We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice
Sale!

Non-Absorbable Silk Suture PREMISUT PRIME – ⅜ Circle Needle Reverse Cutting Triangular Point 16 mm (DS16) – USP 6/0 (EP 0.7) – Black Braided Non-Grooved Thread 75 cm – Box of 12 units (Ref. P542DS1660 · SKU AMP542DS1660)

Original price was: 24,10 €.Current price is: 17,10 €.

Non-absorbable suture of 100 % natural braided silk PREMISUT PRIME (Ref. P542DS1660 · SKU AMP542DS1660): USP 6/0 gauge (metric EP 0.7), black thread of 75 cm with non-grooved Prime finish, mounted on a ⅜ circle needle with reverse cutting triangular point of 16 mm (DS16 profile). Coated with wax and silicone: smooth passage through tissue, low capillarity and very secure knot (2 = 1 = 1 = 1 technique), with wound support exceeding three months due to gradual encapsulation. Sterilised by ethylene oxide, single-use. Ideal for approximation of soft tissues, ligatures, ophthalmology and skin surgery. Presentation in a box of 12 units in individual sachets with batch traceability.

Se fabrica bajo pedido: el fabricante exige un mínimo de 30 unidades por referencia.

International shipping. Import duties and taxes are payable by the recipient.

Reference
AMP542DS1660

Description

1. Commercial Introduction

The Silk Suture PREMISUT PRIME with a ⅜ circle needle, 16 mm reverse cutting triangular point (DS16 profile), USP 6/0 gauge (metric EP 0.7) and 75 cm black braided thread (Manufacturer ref. P542DS1660 · SKU AMP542DS1660) is the choice of the professional seeking a non-absorbable thread of natural origin with exceptional handling, firm feel and extremely reliable knot security.

It belongs to the Prime range: non-grooved thread finish with a more uniform surface and reinforced batch traceability, indicated for operating theatres, ophthalmology clinics, skin surgery and microsurgery of delicate tissues, as well as for purchasing centres, tenders and B2B hospital supply agreements that require predictable clinical performance and continuous replenishment.

2. Technical explanation of the material and procedure

Surgical silk is a natural protein fibre (fibroin, from the cocoon of Bombyx mori) presented in a braided multifilament construction and coated with a mixture of wax and silicone. This coating reduces capillarity and bacterial wicking, favours the sliding of the thread through the tissue and guarantees a firm and secure knot with the recommended knotting technique 2 = 1 = 1 = 1, one of the most valued qualities of surgical silk.

Being a non-absorbable material, the thread does not degrade by hydrolysis: it is gradually encapsulated by connective tissue and maintains tensile strength for more than three months, comfortably covering the critical healing phase. The DS16 16 mm needle features a ⅜ circle curvature with a reverse cutting triangular body and point (reverse cutting): the cutting edge is located on the outer face of the curvature, so it passes through skin and firm, non-distensible tissues without enlarging the puncture bed, minimising trauma and improving the aesthetic result. The USP 6/0 (metric EP 0.7) gauge is ideal for very delicate planes (face, eyelids, mucous membranes, microsurgery) and the black colour guarantees optimal contrast on the surgical field. Sterilisation by ethylene oxide (EO); single-use product, not re-sterilisable.

3. Technical Specifications

3.1. General characteristics

Parameter Specification
Brand / Range PREMISUT PRIME (premium range, 1 needle / 1 thread per unit)
Factory reference P542DS1660
SKU Cahnos AMP542DS1660
Thread material 100% natural silk (fibroin from Bombyx mori), braided multifilament
Thread structure Braided, Prime non-grooved finish, black colour
Coating Wax and silicone
Absorption type Non-absorbable; gradual encapsulation, wound support for more than 3 months
USP gauge / size USP 6/0 (metric EP 0.7); conforming to USP Pharmacopoeia and European Pharmacopoeia
Approximate thread diameter 0.07 – 0.099 mm (USP Pharmacopeia, non-absorbable suture)
Thread length 75 cm (1 thread per unit)
Thread colour Black (high visibility in surgical field)
Needle shape ⅜ circle (3/8), body and point
Tip type Reverse cutting triangular (reverse cutting), grooved
Needle size 16 mm (DS16 model)
Swaged 1 swaged needle per thread
Recommended knotting technique 2 = 1 = 1 = 1
Sterilisation Ethylene oxide (EO); sterile, single-use, non-resterilisable
Indications Approximation of soft tissues, ligatures, ophthalmology and skin surgery
Commercial presentation Box of 12 units (sterile individual sachets); batch traceability

3.2. Gauge equivalence according to USP/EP Pharmacopeia (non-absorbable suture)

USP size Metric measurement (EP) Approximate thread diameter
6/0 (this product) 0.7 0.07 – 0.099 mm
5/0 1 0.10 – 0.149 mm
4/0 1.5 0.15 – 0.199 mm
3/0 2 0.20 – 0.249 mm
2/0 3 0.30 – 0.339 mm

3.3. PREMISUT family in silk, DS16 needle (⅜ circle, reverse cutting, 16 mm, black thread 75 cm)

USP size Thread Factory reference Code Cahnos
6/0 (this product, Prime) 1 × 75 cm (black) P542DS1660 AMP542DS1660
6/0 (standard range) 1 × 75 cm (black) 542DS1660 AM542DS1660
5/0 1 × 75 cm (black) 542DS1650 AM542DS1650
4/0 1 × 75 cm (black) 542DS1640 AM542DS1640
3/0 1 × 75 cm (black) 542DS1630 AM542DS1630
2/0 1 × 75 cm (black) 542DS1620 AM542DS1620

4. Equivalences and Cross-References

The reference P542DS1660 corresponds to the official nomenclature of the PREMISUT PRIME range (DS16 profile: ⅜ circle needle with 16 mm reverse cutting triangular point, USP 6/0 gauge, 75 cm black thread and single-strand configuration) and Cahnos markets it without altering characters: no digit may be added, removed or reordered when ordering or tendering. Black braided coated non-absorbable silk is one of the most standardised natural suture families on the market. The match from another house detailed below has been checked against the official catalogue of the cited manufacturer; as it is another brand, it does not constitute an exact reference equivalence (reserved for the same manufacturer) and must be validated against the IFU before any substitution.

Manufacturer / Brand Family / Model Reference code / SKU Equivalence level Technical differences / Remarks
B. Braun (Aesculap) Silkam® Black – braided coated multifilament silk, non-absorbable C0764060 – SILKAM BLACK 6/0 (0.7) 75 CM DS16 Comparable by category (not interchangeable 1:1) They match in material (coated braided silk), USP 6/0 gauge (EP 0.7), black colour, ⅜ circle curvature, reverse cutting triangular point family, DS16 needle size (16 mm), 1 needle per thread configuration and 75 cm thread length; it is the closest technical match located. Code and attributes confirmed in the official B. Braun catalogue. They differ in brand, exact coating composition and sterilisation (gamma radiation versus ethylene oxide); validate IFU and CE/MDR classification before substituting.

There is no equivalence table validated by the manufacturer that cross-references this specific configuration (black braided silk, DS16 16 mm needle in ⅜ circle with reverse cutting point, USP 6/0 gauge and 75 cm thread) with references from other commercial houses; consult the technical department of Cahnos before using in a tender. Other homologous families of black braided silk present on the European market — Ethicon MERSILK® / PERMA-HAND™ Silk, Medtronic Sofsilk™, DemeTECH DemeSILK™, SMI Silk, Assut Surgisilk™, Unilene SEDA NEGRA TRENZADA and Serag-Wiessner — must be reviewed property by property (material, gauge, curvature and needle size, point geometry, number and length of strands, colour, coating and CE/MDR regulatory classification) before any formal substitution.

5. Selection tips and variants of interest

The USP 6/0 (metric EP 0.7) gauge is a very fine thread, indicated for minimal trauma approximations: facial cutaneous plane, eyelids, mucous membranes, microsurgery and precision sutures in ophthalmology; the 16 mm reverse cutting needle passes through firm tissues without tearing the puncture bed and improves the aesthetic result in reduced fields. The Prime non-grooved finish offers a more uniform surface and reinforced batch traceability, ideal for continuous replenishment in the operating theatre.

Variants of interest within the Cahnos catalogue, same PREMISUT range of black silk with DS16 16 mm needle and 75 cm thread:

  • AM542DS1660 (ref. 542DS1660): same profile in standard grooved range; technically interchangeable.
  • AM542DS1650 (ref. 542DS1650): USP 5/0 gauge, 75 cm black thread.
  • AM542DS1640 (ref. 542DS1640): USP 4/0 gauge, 75 cm black thread (fine and aesthetic surgery).
  • AM542DS1630 (ref. 542DS1630): USP 3/0 gauge, 75 cm black thread.
  • AM542DS1620 (ref. 542DS1620): USP 2/0 gauge, 75 cm black thread (moderate tension).
  • AM541DS1660 (ref. 541DS1660): same DS16 configuration, USP 6/0, with 45 cm thread.

If you require a longer needle reach, the same silk family offers the DS19 profile of 19 mm in USP 6/0 and 75 cm (AM542DS1960) and the DS24 Prime profile of 24 mm in USP 6/0 (AMP542DS2460). As this is a sterile single-use product, check the integrity of the blister and the expiry date before each procedure, keep the reference P542DS1660 together with the batch number for traceability in the operating theatre and store below 30 °C, away from moisture and direct sunlight. For special B2B conditions by volume, hospital supply agreements or validation of equivalents from other commercial houses, contact the technical-commercial team of Cahnos.

Additional information

Brand / Range

PREMISUT PRIME (premium range)

Material

100% natural silk (fibroin from Bombyx mori), braided multifilament

Thread structure

Braided, Prime non-grooved finish, black colour

Coating

Wax and silicone

Absorption type

Non-absorbable; gradual encapsulation, wound support for more than 3 months

USP size

USP 6/0 (metric EP 0.7)

Metric gauge (EP)

0.7

Thread diameter

0.07 – 0.099 mm (USP Pharmacopeia)

Needle shape

⅜ circle (3/8), body and point

Tip type

Reverse cutting triangular (reverse cutting)

Needle size

16 mm (DS16 model)

Swaged

1 swaged needle per thread

Knotting technique

2 = 1 = 1 = 1

Sterilisation

Ethylene oxide (EO); single-use, not re-sterilisable

Indications

Approximation of soft tissues, ligatures, ophthalmology and skin surgery

Presentation

Box of 12 units (individual sterile sachets)

Regulatory standard

Conforms to USP and European Pharmacopoeia

Manufacturer reference

P542DS1660

Medida de aguja

DS 16

Usp

6/0

Color

Black

Medida de hilo

75 cm

Tipo de aguja

Reverse cutting

Forma de aguja

3/8 circle

Calidad sutura

Prime

Reviews

There are no reviews yet.

Be the first to review “Non-Absorbable Silk Suture PREMISUT PRIME – ⅜ Circle Needle Reverse Cutting Triangular Point 16 mm (DS16) – USP 6/0 (EP 0.7) – Black Braided Non-Grooved Thread 75 cm – Box of 12 units (Ref. P542DS1660 · SKU AMP542DS1660)”

Your email address will not be published. Required fields are marked *