Description
Steel suture Premisut Prime USP 2 – Precision and resistance for high-demand surgery
The steel suture Premisut Prime from Cahnos is the definitive solution for surgical procedures that demand superior mechanical resistance and permanent tissue fixation. Made of surgical-grade 316 stainless steel (uncoated monofilament), this non-absorbable suture offers exceptional tensile strength, minimal tissue reaction and gradual fibrous encapsulation, making it the reference choice for cardiac surgery, orthopaedics and repair of high-load structures.
Technical product explanation
The 316 stainless steel wire (type 316LVM, conforming to ASTM F138 standards for implants) is presented as a fluted monofilament in metal colour, uncoated. The ½ circle needle with reverse cutting triangular point of 48 mm is designed to penetrate dense and fibrous tissues, such as the sternum, fasciae and tendons, with controlled penetration and minimal tissue damage. The USP 2 gauge (equivalent to EP 5) provides a wire diameter of approximately 0.5–0.599 mm, offering an optimal balance between manageability and tensile strength for cerclage and approximation of tissues under high tension. The configuration of 4 wires of 45 cm allows multiple sterile units per box, optimising workflow in the operating theatre.
Technical specifications
| Characteristic | Value |
|---|---|
| Material | Stainless steel 316 / 316LVM (uncoated monofilament) |
| Needle type | ½ circle |
| Needle tip | Triangular reverse cutting (reverse cutting) |
| Needle length | 48 mm (HS48) |
| Gauge | USP 2 / EP 5 |
| Thread length | 4 x 45 cm |
| Finish | Fluted, metal colour, uncoated |
| Presentation | Box of 12 sterile units |
| Minimum order | 10 boxes |
| Sterilisation | Ethylene oxide (EO) |
| Use | Single-use, not re-sterilisable |
| Storage | Below 30 °C, protected from humidity and sunlight |
| Reference | AMP961HS4802.4 |
Equivalences and cross-references
Important note: There is no equivalence table validated by the manufacturer for this reference. The following comparisons are indicative and must be verified against the corresponding manufacturer’s technical data sheet before use in tendering.
| Manufacturer / Brand | Family / Model | Code / SKU | Equivalence level | Technical differences / Remarks |
|---|---|---|---|---|
| Trusteel (Conemed Healthcare) | Trusteel Sternotomy | TS 650 P4 | Comparable by category, not interchangeable 1:1 | Same USP 2 gauge and 45 cm length, ½ circle needle of 48 mm but TC point (taper cutting), not reverse cutting triangular. Material 316LVM steel. |
| DemeSTEEL (DemeTECH) | Surgical Steel Suture | SW3x110226B0P | Comparable by category, not interchangeable 1:1 | USP 2, ½ circle DSH needle with round body (round bodied), presentation 3×45 cm (three wires per envelope). It is not a cutting point. |
| Ethicon (J&J MedTech) | Surgical Stainless Steel | M652G | Comparable by category, not interchangeable 1:1 | ½ circle needle of 48 mm, but USP 4 gauge (not USP 2) and CCS point (conventional cutting sternum), not reverse cutting. |
| Ethicon (J&J MedTech) | Surgical Stainless Steel | M651G | Comparable by category, not interchangeable 1:1 | ½ circle needle 48 mm V-40 TAPERCUT, USP 4 gauge. Taper cutting point, not reverse triangular. |
| Ethicon (J&J MedTech) | Surgical Stainless Steel | M653G | Comparable by category, not interchangeable 1:1 | ½ circle needle 48 mm CCS, USP 5 gauge. Conventional sternal point, not reverse cutting. |
| Atramat | Stainless steel | KW481050X4 / G-W4810 | Comparable by category, not interchangeable 1:1 | KW-48 needle (½ circle 48 mm) with thick round cutting point, USP 5 gauge. It does not match in gauge or point geometry. |
Within the Cahnos Premisut catalogue itself, the closest references are:
- AMP961HS4002.4: same family and USP 2 gauge, but HS40 needle (40 mm) instead of HS48.
- AMP961HS4804.4: same HS48 needle, but USP 4 gauge.
Consult the Cahnos technical department before substituting this product in a tender or surgical protocol.
Selection tips and variants of interest
For sternal closure procedures after median sternotomy, this USP 2 configuration with HS48 needle is recommended for its balance between wire diameter and bone penetration capacity. If a larger gauge is required for extreme-load cerclage, consider the variants USP 4 (AMP961HS4804.4), USP 5 (AMP961HS4805.4) or USP 6/7. For approaches with less access or finer tissue, the alternative with HS40 needle (AMP961HS4002.4) may be more suitable. The cylindrical needle family with trocar point (HRT) is also available for soft tissue applications. Always verify needle compatibility with the needle holder and the knotting technique (square knots with additional throws) before the procedure.





Reviews
There are no reviews yet.