Description
1. Commercial Introduction
The Premisut polypropylene suture in USP 0 gauge is the reference solution for surgical departments, purchasing centres and tenders that require a non-absorbable thread with predictable behaviour, excellent handling and minimal tissue reaction. Its ⅜ circle needle with a 24 mm reverse cutting triangular point (DS24 profile) provides firm, controlled penetration in soft tissues, while the 75 cm blue monofilament ensures high visibility in the field and high tensile strength.
It is supplied sterile and ready for the operating theatre in a box of 12 units with batch traceability, facilitating hospital stock management and presentation for public tenders. A very competitive price-quality ratio compared with the major brands on the market.
2. Technical Explanation
Polypropylene is a synthetic linear polyolefin extruded as an uncoated monofilament: as it has no interstices and no wicking effect, it slides very smoothly through tissue, does not promote bacterial adherence or the formation of sinuses in wounds at risk of contamination, and minimises thread extrusion. It is not absorbed or degraded by tissue enzymes: it is gradually encapsulated by fibrous connective tissue and maintains its tensile strength for more than three months, comfortably covering the critical healing phase.
The ⅜ circle needle with a reverse cutting triangular point places the cutting edge on the outer side of the curve, allowing firm, non-distensible tissues (skin, fascia, subcutaneous) to be traversed with a clean, stable cut, minimising the risk of tearing; the fluted finish of the thread facilitates smooth, consistent delivery during knotting. The blue colour provides optimal visibility on the surgical field. Sterilisation by ethylene oxide (EO); single-use product, not re-sterilisable.
3. Technical Specifications
| Characteristic | Specification |
| Factory reference | 732DS2410 |
| Reference Cahnos (SKU) | AM732DS2410 |
| Brand / Quality | Premisut – standard quality |
| Thread material | Polypropylene monofilament, uncoated, dyed blue |
| Thread structure | Monofilament with grooved surface |
| Absorption | Non-absorbable; gradual encapsulation, wound support for more than 3 months |
| Gauge / USP size | USP 0 (metric 3.5) |
| Approximate thread diameter | 0.350 – 0.399 mm (indicative, non-absorbable suture according to USP Pharmacopoeia) |
| Thread length | 75 cm (1 thread per unit) |
| Thread colour | Identification blue, fluted (high visibility in the surgical field) |
| Needle shape | ⅜ circular (3/8 circle) |
| Needle type | Reverse cutting triangular point, fluted body and point (DS profile) |
| Needle size | 24 mm (DS24 profile) |
| Sterilisation | Ethylene oxide (EO); sterile, single-use, non-resterilisable |
| Indications | Approximation of soft tissues, ligatures, cardiovascular surgery, ophthalmology and neurosurgery |
| Presentation | Box of 12 units (individual sterile sachets) |
Range Premisut DS24 (⅜ circle needle, fluted reverse cutting triangular point, blue, 75 cm):
| USP size | Line reference | SKU Cahnos |
| 4/0 | 732DS2440 | AM732DS2440 |
| 3/0 | 732DS2430 | AM732DS2430 |
| 2/0 | 732DS2420 | AM732DS2420 |
| 0 | 732DS2410 | AM732DS2410 (this product) |
| 1 | 732DS2401 | AM732DS2401 |
4. Equivalences and Cross-References
Non-absorbable monofilament polypropylene is one of the most widespread permanent suture families in the surgical market; the reference commercial ranges are PROLENE® (Ethicon / Johnson & Johnson MedTech), Premilene® and Optilene® (B. Braun), Surgipro™ II (Medtronic / Covidien) and SERAPREN® (Serag-Wiessner). Important: there is no official equivalence table validated by the manufacturer that cross-references this specific reference against other brands; comparisons between brands are functional, at category level, and must be confirmed against each manufacturer’s technical data sheet or IFU before use in tenders or direct substitution. Consult the Cahnos technical department to validate any equivalence.
| Manufacturer / Brand | Family / Model | Code / SKU | Equivalence level | Differences / Notes |
| Cahnos (Premisut Prime) | Polypropylene 3/8 DS24 Prime, USP 0, blue, 75 cm | P732DS2410 (AMP732DS2410) | Direct equivalent within the catalogue | Same DS24 needle, same gauge, colour and length; Prime quality with fluted needle and improved penetration |
| Cahnos (Premisut Prime) | Polypropylene 3/8 DS24, USP 0, blue, 2 × 75 cm | P732DS2410.2 (AMP732DS2410.2) | Direct equivalent (double presentation) | Same needle and gauge; 2 threads of 75 cm per unit |
| Ethicon (J&J MedTech) | PROLENE® – blue monofilament polypropylene, USP 0, 75 cm, FSLX 3/8 reverse cutting needle | 8690H | Comparable by category, not interchangeable 1:1 | Matches in material, gauge, colour and length; FSLX needle of 36 mm versus the DS24 of 24 mm; pack of 36 units |
| Ethicon (J&J MedTech) | PROLENE® – blue monofilament polypropylene, USP 0, 75 cm, CP-1 reverse cutting needle | F2825 | Comparable by category, not interchangeable 1:1 | Matches in material, gauge, colour and length; CP-1 needle of smaller size than the DS24 (24 mm); pack of 36 units |
| Medtronic / Covidien | Surgipro™ II – copolymer of polypropylene with polyethylene, blue, USP 0, 30″ (≈76 cm), C-17 3/8 reverse cutting needle | SP690 | Comparable by category, not interchangeable 1:1 | Copolymer material (not pure polypropylene); C-17 needle of 39 mm with different geometry from the DS24; pack of 36 units |
| B. Braun (Aesculap) | Premilene® – blue monofilament polypropylene, USP 0 (EP 3.5), 75 cm, HR26S ½ circle needle | C2095443 | Comparable by category / pending confirmation | Same blue polypropylene base and gauge; HR26S ½ circle needle (round point) versus the ⅜ DS24 reverse cutting; verify geometry in the official B. Braun catalogue. |
| Serag-Wiessner | SERAPREN® – blue monofilament polypropylene, USP 0, 75 cm, DS-30 3/8 reverse cutting needle | CO353416 | Comparable by category, not interchangeable 1:1 | Same material, gauge, colour and length; DS-30 needle of 30 mm versus the DS24 of 24 mm; pack of 24 units |
Technical note: before any formal substitution, verify in the alternative manufacturer’s technical data sheet the exact gauge, thread length, needle geometry and size, colour, surface treatment and regulatory classification (CE/MDR) of the actual product. The brands cited belong to their respective manufacturers and are mentioned solely as an equivalence reference.
5. Selection tips and variants of interest
Tissue to be sutured: the fluted reverse cutting DS needle is suitable for soft tissues and flat skin planes that require firm, controlled penetration (cardiovascular surgery, ophthalmology, neurosurgery and general surgery). For lax or vascular tissues, consider conical point profiles from the same Premisut range.
Needle size: the DS24 is a medium-length needle, ideal for superficial planes and areas with limited access; for wider fields, the DS26 (AM732DS2610), DS30 or DS36 are available in the same USP 0 gauge.
Gauge: USP 0 (metric 3.5) offers an excellent balance between handling and tension; with the same DS24 needle, variants 4/0 (AM732DS2440), 3/0 (AM732DS2430), 2/0 (AM732DS2420) and USP 1 (AM732DS2401) are available for greater mechanical demand.
Presentation: if you prefer the premium range, the Prime version (AMP732DS2410) maintains the same needle and configuration with an improved fluted finish, and the double presentation 2 × 75 cm (AMP732DS2410.2) reduces the opening of packaging per procedure.
Sterility and traceability: product sterile by ethylene oxide and single-use; check the integrity of the blister and the expiry date before each use and keep the reference 732DS2410 and the batch number for traceability in the operating theatre.





Reviews
There are no reviews yet.