Description
1. Product Presentation
We offer you the braided silk suture from the PREMISUT PRIME range, reference P542DS6010 (SKU AMP542DS6010), a professional solution for B2B procurement in operating theatres, purchasing centres, general and specialist surgery departments, as well as ophthalmology units, skin surgery and microsurgery.
This presentation includes a ⅜ circle needle with a triangular reverse-cutting point (model DS60) of 60 mm and a black braided thread of 75 cm in USP 0 gauge, one of the most requested configurations for suturing soft tissues with moderate tension. Predictable behaviour, high tensile strength, high knot security and special conditions for hospital supply and volume contracts.
2. Technical explanation of the material and procedure
Silk is a non-absorbable suture of natural origin, formed by filaments of fibroin (protein from the cocoon of Bombyx mori) braided over a twisted core (multifilament structure). This construction provides excellent tensile strength and a very secure knot ratio (recommended tying technique 2 = 1 = 1 = 1), classic characteristics of surgical silk, as well as gradual encapsulation that maintains mechanical wound support for more than three months.
The wax and silicone coating reduces the capillarity of the thread, favours sliding through the tissue and minimises the sawing effect during passage and knotting. The ⅜ circle needle with triangular reverse-cutting point (reverse cutting) of 60 mm is designed to penetrate firm tissues such as skin and mucous membranes, making a clean, controlled cut, with the cutting edge facing outward of the curve to minimise tearing; its large reach makes it ideal for deep planes and wide fields. The black colour of the thread ensures optimal contrast on the surgical field.
3. Technical Specifications
| Parameter | Specification |
|---|---|
| Reference (SKU Cahnos) | AMP542DS6010 |
| Manufacturer reference | P542DS6010 |
| Brand / quality | PREMISUT PRIME |
| Material | 100% natural silk (fibroin), multifilament braided over a twisted core |
| Coating | Wax and silicone |
| Suture type | Non-absorbable, with gradual encapsulation and high tensile strength |
| USP gauge / size | USP 0 (metric EP 3.5) |
| Thread diameter | 0.35 – 0.399 mm |
| Thread length | 75 cm |
| Thread colour | Black (high visibility in surgical field) |
| Needle shape | ⅜ circle (3/8) |
| Tip type | Triangular reverse cutting (Reverse Cutting), triangular body and point, fluted |
| Needle size | 60 mm (model DS60) |
| Swaged | 1 needle per suture |
| Wound support | More than three months |
| Sterilisation | Ethylene oxide (EO); sterile, single-use, non-re-sterilisable |
| Indications | Approximation of soft tissues, ligatures, ophthalmology and skin surgery |
| Presentation | Box of 12 units; minimum order 30 boxes |
Gauge equivalence (non-absorbable suture, according to USP Pharmacopeia):
| USP size | Metric measurement (EP) | Approximate diameter |
|---|---|---|
| 0 | 3.5 | 0.35 – 0.399 mm |
4. Equivalences and Cross-References
Non-absorbable black braided silk is one of the permanent suture families with the greatest clinical tradition. There is no official equivalence table validated by the manufacturer that cross-references this specific configuration (⅜ circle reverse-cutting needle DS60 of 60 mm, USP 0 gauge, black, 75 cm) with references from other houses; therefore, the following matches should be treated as functional comparisons at category level and not as 1:1 interchangeable without technical validation. The cited references have been checked against the manufacturer’s official catalogue, GUDID database or authorised distribution, expressly indicating the differing field.
| Manufacturer / Brand | Family / Model | Code / Reference | Equivalence level | Technical differences / Remarks |
|---|---|---|---|---|
| B. Braun (Aesculap) | Silkam® – non-absorbable black waxed braided silk | C0764892 – Silkam Black 1 (EP 4), 75 cm, DS60 needle | Comparable by category (not interchangeable 1:1) | They match in material (braided silk coated with wax/silicone), black colour, thread length of 75 cm and the same DS60 needle of 60 mm in ⅜ circle with reverse-cutting point. Code and attributes confirmed in B. Braun official catalogue and in GUDID (GTIN 04038653835218). The gauge differs: USP 1 (EP 4) compared to USP 0 (EP 3.5) of the analysed reference; larger thread diameter, therefore not interchangeable 1:1. |
| B. Braun (Aesculap) | Silkam® – non-absorbable black waxed braided silk | C0762679 – Silkam Black 0 (EP 3.5), 75 cm, GS60 needle | Comparable by category (not interchangeable 1:1) | They match in material (braided silk), USP 0 gauge (metric 3.5), black colour and length of 75 cm. Code confirmed in B. Braun official catalogue. The needle differs: straight GS60 of 60 mm compared to the curved ⅜ circle DS60 with reverse-cutting point of this reference, therefore the suturing technique and depth penetration vary. |
| Ethicon (Johnson & Johnson) | MERSILK® – black non-absorbable braided silk | NW5037P – Mersilk USP 0, black, 76 cm, ⅜ circle reverse-cutting needle of 45 mm | Comparable by category (not interchangeable 1:1) | They match in material (waxed braided silk), USP 0 gauge, black colour, point geometry (⅜ circle, reverse cutting) and practically the entire length (76 cm vs 75 cm). Code consistently found in authorised Ethicon distributors. The needle size differs: 45 mm compared to 60 mm (smaller reach), which prevents 1:1 replacement in deep planes. |
| Ethicon (Johnson & Johnson) | MERSILK® / PERMA-HAND™ Silk – non-absorbable black braided silk | W562H – Mersilk/PERMA-HAND USP 1 (EP 4), black, 75 cm, LR-60 needle of 60 mm in ⅜ circle cutting | Comparable by category (not interchangeable 1:1) | They match in material (waxed braided silk), black colour, length of 75 cm and needle reach of 60 mm in ⅜ circle. Code found in authorised Ethicon distribution. The gauge (USP 1 vs USP 0) and point geometry (conventional cutting vs reverse cutting) differ, therefore it does not cover the exact combination of this reference. |
There is no equivalence table validated by the manufacturer for this exact configuration (⅜ circle DS60 reverse-cutting needle of 60 mm, USP 0, black, 75 cm); consult with the technical department before use in tenders. Other homologous families of non-absorbable black braided silk, whose specific codes are pending verification in official sources for the combination USP 0 + curved needle of 60 mm, are: Ethicon MERSILK with 60 mm needle in USP 0 gauge (not located in primary sources), Laboratorio Aragó Seda and Serag-Wiessner Seda; verify in each case gauge, needle size and geometry, colour, coating and thread presentation. Before any formal substitution, check the exact gauge, thread length, needle geometry and size, colour, surface treatment and regulatory classification (CE/MDR) on the alternative manufacturer’s technical data sheet. The mentioned brands belong to their respective manufacturers and are mentioned only as equivalence reference.
5. Selection tips and variants of interest
Assess the wound support time required by the tissue and the gauge according to the anatomical area: USP 0 (metric 3.5) is a medium-high thickness, indicated for soft tissues under moderate-to-high tension, vessel ligation and planes requiring good tensile strength; for fine skin and precision surgery, the smaller gauges (USP 3/0 and 2/0) are more versatile. Always check the needle geometry: the ⅜ circle needle with reverse cutting edge (DS series) is ideal for deep sutures and firm tissues, while straight needle formats (GS series) are intended for direct-access manual suturing and ligatures.
Variants of interest within the Cahnos catalogue:
- AMP542DS6010.2: PREMISUT PRIME silk, DS60 needle, USP 0, black, presentation of 2 threads of 75 cm per unit (double strand).
- AM542DS6010: same configuration in standard quality (PREMISUT DS60 silk, USP 0, black, 75 cm).
- AMP542DS6001: PREMISUT PRIME silk, DS60 needle, USP 1 gauge, black, 75 cm (greater thickness and support).
- AMP542DS6020: PREMISUT PRIME silk, DS60 needle, USP 2/0 gauge, black, 75 cm (finer gauge).
- AMP542DS3010: same PREMISUT PRIME silk with DS30 needle of 30 mm, USP 0, black, 75 cm (smaller fields).
- AMP542GS6010: PREMISUT PRIME silk with straight GS60 needle of 60 mm and conventional cutting edge (direct manual suturing).
- AMP642DS6010: PREMISUT Prime monofilament nylon with the same DS60 needle of 60 mm and USP 0 gauge, to alternate material according to surgeon preference.
As this is a sterile single-use product, check the integrity of the packaging before each procedure, respect the expiry date and store it in a cool, dry place, protected from sunlight. For special B2B conditions by volume, hospital supply agreements or validation of equivalents from other commercial houses, contact the technical-commercial team at Cahnos.





Reviews