Description
Stainless steel suture Premisut HRT48 Heavy 7: permanent strength for high-demand surgery
The stainless steel suture Premisut in USP 7 gauge is the reference solution for closures that must withstand the greatest mechanical tension: sternal fixation after sternotomy, abdominal wall closure, tendon repair and load-bearing orthopaedic procedures. Its non-absorbable nature guarantees indefinite wound support, with the highest tensile strength of all available suture materials, maintaining tension strength throughout healing and permanently. Each box contains 12 sterile units, ready for use in the operating theatre.
How this suture works: why 316 steel makes the difference
The thread is an uncoated monofilament of surgical stainless steel 316, a high-purity alloy (chromium, nickel and molybdenum) that offers exceptional corrosion resistance in contact with biological fluids and minimal tissue reaction. Being inert and non-absorbable, the suture gradually encapsulates in the tissue, maintaining its tensile strength indefinitely: that is why it is the current standard in sternal fixation and the preferred option in orthopaedics.
The ½ circle (1/2 circular) needle with 48 mm trocar point in Heavy version (HRT48) has a cylindrical body and conical atraumatic penetration point, designed to pass through dense and fibrous tissues with a clean, controlled passage and minimal tissue damage. The grooved metal finish improves knot retention, a critical condition in tissues under sustained load. Configuration 5/7 – 4 threads of 45 cm.
Technical specifications
| Material | Stainless steel 316 (uncoated monofilament) |
| Structure | Monofilament |
| Needle type | ½ circle (1/2 circular) |
| Needle tip | Trocar (conical / taperpoint), cylindrical body |
| Needle size | 48 mm (HRT48 Heavy) |
| Gauge | USP 7 (metric equivalence EP 9) |
| Configuration | 5/7 – 4 threads |
| Thread length | 4 × 45 cm |
| Finish | Ribbed metal, uncoated |
| Colour | Metal |
| Absorption | Non-absorbable, gradual encapsulation |
| Sterilisation | Ethylene oxide (EO) |
| Use | Single-use, not re-sterilisable |
| Storage | Below 30 °C, protected from moisture and direct sunlight |
| Presentation | Box of 12 sterile units |
| Minimum order | 10 boxes |
| Manufacturer reference | P961HRT4807H.4 |
| SKU Cahnos | AMP961HRT4807H.4 |
Equivalences and cross-references
There is no official equivalence table validated by the manufacturer for this reference. The correspondences indicated below are functional comparisons verified against catalogues and official sources of the cited manufacturers, and must be confirmed with the technical department before use in tendering. The essential difference is the point geometry: this reference uses a conical trocar point needle (cylindrical body), while most sternal references on the market incorporate a cutting or sternum point.
| Manufacturer / Brand | Family / Model | Code / Reference | Equivalence level | Technical differences / Remarks |
| Ethicon (J&J MedTech) | Surgical Stainless Steel (Surgisteel) | M624G (USP 7, CPX needle 48 mm ½ circle, 4×45 cm) | Comparable at category level, not interchangeable 1:1 | Same USP 7 gauge (EP 9) and same presentation 4×45 cm, but CPX needle of 48 mm with reverse cutting point, different geometry from the conical trocar point of this reference. |
| Ethicon (J&J MedTech) | Surgical Stainless Steel (Surgisteel) | M653G (USP 5, CCS needle 48 mm ½ circle, 4×45 cm) | Comparable at category level, not interchangeable 1:1 | Format 4×45 cm with 48 mm needle, but lower USP 5 gauge and conventional sternal cutting point (CCS), not conical trocar. |
| B. Braun | Steelex Sternum Set | G0617795 (STE SET 7 (9) 4×45 cm HRS48 LP) | Comparable at category level, not interchangeable 1:1 | Same USP 7 gauge (EP 9) and 4×45 cm, but HRS48 needle with round body and sternum point, different geometry from the conical trocar point. |
| B. Braun | Steelex | G0617814 (STE SET 6 (8) 4×45 cm HRS48 LP) | Comparable at category level, not interchangeable 1:1 | Same format 4×45 cm, lower USP 6 gauge (EP 8) and different sternum point. |
| DemeTECH | DemeSTEEL Surgical Steel | SW4x110548B6P (USP 5, DV-40 needle 1/2 circle tapercut 48 mm, 4×45 cm) | Comparable at category level, not interchangeable 1:1 | Presentation 4×45 cm, but lower USP 5 gauge and tapercut needle (conical cutting), not pure trocar point. |
| Atramat | Stainless steel thread | G-W481050 / KW481050X4 (STEEL 5, needle ½ circle 48 mm round cutting point) | Comparable at category level, not interchangeable 1:1 | Lower USP 5 gauge and round cutting point, cutting geometry different from the conical trocar. |
| Lorca Marín | Monofilament steel suture | No publicly verified code | Comparable by category | Spanish manufacturer of monofilament steel sutures for abdominal, tendon and sternum containment; code not verifiable in public sources, confirm with the manufacturer. |
Selection tips and variants of interest
The USP 7 gauge with 48 mm HRT48 Heavy needle is especially indicated for sternal closure after sternotomy and cerclage of high-density tissues, where a controlled needle passage is combined with maximum load retention. In the same Premisut family with HRT48 trocar point (4×45 cm), USP 4 (AMP961HRT4804H.4), USP 5 (AMP961HRT4805H.4) and USP 6 (AMP961HRT4806H.4) gauges are available, in addition to the HRT40 needle variant of 40 mm in USP 1 (AMP961HRT4001H.4), to adjust strength according to tissue and surgeon preference. If a triangular reverse cutting point geometry is preferred, the Premisut Prime HS48 family offers USP 7 (AMP961HS4807.4) and lower gauges.
A 2=1=1=1 knotting technique is recommended and hold the needle between 1/3 and 1/2 of the distance from the connection to avoid deformation. Store below 30 °C, protected from humidity and direct sunlight; as it is sterile single-use material, check the integrity of the packaging and do not re-sterilise or reuse. For B2B conditions, volume orders or other gauges and lengths on request, contact the technical-commercial team of Cahnos.