Description
1. Product Presentation
At Cahnos we make available the non-absorbable polypropylene suture from the Premisut Prime range, reference AMP732GS6030, a professional solution for B2B supply to operating theatres, purchasing centres, general and specialist surgery services, as well as cardiology, ophthalmology and neurosurgery units.
This presentation incorporates a straight conventional cutting GS 60 mm needle with a 75 cm blue thread in USP 3/0 gauge, one of the most requested configurations for manual suturing on soft tissues with direct access. Prime quality, non-grooved surface, predictable behaviour and special conditions for hospital supply and volume contracts.
2. Technical explanation of the material and procedure
Polypropylene is a non-absorbable synthetic polymer presented as an uncoated monofilament, which gives it a smooth, non-grooved surface that slides gently through tissue, minimising the sawing effect and reducing tissue reaction. As it is not absorbed, the suture undergoes gradual encapsulation by connective tissue and maintains its tensile strength for more than three months, comfortably covering the critical healing phase.
The straight GS 60 mm needle, with a triangular conventional cutting point, allows precise penetration into soft tissues without tearing and is especially useful for continuous sutures, superficial approximations and direct-access ligatures. The blue colour ensures optimal visibility of the thread on the surgical field. The product is supplied sterile by ethylene oxide, is single-use and cannot be re-sterilised.
3. Technical Specifications
| Reference (SKU Cahnos) | AMP732GS6030 |
| Brand / Quality | Premisut – Prime |
| Material | Polypropylene, non-absorbable synthetic monofilament |
| Thread structure | Monofilament, non-grooved surface, uncoated |
| Gauge / USP size | USP 3/0 (metric 2) |
| Thread length | 75 cm |
| Thread colour | Blue (high visibility in the surgical field) |
| Needle shape | Straight |
| Tip type | Triangular, conventional cutting |
| Needle size | 60 mm (model GS 60) |
| Absorption | Non-absorbable; gradual encapsulation, wound support for more than 3 months |
| Sterilisation | Ethylene oxide (EO), sterile, single-use, not re-sterilisable |
| Tissue reaction | Minimal |
| Indications | Approximation of soft tissues, ligatures, cardiovascular surgery, ophthalmology and neurosurgery |
| Presentation | Box of 12 units |
3.1. Gauge equivalence
| USP size | Metric size | Approximate diameter |
| 3/0 | 2 | 0.20 – 0.249 mm (indicative according to Pharmacopoeia) |
Minimal tissue reaction, excellent tensile strength, secure knot and fully predictable behaviour as the polymer does not degrade in the body.
4. Equivalences and Cross-References
Non-absorbable monofilament polypropylene is one of the most widespread permanent suture families in the surgical market for soft tissue approximation and ligatures. The reference commercial ranges are Prolene (Ethicon / Johnson & Johnson), Surgipro and Monosof (Medtronic / Covidien), PremiCron (B. Braun) and the polypropylene lines from manufacturers such as Assut or Laboratorio Aragó.
There is no official equivalence table validated by the manufacturer that cross-references this specific configuration (straight conventional cutting GS 60 mm needle, USP 3/0 gauge, blue, 75 cm, Prime quality) with references from other manufacturers. Therefore, matches with other brands must be treated as functional category comparisons, not 1:1 interchangeable.
| Manufacturer / Company | Reference line | Equivalence level |
| Ethicon (Johnson & Johnson) | Prolene (monofilament polypropylene, blue, non-absorbable) | Comparable by category, not interchangeable 1:1 |
| Medtronic (Covidien) | Surgipro / Monosof (monofilament polypropylene) | Comparable by category, not interchangeable 1:1 |
| B. Braun | PremiCron (monofilament polypropylene, blue) | Comparable by category, not interchangeable 1:1 |
| Assut / Laboratorio Aragó | Polypropylene lines with straight needles | Comparable by category, not interchangeable 1:1 |
Before any formal substitution, check the alternative manufacturer’s technical data sheet for the exact gauge, thread length, needle geometry and size, colour, surface treatment and regulatory classification (CE/MDR). Consult our technical-commercial department before using this information in tenders or direct reference substitution. The brands cited belong to their respective manufacturers and are mentioned solely as an equivalence reference.
5. Selection tips and variants of interest
To choose the most suitable suture, consider the wound support time required by the tissue and the gauge according to the anatomical area: USP 3/0 (metric 2) is very versatile, indicated for skin, subcutaneous tissue, mucosa and soft tissues with moderate tension, as well as for precision approximation in cardiovascular surgery, ophthalmology and neurosurgery.
Always check the needle geometry: the straight GS conventional cutting needle is ideal for soft tissues with direct access and ligatures, while curved 3/8 circle formats with reverse cutting edge (DS series) are intended for deep sutures and closed planes.
Variants of interest within the Cahnos catalogue in Premisut polypropylene:
- AMP732GS6020: Prime polypropylene, straight GS 60 mm needle, USP 2/0, blue, 75 cm (larger gauge for ligatures with greater mechanical requirements).
- AM732GS6030: standard quality polypropylene, straight GS 60 mm needle, USP 3/0, blue, 75 cm (more economical profile).
- AMP731GR4530-2: Prime polypropylene with double straight needle, Taperpoint conical point 45 mm, USP 3/0, blue, 45 cm (continuous suture technique).
As this is a sterile single-use product, check the integrity of the packaging before each procedure, respect the expiry date and store it in a cool, dry place, protected from sunlight. For special B2B volume conditions, hospital supply agreements or equivalents from other commercial manufacturers, contact the technical-commercial team at Cahnos.