530), which fractionates, measures and administers doses with full traceability.
5. Selection tips and variants of interest
To choose the most suitable configuration for your service, consider the following recommendations:
- Verify the volume and length of the syringes used in your protocols (5, 10 or 20 ml) to confirm compatibility with the unit’s receptacle.
- Assess the energy spectrum of your radiopharmaceuticals: for low and medium energy emitters, the standard tungsten shielding is sufficient; if you regularly work with high energy PET tracers (18F, 68Ga, 13N), consult the high energy versions of the same family.
- Plan routine cleaning and decontamination of the equipment according to your radiopharmacy protocols and periodically check the condition of the shielding and locking system.
- Complete your comprehensive radiation protection strategy with vial shields, bench and injection shields, syringe holders and shielded transport systems, ensuring protection throughout the entire radiopharmaceutical handling chain.
- Our technical-commercial team can advise you on the optimal configuration for your centre and manage personalised budgets for comprehensive supply projects.