Description
1. Commercial Introduction
The SEDA PREMISUT PRIME Suture is the benchmark of the premium range of non-absorbable sutures from Cahnos for the professional seeking a natural-origin thread that is manageable and offers predictable clinical performance. This configuration combines a 100% natural braided silk multifilament, coated with wax and silicone, in high-visibility black, USP 6/0 gauge, with a ⅜-circle needle with a 16 mm reverse cutting triangular point (DS16 Prime profile) and a 45 cm strand.
Sterile, ready-to-use product, supplied in a box of 12 units in individual sachets with full batch traceability. Ideal for hospital replenishment, purchasing centres, tenders and volume contracts seeking a permanent high-performance thread, Prime-quality sharpening consistency batch after batch and excellent value for money.
2. Technical explanation of the material and procedure
Surgical silk is a natural protein fibre (fibroin from the cocoon of Bombyx mori) presented in a braided multifilament construction and coated with a mixture of wax and silicone. This coating reduces capillarity and bacterial drag, facilitates the sliding of the thread through tissue and guarantees a firm, secure knot with the recommended tying technique 2 = 1 = 1 = 1, one of the most valued qualities of surgical silk. PRIME quality adds maximum sharpening control, a non-grooved surface and batch-to-batch consistency.
Being a non-absorbable material, the thread does not degrade by hydrolysis: the body gradually encapsulates it with connective tissue and maintains tensile strength for more than three months, comfortably covering the critical healing phase. The DS16 16 mm needle features a ⅜-circle curvature with a body and triangular reverse cutting point (reverse cutting): the cutting edge is located on the outer face of the curvature, so it passes through skin and firm, non-distensible tissues without enlarging the puncture bed, minimising trauma and improving the aesthetic result. The USP 6/0 gauge (metric EP 0.7) is ideal for very delicate planes (face, eyelids, mucous membranes, microsurgery) and the black colour ensures optimal contrast on the surgical field. Sterilisation by ethylene oxide (EO); single-use product, not re-sterilisable.
3. Technical Specifications
3.1. General characteristics
| Parameter | Specification |
|---|---|
| Factory reference | P541DS1660 (PRIME range) |
| Reference Cahnos (SKU) | AMP541DS1660 |
| Brand / quality | PREMISUT PRIME (premium range) |
| Thread material | 100% natural silk (fibroin from Bombyx mori), braided multifilament |
| Thread structure | Braided, non-grooved finish (Prime) |
| Coating | Wax and silicone (anti-capillary, low tissue drag) |
| Absorption type | Non-absorbable; gradual encapsulation, wound support for more than 3 months |
| USP gauge / size | USP 6/0 (metric EP 0.7), conforming to USP Pharmacopoeia and European Pharmacopoeia |
| Approximate thread diameter | 0.070 – 0.099 mm (USP Pharmacopoeia, non-absorbable suture) |
| Thread length | 45 cm (single strand, free end) |
| Thread colour | Black identifier (high visibility in surgical field) |
| Needle shape | ⅜ circle (3/8 circular), body and point |
| Tip type | Reverse cutting triangular (reverse cutting) |
| Needle size | 16 mm (DS16 Prime profile), 1 needle per thread |
| Swaged | 1 swaged needle / 1 thread per unit |
| Recommended knotting technique | 2 = 1 = 1 = 1 |
| Sterilisation | Ethylene oxide (EO); sterile, single-use, non-resterilisable |
| Indications | Approximation of soft tissues, ligatures, ophthalmology and skin surgery |
| Commercial presentation | Box of 12 units (sterile individual sachets); minimum order of 30 boxes; batch traceability |
| Regulatory standard | Conforms to USP/EP Pharmacopoeia for non-absorbable sutures; CE marking (MDR) |
3.2. Gauge equivalence according to USP/EP Pharmacopeia (non-absorbable suture)
| USP size | Metric measurement (EP) | Approximate thread diameter |
|---|---|---|
| 6/0 (this product) | 0.7 | 0.070 – 0.099 mm |
| 5/0 | 1 | 0.10 – 0.149 mm |
| 4/0 | 1.5 | 0.15 – 0.199 mm |
| 3/0 | 2 | 0.20 – 0.249 mm |
The strand diameter complies with the official USP Pharmacopoeia ranges for non-absorbable sutures, without exceeding their limits.
3.3. Reading the factory reference
The reference P541DS1660 is decoded as follows: P = PRIME quality; 541 = black silk thread, 45 cm (542 = 75 cm, 543 = 90 cm); DS16 = ⅜-circle needle with 16 mm reverse cutting triangular point; 60 = USP 6/0 gauge (50 = 5/0, 40 = 4/0, 30 = 3/0). Cahnos markets the official reference without altering characters: no digit may be added, removed or reordered when ordering or tendering.
4. Equivalences and Cross-References
The reference P541DS1660 corresponds to the official nomenclature of the PREMISUT PRIME range (DS16 profile: ⅜-circle needle with 16 mm reverse cutting triangular point, USP 6/0 gauge, 45 cm black non-grooved thread and single-needle configuration). Black braided coated non-absorbable silk is one of the most standardised natural suture families on the market. The references from other manufacturers detailed below share material, USP 6/0 gauge, black colour, 45 cm length, ⅜-circle curvature and reverse cutting point family, and have been checked against the manufacturer’s official catalogue; as they are another brand, they do not constitute an exact reference equivalence (reserved for the same manufacturer) and must be validated against the IFU and CE/MDR classification before any substitution.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
|---|---|---|---|---|
| B. Braun (Aesculap) | Silkam® Black – natural braided and coated multifilament silk, non-absorbable | C0762113 – SILKAM BLACK 6/0 (0.7) 45 CM DS16 (confirmed in official catalogue B. Braun) | Comparable by category (not interchangeable 1:1) | They match in material (coated braided silk), USP 6/0 gauge (EP 0.7), black colour, 45 cm length, ⅜-circle curvature, reverse cutting point family, DS16 needle size (16 mm) and configuration of 1 needle per thread; it is the closest technical match found. They differ in brand, exact coating composition and sterilisation system; validate IFU and CE/MDR before substituting. |
| Ethicon (Johnson & Johnson MedTech) | MERSILK® – non-absorbable black braided silk, 6-0, 45 cm, PC-3 PRIME needle ⅜ circle of 16 mm reverse cutting | W529H (confirmed in Ethicon catalogue and authorised distribution) | Comparable by category (not interchangeable 1:1) | They match in material (black coated braided silk), 6/0 gauge, 45 cm length, ⅜ radius and 16 mm needle with reverse cutting point. They differ in the coating (special wax mixture versus wax and silicone) and the exact needle profile (PC-3 PRIME versus DS16 Prime). |
| DemeTECH | DemeSILK™ – black braided silk, 6/0, 45 cm, 16 mm needle of ⅜ circle reverse cutting | SK166016F4P (confirmed in official DemeTECH catalogue and authorised distribution) | Comparable by category (not interchangeable 1:1) | Same material (black braided silk), USP 6/0 gauge, 45 cm length, ⅜ radius and 16 mm reverse cutting needle. They differ in the exact coating, needle profile and sterilisation system. |
There is no equivalence table validated by the manufacturer that cross-references this specific configuration (black braided silk, DS16 16 mm needle in ⅜ circle with reverse cutting point, USP 6/0 gauge and 45 cm strand, PRIME quality) with references from other manufacturers; consult the technical department of Cahnos before using in tenders or direct substitution. Other homologous families of black braided silk present on the European market — Medtronic Sofsilk™, Assut Surgisilk™, SMI Silk Braided, Corza Medical LOOK™ Silk, Serag-Wiessner, Unilene and Laboratorio Aragó — must be reviewed property by property (material, coating, gauge, curvature, point family and size, strand length, configuration, colour and CE/MDR regulatory classification) before any formal substitution. The brands cited belong to their respective manufacturers and are mentioned solely as comparative reference.
5. Selection tips and variants of interest
Tissue to be sutured: the USP 6/0 gauge (metric EP 0.7) is the precision choice for very delicate planes — fine skin, facial contour, eyelids, mucous membranes, ophthalmology and microsurgery — where the fine diameter minimises tissue reaction. The DS16 16 mm needle with reverse cutting point in ⅜ circle passes through firm, non-distensible tissues without tearing the puncture bed and improves scar aesthetics, being the preferred operating theatre format when a greater needle reach than the DS12 microsurgery needle is required.
Variants of interest within the Cahnos catalogue (same PREMISUT range of black silk):
| Variant / Reference | Description |
|---|---|
| AM541DS1660 (541DS1660) | Standard SILK DS16 – 6/0 black – 45 cm (same geometry, standard range, technically interchangeable) |
| AMP542DS1660 (P542DS1660) | SILK PRIME DS16 – 6/0 black – 75 cm (same needle and gauge, longer thread for continuous sutures) |
| AM542DS1660 (542DS1660) | Standard SILK DS16 – 6/0 black – 75 cm |
| AM542DS1650 (542DS1650) | Standard SILK DS16 – 5/0 black – 75 cm (same needle, thicker gauge) |
| AM542DS1960 (542DS1960) | Standard SILK DS19 – 6/0 black – 75 cm (greater needle reach, same gauge) |
| AMP542DS2460 (P542DS2460) | SILK PRIME DS24 – 6/0 black – 75 cm (24 mm needle for deeper planes) |
| AMP541XDS1160 (P541XDS1160) | SILK PRIME XDS 11 mm – 6/0 black – 45 cm (precision reverse cutting with square body) |
Sterility and storage: sterile product by ethylene oxide and single-use; check the integrity of the blister and the expiry date before each procedure, keep the reference P541DS1660 together with the batch number for traceability in the operating theatre and store below 30 °C, away from moisture and direct sunlight. For special B2B conditions by volume, hospital supply agreements or validation of equivalents from other commercial houses, contact the technical-commercial team of Cahnos.





Reviews