Description
1. Commercial Introduction
In Nuclear Medicine departments, every operation of preparation, aliquoting, dispensing and injection of radiopharmaceuticals exposes the healthcare professional to radiation that must be reduced to a minimum following the ALARA principle (keeping doses as low as reasonably achievable). The height-adjustable mobile protective shield BPP 30 HV from Lemer Pax, distributed by Cahnos under the reference CAH-LPBPP30 HV, is the mobile radiation protection solution your department needs: a robust, stable and easy-to-move biological barrier that combines maximum attenuation with a perfect view of the work area. Specifically designed for PET environments and preparation and injection rooms, it protects the operator against high-energy radiation without compromising ergonomics or agility in the daily workflow.
2. Technical explanation of the equipment
The BPP 30 HV acts as a mobile biological barrier interposed between the operator and the radioactive source. Its structure integrates a 30 mm lead shielding, designed to attenuate the annihilation gamma radiation (511 keV) emitted by high-energy PET radiopharmaceuticals such as fluorine-18 (F-18) or gallium-68 (Ga-68). The 80 mm thick high-density lead glass viewing window, inclined at 45°, provides comfortable, distortion-free visual control of the ongoing manipulation, maintaining over its entire surface a protection equivalent to that of the rest of the shielding. The main advantage of this shield is its pedal-operated hydraulic lifting system, which allows the height of the assembly to be adjusted smoothly and effortlessly, adapting the protection to the height of each professional and ensuring complete body coverage (head, trunk and limbs) both in a seated and standing position. Its stable base and wheels facilitate movement within the room and its strategic positioning in front of the injection or dose preparation station.
3. Technical Specifications
The reference specifications of the mobile protective shield BPP 30 HV, manufactured by Lemer Pax (France) and marketed by Cahnos under the code CAH-LPBPP30 HV, are detailed below:
| Parameter | Specification |
| Model | BPP 30 HV |
| Reference (SKU) | CAH-LPBPP30 HV |
| Factory reference | 00016732 |
| Manufacturer | Lemer Pax (France) |
| Main function | Mobile radiation-protected barrier for preparation and injection of PET radiopharmaceuticals |
| Radiation protection | 30 mm of lead |
| Viewing window | High-density lead glass, 80 mm thick (L 320 x H 200 mm) |
| Window inclination | 45° |
| Height adjustment | Pedal-operated hydraulic system |
| Overall dimensions | L 666 x D 739 x H 1447/1647 mm |
| Inclined height | From 1230 to 1430 mm |
| Weight | 255 kg |
| Energy range | High energy (PET radiopharmaceuticals: F-18, Ga-68) |
| Scope of use | Nuclear Medicine, radiopharmacy, preparation and injection rooms |
| Protection principle | ALARA |
Packaging data: L 1025 x D 725 x H 1800 mm; packaging weight 310 kg.
Comparison of available versions:
| Characteristic | BPP 30 HV | BPP 30 MRI |
| Overall dimensions | L 666 x D 739 x H 1447/1647 mm | L 580 x D 620 x H 1480 mm |
| Adjustable height | Yes (pedal hydraulic) | No |
| Inclined height | From 1230 to 1430 mm | 1230 mm |
| Weight | 255 kg | 195 kg |
| Special application | Standard | Antimagnetic, compatible with PET/MRI |
4. Equivalences and Cross-References
The CAH-LPBPP30 HV shield corresponds to the factory reference 00016732 (BPP 30 HV) from Lemer Pax, a leading European manufacturer in radiation protection. Its antimagnetic variant is the model BPP 30 MRI, designed for rooms with hybrid PET/MRI equipment (check availability). Within the Cahnos catalogue, it shares a family with the RadScreen Mobile Shielded Screen (CAH-PMB-20-A) for room barriers, with the TableShield Shielded Table Screen (CAH-EM-30-V60) for benchtop stations, with the HBI shielded inclined viewing window (CAH-LP00033337) for workbenches, and with the InjectShield (CAH-EI-30-RG) and InjectShield RM (CAH-ISR-AE) injection shields for dose administration. As complementary solutions for the radiation-protected workflow, it integrates with tungsten syringe shields from the same Lemer Pax family (Mediclic LME CAH-LP11453, Mediclic HE CAH-LP11653), vial shields, shielded transport trolleys (CAH-FSM-30-AE) and radioactive waste containers, covering from preparation to administration of the radiopharmaceutical.
5. Selection tips and variants of interest
To choose the optimal configuration, consider the energy spectrum and activity of the radioisotopes you handle: the BPP 30 HV, with 30 mm of lead and an 80 mm lead glass window, is the recommended option for high-energy PET radiopharmaceuticals. Always confirm the shielding thickness with your radiation protection service based on the area’s design dose calculation. Check the dimensions of doors, corridors and lifts before installation, taking into account the weight of the equipment (255 kg) and its packaging (310 kg), as well as the load capacity of the room. If you have hybrid PET/MRI equipment, consider the non-magnetic BPP 30 MRI version to avoid interference with the magnetic field. Combine this shield with syringe protectors, vial shields, injection shields, transport systems and shielded containers to complete a comprehensive radiation protection strategy. For equipping or tendering projects, request a customised quotation from our technical-commercial team, who will advise you on the most suitable configuration for your Nuclear Medicine service.