Description
1. Product Presentation
We offer you the braided silk suture from the PREMISUT PRIME range, reference P542DS6001 (SKU AMP542DS6001), a professional solution for B2B supply to operating theatres, purchasing centres, general and specialist surgery services, as well as ophthalmology and skin surgery units.
This presentation incorporates a ⅜ circle needle with reverse cutting triangular point (model DS60) of 60 mm and a black braided thread of 75 cm in USP 1 gauge, one of the most demanded configurations for suturing firm tissues and planes under some tension. Predictable behaviour, high tensile strength and special conditions for hospital supply and volume contracts.
2. Technical explanation of the material and procedure
Silk is a non-absorbable suture of natural origin, formed by braided fibroin filaments around a twisted core (multifilament structure). This construction provides excellent tensile strength and a very secure knot ratio, classic characteristics of surgical silk, along with gradual encapsulation that maintains mechanical wound support for more than three months. The wax and silicone coating facilitates thread sliding through tissue, reduces the saw effect and protects the suture area during knotting.
The ⅜ circle needle with reverse cutting triangular point of 60 mm is designed to penetrate firm tissues such as skin and mucous membranes, making a clean and controlled cut, with the cutting edge oriented towards the outside of the curve to minimise tearing. The USP 1 gauge (metric EP 4) provides high tensile strength for areas under tension. The black colour of the thread ensures optimal contrast on the surgical field. Sterilisation by ethylene oxide ensures sterile delivery, ready for immediate use; it is a single-use product and does not allow re-sterilisation.
3. Technical Specifications
| Parameter | Specification |
|---|---|
| Reference (SKU Cahnos) | AMP542DS6001 |
| Manufacturer reference | P542DS6001 |
| Brand / quality | PREMISUT PRIME |
| Material | 100% natural silk (fibroin), multifilament braided over a twisted core |
| Coating | Wax and silicone |
| Thread structure | Braided (multifilament) |
| Suture type | Non-absorbable, with gradual encapsulation and high tensile strength |
| USP gauge / size | USP 1 (metric EP 4) |
| Thread diameter | 0.40 – 0.499 mm |
| Thread length | 75 cm |
| Thread colour | Black (high visibility in surgical field) |
| Needle shape | 3/8 circle |
| Tip type | Triangular reverse cutting (Reverse Cutting) |
| Needle size | 60 mm (model DS60) |
| Swaged | 1 needle per suture |
| Wound support | More than three months |
| Sterilisation | Ethylene oxide (EO); sterile, single-use, non-re-sterilisable |
| Indications | Approximation of soft tissues, ligatures, ophthalmology and skin surgery |
| Presentation | Box of 12 units; minimum order 30 boxes |
Gauge equivalence (non-absorbable suture, according to USP Pharmacopeia):
| USP size | Metric measurement (EP) | Approximate diameter |
|---|---|---|
| 1 | 4 | 0.40 – 0.499 mm |
4. Equivalences and Cross-References
Black braided non-absorbable silk is one of the permanent suture families with the greatest clinical tradition. There is no official equivalence table validated by the manufacturer that cross-references this specific configuration (DS60 reverse cutting 3/8 circle needle of 60 mm, USP 1 gauge, black, 75 cm) with references from other brands; therefore, matches should be treated as functional comparisons and not as 1:1 interchangeable without technical validation. The cited references have been checked against official catalogue, regulatory databases (GUDID) or authorised distributors and are indicated with their differences.
| Manufacturer / Brand | Family / Model | Code / Reference | Equivalence level | Technical differences / Remarks |
|---|---|---|---|---|
| B. Braun | Silkam® black – DS60 needle (3/8 circle, reverse cutting) | C0764892 (Silkam Black 1 [EP 4], 75 cm, DS60) | Comparable by category (not interchangeable 1:1) | Technically almost identical profile: non-absorbable braided and coated silk, USP 1 gauge (EP 4), black colour, 75 cm thread and DS60 needle of 60 mm in 3/8 circle with reverse cutting point. Code and attributes confirmed in the official catalogue of B. Braun and in GUDID (GTIN 04038653835218; status out of commercial distribution in the USA, verify availability in European market). Validate commercial presentation and sterilisation before substituting. |
| Ethicon (Johnson & Johnson) | MERSILK® (black braided silk) | NW5062 (USP 1, black, 76 cm, 3/8 circle needle of 60 mm) | Comparable by category (not interchangeable 1:1) | They match in material (braided silk), USP 1 gauge, black colour and 60 mm needle in 3/8 circle. The thread length is 76 cm (vs 75 cm) and the point geometry is described as cutting/reverse cutting depending on market; confirm the exact point and presentation (box of 12 units) in the official data sheet before substituting. Code consistently located in several authorised distributors; official EMEA catalogue reference for this configuration pending confirmation with the manufacturer. |
There is no equivalence table validated by the manufacturer for this exact configuration (DS60 reverse cutting 3/8 circle needle of 60 mm, USP 1, black, 75 cm); consult with the technical department before using in a tender. Other homologous families of black braided non-absorbable silk, whose specific codes are pending verification from official source, are: Ethicon MERSILK with KS needle (straight, not applicable to this curved configuration), Aragó Silk and Serag-Wiessner Silk; verify in each case the gauge, size and geometry of needle, colour and thread presentation. It is warned not to confuse the reference P1691H from MERSILK (FSLX needle of 36 mm, not comparable in length to the DS60). Before any formal substitution, check in the alternative manufacturer’s technical data sheet the exact gauge, thread length, needle geometry and size, colour, surface treatment and regulatory classification (CE/MDR). The cited brands belong to their respective manufacturers and are mentioned only as equivalence reference.
5. Selection tips and variants of interest
Assess the wound support time required by the tissue and the gauge according to the anatomical area: USP 1 gauge (metric 4) is a high thickness, indicated for soft tissues with considerable tension, vessel ligatures and planes requiring greater tensile strength; for fine skin and precision surgery, lower gauges (USP 3/0 and 2/0) are more versatile. Always check the needle geometry: the 3/8 circle reverse cutting needle (DS series) is ideal for deep sutures and firm tissues, while straight needle formats (GS series) are oriented to manual suture for direct access and ligatures.
Variants of interest within the Cahnos catalogue:
- AM542DS6001: same configuration in standard quality (PREMISUT silk DS60, USP 1, black, 75 cm).
- AMP542DS6001.2: PREMISUT PRIME silk, DS60 needle, USP 1, black, presentation of 2 threads of 75 cm (double thread per unit).
- AMP542DS6010: PREMISUT PRIME silk, DS60 needle, USP 0 gauge, black, 75 cm.
- AMP542DS4001 / AMP542DS3001: same PREMISUT PRIME range USP 1 with 3/8 circle reverse cutting needle of 40 mm and 30 mm (for more superficial accesses).
- AMP542GS6001: PREMISUT PRIME USP 1 silk with straight GS60 needle, 60 mm, and conventional cutting edge (for direct manual suturing).
As this is a sterile, single-use product, check the integrity of the packaging before each procedure, respect the expiry date and store it in a cool, dry place, protected from sunlight. For special B2B conditions by volume, hospital supply agreements or equivalents from other commercial houses, contact the technical-commercial team at Cahnos.





Reviews