Description
1. Product Presentation
The PREMISUT PRIME polypropylene suture we offer at Cahnos is a highly reliable solution for closing and approximating soft tissues. It is a non-absorbable, blue monofilament suture with excellent mechanical performance and minimal tissue reaction, designed for professionals who demand precision and safety in every procedure. It is supplied in a box of 12 units, each with 2 threads of 90 cm mounted on a ⅜ circle needle with a 45 mm reverse cutting triangular point (model DS45). Its Prime finish provides a needle with a ribbed body and improved penetration, ideal for operating theatres, purchasing centres and tenders.
2. Technical Explanation
Polypropylene is a linear synthetic polymer (polyolefin) that is presented as an uncoated monofilament. Being non-absorbable, the thread does not degrade: it is gradually encapsulated by the tissue and maintains its tensile strength for more than three months, making it the classic choice for cardiovascular, vascular and long-term suture surgery. The ⅜ circle needle with a reverse cutting triangular point (reverse cutting) easily penetrates firm and fibrous tissues, while its ribbed body facilitates passage through tissue, minimising trauma. The blue colour of the strand improves visibility and control of the thread during surgery. Ethylene oxide sterilisation guarantees sterile delivery ready for the operating theatre; single-use product, not re-sterilisable.
3. Technical Specifications
| Characteristic | Specification |
| Brand / Line | Premisut Prime |
| Material | Polypropylene (polypropylene), monofilament, uncoated |
| Absorption | Non-absorbable (gradual encapsulation, no loss of tension, support exceeding 3 months) |
| Colour | Blue |
| Gauge | USP 1 (metric 4) |
| Needle shape | ⅜ circle (3/8 circular) |
| Needle tip | Reverse cutting triangular (reverse cutting), grooved body |
| Needle size | 45 mm (model DS45) |
| Number of threads | 2 |
| Thread length | 2 x 90 cm |
| Sterilisation | Ethylene oxide (EO) |
| Use | Single-use, sterile. Do not re-sterilise |
| Indications | Approximation of soft tissues, ligatures, cardiovascular surgery, ophthalmology and neurosurgery |
| Presentation | Box of 12 units |
| Factory reference | P733DS4501.2 |
| Reference Cahnos (SKU) | AMP733DS4501.2 |
4. Equivalences and Cross-References
Within Cahnos’s own catalogue there are references from the same Premisut/Polypropylene family with equivalent or comparable technical configuration:
| Manufacturer / Brand | Family / Model | Code / SKU | Equivalence level | Technical differences / Remarks |
| Cahnos (Premisut Prime) | Polypropylene 3/8 DS45, USP 1, blue, 2 x 90 cm | AMP733DS4501.2 | Direct product reference | Product analysed in this technical data sheet (factory ref. P733DS4501.2) |
| Cahnos (Premisut Prime) | Polypropylene 3/8 DS45, USP 1, blue, 90 cm | AMP733DS4501 | Direct range equivalent (number of strands varies) | Same DS45 needle, same gauge and colour; presentation of 1 thread of 90 cm instead of 2 |
| Cahnos (Premisut) | Polypropylene 3/8 DS45, USP 1, blue, 90 cm | AM733DS4501 | Functional category equivalent | Same geometry; standard quality (not Prime), 1 thread of 90 cm |
| Cahnos (Premisut Prime) | Polypropylene 3/8 DS45, USP 2/0, blue, 2 x 90 cm | AMP733DS4520.2 | Comparable by category | Same DS45 needle and 2 x 90 cm presentation; USP 2/0 gauge of smaller diameter |
| Cahnos (Premisut Prime) | Polypropylene 3/8 DS45, USP 0, blue, 2 x 90 cm | AMP733DS4510.2 | Comparable by category | Same DS45 needle and presentation; USP 0 gauge of smaller diameter |
| Ethicon (J&J MedTech) | PROLENE® – blue monofilament polypropylene | Specific code to be confirmed (e.g. series NW879 / 8523 in cardiovascular gauges and needles) | Pending confirmation | Reference suture in cardiac and vascular surgery; verify with the manufacturer needle geometry (⅜ reverse cutting, 45 mm), USP 1 and 90 cm length before substituting |
| B. Braun | Premilene® – blue polypropylene monofilament (Easyslide needles) | Series C2090 (e.g. C2090100, Premilene 1 / 100 cm with HR40 needle) | Comparable by category / pending confirmation | Same base material and gauge; confirm ⅜ reverse cutting needle of 45 mm and 2 x 90 cm presentation in official catalogue. Not interchangeable 1:1 without verification |
| Medtronic / Covidien | Surgipro™ II – polypropylene with polyethylene, blue | PP44620 (2/0, CT25 ⅜ reverse cutting needle, 75 cm) | Comparable by category | Same material and indication; 25 mm needle and 75 cm thread, not interchangeable 1:1 with the 45 mm DS45 needle |
| Serag-Wiessner | SERAPREN® – blue polypropylene monofilament | Consult code according to gauge and needle | Comparable by category | Blue non-absorbable polypropylene monofilament; verify gauge, needle geometry and lengths with the distributor. |
Technical note: there is no official equivalence table validated by the manufacturer that cross-references this product with other brands; comparisons with PROLENE®, Premilene®, Surgipro™ or SERAPREN® are functional, at category level, and must be confirmed against the technical data sheet or instructions for use (IFU) of each manufacturer before use in tenders or substitution. Consult Cahnos’s technical department to validate any equivalence before use.
5. Selection tips and variants of interest
- Number of threads: the 2 x 90 cm presentation (AMP733DS4501.2) is indicated for surgeries requiring multiple passes or long sutures; if you prefer a single 90 cm thread, the reference AMP733DS4501 is available.
- Gauge: USP 1 offers high tensile strength for deep planes, fasciae and tension ligatures; for tissues with lower resistance, the same DS45 needle is available in USP 0 (AMP733DS4510.2) and USP 2/0 (AMP733DS4520.2).
- Needle length: DS45 (45 mm) for deep planes or thick tissues; in the same family you have DS40 (40 mm, USP 1: AMP733DS4001), DS36 and DS30 for more superficial planes.
- Prime quality: the Prime range provides a superior needle finish with a ribbed body and improved penetration, compared to the standard Premisut line.
- Sterility verification: product sterile by ethylene oxide, single-use; check the integrity of the blister and the expiry date before each use and keep the reference P733DS4501.2 and the batch number for traceability in the operating theatre.





Reviews