Description
1. Commercial Introduction
The suture Premisut Prime AMP732DS2420 is the reference choice for surgical departments, purchasing centres and tenders that require a non-absorbable suture with predictable behaviour, excellent handling and minimal tissue reaction. Its ⅜ circle needle with a grooved reverse cutting triangular point of 24 mm (DS24 profile) offers firm, controlled penetration in soft tissues and skin planes, while the 75 cm blue polypropylene monofilament ensures a clean suture with high tensile strength and excellent visibility in the field.
It is supplied sterile, ready for the operating theatre, in a box of 12 units with individual sachets and batch traceability, which facilitates hospital stock management and submission to public tenders. Available under the factory reference P732DS2420 (SKU Cahnos AMP732DS2420), with the characters unchanged.
2. Technical Explanation
Polypropylene is a synthetic linear polyolefin extruded as an uncoated monofilament. Lacking interstices and wicking effect, it offers very smooth passage through tissue, does not promote bacterial adherence or the formation of sinuses in wounds at risk of contamination, and minimises suture extrusion. It is not absorbed or degraded by tissue enzymes: it becomes gradually encapsulated by fibrous connective tissue and maintains its tensile strength for more than three months, comfortably covering the critical healing phase.
The ⅜ circle needle with a reverse cutting triangular point (inverted triangular or reverse cutting) places the cutting edge on the outer side of the curve, allowing firm, poorly distensible tissues (skin, fascia, subcutaneous) to be traversed with a clean, stable cut, minimising the risk of tearing. The Prime finish provides a grooved needle body with improved penetration and a more resistant tip compared to standard quality, and the grooved blue suture facilitates smooth, consistent delivery during knotting. Ethylene oxide (EO) sterilisation guarantees sterile delivery; single-use product, not re-sterilisable.
3. Technical Specifications
| Parameter | Specification |
| Brand / Quality | Premisut Prime (premium range, grooved needle) |
| Thread material | Polypropylene monofilament, uncoated, dyed blue |
| Thread structure | Monofilament with grooved surface |
| Absorption type | Non-absorbable; gradual encapsulation, wound support for more than 3 months |
| Gauge / USP size | USP 2/0 (metric EP 3); diameter 0.30 – 0.34 mm per USP Pharmacopoeia |
| Thread length | 75 cm (1 thread per unit) |
| Thread colour | Blue identifier, grooved surface (high visibility in the field) |
| Needle shape | ⅜ circular (3/8 circle) |
| Needle type | Reverse-cutting triangular point, grooved, DS profile |
| Needle size | DS24 (24 mm) Prime |
| Sterilisation | Ethylene oxide (EO) – sterile, single-use, not resterilisable |
| Indications | Approximation of soft tissues, ligatures, cardiovascular surgery, ophthalmology and neurosurgery |
| Presentation | Box of 12 units (individual sterile sachets) |
| Factory reference | P732DS2420 |
| Reference Cahnos (SKU) | AMP732DS2420 |
Premisut Prime DS24 range (⅜ circle needle, reverse-cutting triangular grooved point, blue, 75 cm)
| USP size | Presentation | Factory reference | SKU Cahnos |
| 4/0 | 1 × 75 cm | P732DS2440 | AMP732DS2440 |
| 3/0 | 1 × 75 cm | P732DS2430 | AMP732DS2430 |
| 2/0 | 1 × 75 cm | P732DS2420 | AMP732DS2420 (this product) |
| 2/0 | 2 × 75 cm | P732RDS2420.2 | AMP732DS2420.2 |
| 0 | 1 × 75 cm | P732DS2410 | AMP732DS2410 |
| 1 | 1 × 75 cm | P732DS2401 | AMP732DS2401 |
4. Equivalences and Cross-References
Important: there is no equivalence table validated by the manufacturer that cross-references this product with other brands; the comparisons indicated below are functional category comparisons, not interchangeable 1:1, unless expressly stated. They must be confirmed against the technical data sheet or instructions for use (IFU) of each manufacturer before use in tenders or direct substitution. Contact the technical department of Cahnos to validate any equivalence.
| Manufacturer / Brand | Family / Model | Code / SKU | Equivalence level | Technical differences / Remarks |
| Cahnos (Premisut Prime) | Polypropylene 3/8 DS24, USP 2/0, blue, 2 × 75 cm | AMP732DS2420.2 (Ref. P732RDS2420.2) | Direct equivalence within the catalogue (double thread configuration) | Same DS24 needle, same gauge 2/0, same colour and material; only the number of threads per pack changes (1 vs 2). |
| Cahnos (Premisut, standard quality) | Polypropylene 3/8 DS24, USP 2/0, blue, 75 cm | AM732DS2420 (Ref. 732DS2420) | Direct equivalence within the catalogue (standard quality) | Same needle geometry and gauge; the Prime finish (grooved needle with improved penetration) and suture quality vary. |
| B. Braun (Aesculap) | Optilene® DS24 (M) – blue non-absorbable monofilament, USP 2/0 (3), 75 cm, DS24 Easyslide needle, Race-Pack | C3090236 | Reference equivalence by needle geometry (verified in the official B. Braun catalogue); copolymer composition, not interchangeable 1:1 without validation. | DS24 needle identical in ⅜ curvature and 24 mm reverse cutting point, same gauge and length; copolymer material of polypropylene + polyethylene versus pure polypropylene. Race-Pack packaging of 36 units. |
| Medtronic / Covidien | Surgipro™ II – polypropylene copolymer with polyethylene, blue, CT25 needle (25 mm) 3/8 reverse cutting, 75 cm, USP 2/0 | PP44620 | Comparable by category, not interchangeable 1:1 | CT25 needle (25 mm) versus DS24 (24 mm); same 3/8 curvature, gauge and suture length. Copolymer material; check point geometry and traceability against the IFU. |
| Atramat | Polypropylene CE24 (PE-24), 24 mm 3/8 reverse-cutting needle, USP 2/0, 75 cm | CE2462-75 | Comparable by category, not interchangeable 1:1 | Same needle dimensions (24 mm) and curvature; verify Prime quality versus conventional version, grooving and commercial presentation. |
| Ethicon (J&J MedTech) | PROLENE® – blue polypropylene monofilament, USP 2/0, FS reverse-cutting needle | W8026T (45 cm) / 8685H (FS, 75 cm series) | Not verified for 75 cm with 24 mm needle – consult Ethicon representative | The PROLENE PS-2/SC-24 range exists in 45 cm; for 75 cm with a 24 mm needle, no consistent public code was found. Confirm with the manufacturer before tendering. |
| Serag-Wiessner | SERAPREN® – blue polypropylene monofilament, DS reverse-cutting needle | Pending confirmation for USP 2/0 DS24 | Not verified | Sector family with DS-25 needle (25 mm) very close to the DS24; confirm gauge, needle size and presentation in the official catalogue before any use. |
Mandatory technical note: the references from other manufacturers cited come from official catalogues or verified authorised distributors; formal substitution requires verifying USP gauge, needle size and geometry, suture length, colour, surface treatment and regulatory classification (CE/MDR) in the alternative manufacturer’s documentation.
5. Selection tips and variants of interest
- Tissue to suture: the grooved reverse cutting DS needle is suitable for soft tissues and skin planes that require firm, controlled penetration (skin, fascia, subcutaneous, cardiovascular surgery, ophthalmology and neurosurgery). For lax or vascular tissues, consider round point profiles (HR) from the same Premisut Prime range.
- Gauge: USP 2/0 (metric 3) is versatile for soft tissues and medium-tension ligatures. With the same DS24 Prime needle, it is available in USP 4/0 (AMP732DS2440), 3/0 (AMP732DS2430), 0 (AMP732DS2410) and USP 1 (AMP732DS2401).
- Presentation: for high consumption, the double suture format 2 × 75 cm (AMP732DS2420.2) is available; if you prefer a more economical alternative, the standard Premisut quality (AM732DS2420) maintains the needle and configuration.
- Pre-substitution verification: always check curvature (⅜ circle), needle length (24 mm), point type (reverse cutting triangular, not to be confused with conical point), USP gauge 2/0 and number of sutures per pack before approving any change of supplier or reference.
- Sterility and traceability: sterile product by ethylene oxide and single-use; check the integrity of the blister and the expiry date before each use and keep the reference P732DS2420 and the batch number for traceability in the operating theatre.
For B2B volume conditions, hospital supply agreements or validation of equivalents from other commercial brands, contact the technical-commercial team of Cahnos.





Reviews
There are no reviews yet.