Description
1. Commercial Introduction
The Premisut Prime polypropylene suture is the reference choice for surgical departments, purchasing centres and tenders seeking a non-absorbable thread with predictable behaviour, minimal tissue reaction and a needle capable of penetrating tissues of moderate consistency with full control. This presentation in USP 5/0 gauge, with a double ⅜ circle needle and 17 mm trocar point (2xDRT17 Prime profile) and two 75 cm blue threads, is especially indicated for high-demand procedures: cardiovascular surgery, ophthalmology, neurosurgery and general surgery on soft tissues.
Supplied sterile and ready for single use in a box of 12 units with batch traceability, facilitating hospital stock management and presentation for public tenders. Available at Cahnos under the factory reference P732DRT1750-2 (SKU AMP732DRT1750-2), kept without altering characters.
2. Technical Explanation
Polypropylene is a synthetic linear polyolefin presented as an uncoated monofilament: lacking interstices and wicking effect, it offers very smooth sliding through tissue, does not favour bacterial adherence or the formation of sinuses in wounds at risk of contamination, and minimises thread extrusion. It is not absorbed or degraded by tissue enzymes: it maintains its tensile strength for a prolonged period, in accordance with USP and European Pharmacopoeia gauges, and is gradually encapsulated by connective tissue, helping the wound for more than three months.
The DRT 17 Prime needle (⅜ circle, cylindrical body with 17 mm Tapercut trocar point) combines the precise penetration of a sharp point with a non-cutting body that separates fibres without sectioning them: it passes through dense or slightly fibrous tissues with less resistance and without a cutting effect on adjacent tissue, reducing trauma and bleeding. The double-needle configuration allows continuous sutures or bilateral techniques without repositioning the needle in the needle holder. Sterilisation by ethylene oxide (EO); single-use product, not resterilisable.
3. Technical Specifications
| Parameter | Specification |
|---|---|
| Thread material | Polypropylene monofilament, uncoated, dyed blue |
| Thread structure | Non-grooved monofilament |
| Absorption | Non-absorbable; gradual encapsulation, wound support for more than 3 months |
| USP gauge / size | USP 5/0 (metric EP 1.0); conforming to USP and European Pharmacopoeia gauges |
| Thread length | 2 threads of 75 cm (2 × 75 cm) per unit |
| Thread colour | Identification blue |
| Needle shape | ⅜ circular (3/8 circle) |
| Needle body | Cylindrical |
| Tip type | Trocar (Tapercut) |
| Needle size | 17 mm (profile 2xDRT 17 Prime) |
| Configuration | Double needle (2xDRT) |
| Manufacturing quality | Prime (premium range) |
| Sterilisation | Ethylene oxide (EO) – sterile |
| Use | Single-use, sterile. Do not re-sterilise |
| Indications | Approximation of soft tissues, ligatures, cardiovascular surgery, ophthalmology and neurosurgery |
| Commercial presentation | Box of 12 units (individual sterile sachets) |
| Factory reference | P732DRT1750-2 |
| Reference Cahnos (SKU) | AMP732DRT1750-2 |
DRT 17 family (⅜ circle trocar point) in USP 5/0 gauge:
| Needle profile | Presentation | Reference |
|---|---|---|
| 2xDRT 17 Prime | 2 × 75 cm | P732DRT1750-2 / AMP732DRT1750-2 |
| DRT 17 Prime | 1 × 75 cm | P732DRT1750 / AMP732DRT1750 |
4. Equivalences and Cross-References
The reference P732DRT1750-2 corresponds to the official nomenclature of the Premisut Prime range (2xDRT 17 Prime profile, double 75 cm thread). Cahnos markets the product keeping the factory reference without altering characters. There is no official equivalence table validated by the manufacturer that cross-references this reference with other brands; the following comparisons are functional, at category level, and must be confirmed against the technical data sheet or instructions for use (IFU) of each manufacturer before use in tenders or substitution.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
|---|---|---|---|---|
| Premisut Prime range (Cahnos) | Polypropylene 2xDRT 17 Prime, USP 5/0, blue, 2 × 75 cm | P732DRT1750-2 / AMP732DRT1750-2 | Direct product reference | Product analysed in this data sheet |
| Premisut Prime range (Cahnos) | Polypropylene DRT 17 Prime, USP 5/0, blue, 1 × 75 cm | AMP732DRT1750 | Configuration equivalent within the same system | Same DRT 17 needle and USP 5/0 gauge; changes to a single 75 cm thread |
| Ethicon (Johnson & Johnson MedTech) | PROLENE® – blue monofilament polypropylene, USP 5/0, 75 cm, double V-4 needle of 17 mm, 3/8 circle TAPERCUT | F2829 | Functional equivalence by specifications (no official cross-reference table) | Matches in material, gauge, colour, double needle, thread length (75 cm) and needle geometry (17 mm, 3/8, trocar point). Presentation in box of 36 units; confirm batch and presentation against IFU |
| B. Braun | Premilene® / Optilene® (polypropylene with polyethylene, blue monofilament, USP 5/0) | X2090319 (Premilene 5/0, 75 cm, DRT18 single needle); C3090719 (Optilene 5/0, 75 cm, 2xDR18 double needle) | Comparable by category / pending 1:1 confirmation | Same blue polypropylene base, EP 1 gauge and length; needle designated DR/DRT of 18 mm versus 17 mm; verify arc, point and number of needles in the manufacturer’s technical data sheet |
| Medtronic (Covidien) | Surgipro™ II (polypropylene with polyethylene, blue monofilament) | VP580X (USP 5/0, blue, 36″, double CV-15 needle, 3/8 circle) | Comparable by category / pending confirmation | Copolymer with polyethylene; matches in gauge, colour and needle family; 90 cm strand versus 2 × 75 cm; verify exact needle size and presentation against IFU |
| Serag-Wiessner | SERAPREN® (blue polypropylene monofilament, USP 8/0 to 0) | 2x DR-17 blue profile, USP 5/0, 75 cm – consult order code according to catalogue (e.g. CO10xxxx series) | Comparable by category / pending confirmation | Double trocar needle profile 17 mm very close; confirm needle arc and official code with the distributor |
| Vitrex (Chirana) | Chiralen (blue monofilament polypropylene) | 4022PP 5310 (Chiralen 5/0, DRT13, 75 cm, 3/8 trocar needle of 13 mm) | Comparable by category / not interchangeable 1:1 | Same material, gauge and length (75 cm) with 3/8 trocar point; 13 mm needle versus 17 mm and box of 24 units; verify double needle format |
Mandatory technical note: there is no equivalence table validated by the manufacturer that cross-references this reference with other brands; comparisons with PROLENE®, Premilene®/Optilene®, Surgipro™ II, SERAPREN® or Chiralen are functional, at category level, and must be confirmed against the technical data sheet or IFU of each manufacturer before use in tenders. Consult the technical department of Cahnos to validate any equivalence before substituting the product.
5. Selection tips and variants of interest
- Tissue to suture: the DRT trocar point needle (Tapercut) is suitable for tissues of moderate or slightly fibrous consistency that require firm penetration with minimal aggression (skin, mucosa, subcutaneous tissue, ophthalmology and vascular planes). For very friable tissues, consider conical point profiles (DR) or other profiles from the same Premisut Prime range.
- Needle size: the 17 mm DRT is a medium-length needle, ideal for reduced surgical fields; if you need a shorter needle, the 13 mm DRT family is available in the same gauge (AMP732DRT1350 / AMP732DRT1350-2); for wider planes, the 25 mm DRT family in other gauges from the Premisut catalogue.
- Gauge: USP 5/0 (metric 1.0) offers the balance between strength and manageability for fine tissues or moderate tension; for greater support consider USP 4/0 with the same DRT 17 needle (AMP732DRT1740 / AMP732DRT1740-2) or USP 3/0 (AMP732DRT1730).
- Presentation: the single-needle version (AMP732DRT1750, 1 × 75 cm) reduces the unit cost for occasional uses; the double needle in this listing (2 × 75 cm) maximises thread utilisation and facilitates continuous sutures or anastomoses.
- Alternative geometry: if you prefer a ½ circle arc with a 17 mm trocar point in 5/0, refer to the HRT variant of the same range (AMP732HRT1750); the choice of arc depends on the approach and depth of the surgical field.
- Sterility verification: product sterile by ethylene oxide, single-use; check the integrity of the blister and the expiry date before each use and keep the reference P732DRT1750-2 and the batch number for traceability in the operating theatre and in case of complaint.





Reviews