Description
The polypropylene suture Premisut is the reference solution for surgical departments, purchasing centres and tenders that require a non-absorbable thread with predictable behaviour, excellent handling and minimal tissue reaction. This presentation incorporates a ⅜ circle needle with a reverse cutting triangular point of 16 mm (DS16 profile), USP 5/0 gauge and a 45 cm strand in high-visibility blue: a fine and precise configuration, widely used in superficial planes, delicate tissues, ligatures and procedures in cardiovascular surgery, ophthalmology, neurosurgery and general surgery. It is supplied sterile, ready for single use and with batch traceability, facilitating hospital stock management and submission to public tenders. It is supplied in a box of 12 units under the factory reference 731DS1650 (SKU Cahnos AM731DS1650).
Technical product explanation
Polypropylene is a synthetic linear polyolefin (propylene polymer) that is presented as an uncoated monofilament: lacking interstices and wicking effect, it offers very smooth sliding through tissue, does not favour bacterial adherence or the formation of sinuses in wounds at risk of contamination, and minimises thread extrusion. It is not absorbed nor degraded by tissue enzymes: it maintains its tensile strength over a prolonged period, in accordance with USP and European Pharmacopoeia gauges, and is gradually encapsulated by fibrous connective tissue, helping the wound for more than three months. The DS16 needle of ⅜ circle with reverse cutting triangular point penetrates soft and poorly distensible tissues with a clean and stable cut: the reverse cutting geometry supports the cutting edge towards the outer part of the curve, which reduces the risk of tearing in firm tissues and allows controlled passage, even in reduced access planes or microsurgery. The blue colour of the thread guarantees optimal visibility in the surgical field. Sterilisation by ethylene oxide (EO); single-use product, not re-sterilisable.
Technical specifications
Data verified according to the technical data sheet and instructions for use of the Premisut range (Cahnos S.L.).
| Parameter | Specification |
| Brand / Quality | Premisut (standard quality, DS16 needle) |
| Thread material | Polypropylene monofilament, uncoated, dyed blue |
| Thread structure | Monofilament |
| Absorption | Non-absorbable; gradual encapsulation, wound support for more than 3 months |
| Gauge / USP size | USP 5/0 (metric EP 1); conforms to USP and European Pharmacopoeia gauges |
| Thread diameter | 0.100 – 0.149 mm (according to USP Pharmacopoeia, non-absorbable suture) |
| Thread length | 45 cm (1 strand per unit) |
| Thread colour | Identification blue (high visibility in the surgical field) |
| Needle shape | ⅜ circular (3/8 circle) |
| Needle type | Triangular reverse cutting point, body and point (DS profile) |
| Needle size | 16 mm (DS16 profile) |
| Tensile strength | High tensile strength; maintains integrity for more than three months |
| Sterilisation | Ethylene oxide (EO) – sterile |
| Use | Single-use, sterile. Do not re-sterilise |
| Indications | Approximation of soft tissues, ligatures, cardiovascular surgery, ophthalmology and neurosurgery |
| Commercial presentation | Box of 12 units (sterile individual sachets); batch traceability |
| Factory reference | 731DS1650 |
| Reference Cahnos (SKU) | AM731DS1650 |
Family Premisut DS (⅜ circle needle, reverse cutting triangular point, blue)
| Needle profile | USP size | Thread | Reference |
| DS16 (standard) | 5/0 | 45 cm | 731DS1650 / AM731DS1650 (this product) |
| DS16 Prime | 5/0 | 45 cm | P731DS1650 / AMP731DS1650 |
| DS16 (standard) | 6/0 | 45 cm | 731DS1660 / AM731DS1660 |
| DS19 (standard) | 5/0 | 45 cm | 731DS1950 / AM731DS1950 |
| DS19 Prime | 5/0 | 45 cm | P731DS1950 / AMP731DS1950 |
Equivalences and cross-references
Reference 731DS1650 corresponds to the official nomenclature of the Premisut range (DS16 profile, single 45 cm thread, USP 5/0 gauge, standard quality). Cahnos markets the product keeping the factory reference without altering characters. There is no official equivalence table validated by the manufacturer that cross-references this reference with other brands; the following comparisons are functional, at category level, and must be confirmed against the technical data sheet or instructions for use (IFU) of each manufacturer before use in tenders or direct substitution.
| Manufacturer / Brand | Family / Model | Code / SKU | Equivalence level | Technical differences / Remarks |
| Cahnos (Premisut Prime) | Polypropylene DS16 Prime, USP 5/0, blue, 45 cm | AMP731DS1650 (P731DS1650) | Direct range equivalent | Same DS16 needle, gauge, colour and length; Prime finish with grooved needle |
| Cahnos (Premisut) | Polypropylene DS16, USP 6/0, blue, 45 cm | AM731DS1660 | Direct range equivalent | Same DS16 needle and length; 6/0 gauge of smaller diameter for microsurgery |
| Cahnos (Premisut) | Polypropylene DS19, USP 5/0, blue, 45 cm | AM731DS1950 | Direct range equivalent | Same gauge, colour and length; DS19 needle of 19 mm versus DS16 of 16 mm |
| Ethicon (J&J MedTech) | PROLENE® – blue monofilament polypropylene, P-3 3/8 precision reverse cutting needle, 5/0, 45 cm | 8698G | Comparable by category, not interchangeable 1:1 | Code verified in authorised distribution sources: same material, gauge, colour and 45 cm; P-3 needle of 13 mm versus DS16 of 16 mm. Confirm CE/MDR traceability against IFU |
| Medtronic (Covidien) | Surgipro™ II – polypropylene monofilament with polyethylene, P-13 reverse cutting ⅜ circle needle, 5/0, 45 cm | SP5698G | Comparable by category, not interchangeable 1:1 | Code verified in authorised distribution: polypropylene/polyethylene copolymer (not pure polypropylene), needle of 13 mm versus 16 mm; verify reference and batch against IFU |
| B. Braun (Aesculap) | Premilene® – blue polypropylene monofilament, 5/0 | 5/0 code not verified in this consultation | Comparable by category, not verified | Same base material and gauge; confirm needle geometry and exact reference in official catalogue before use |
| Serag-Wiessner | SERAPREN® – blue polypropylene monofilament | 5/0 code not verified in this consultation | Comparable by category, not verified | Same base material (blue monofilament polypropylene); confirm code, needle and presentation in official catalogue before use |
Mandatory technical note: there is no equivalence table validated by the manufacturer that cross-references this reference with other brands; comparisons with PROLENE®, Surgipro™ II, Premilene® or SERAPREN® are functional, at category level, and must be confirmed against the technical data sheet or IFU of each manufacturer before use in tenders or substitution. Consult the technical department of Cahnos to validate any equivalence before use.
Selection tips and variants of interest
Tissue to suture: the DS16 reverse cutting needle is suitable for soft tissues and skin planes that require firm and controlled penetration in reduced access areas (cardiovascular surgery, ophthalmology, neurosurgery and general surgery). For lax or vascular tissues, consider round point profiles (HR) from the same Premisut range.
Needle size: the DS16 of 16 mm is a compact needle, ideal for superficial planes, microsurgery and surgical fields with limited space. If the protocol requires a longer needle path in the same USP 5/0 gauge, the DS19 variant (AM731DS1950) is available and, in premium finish with grooved needle, the Premisut Prime family (AMP731DS1650).
Alternative gauges with the same DS16 needle: USP 6/0 (AM731DS1660) for ophthalmic and cardiovascular microsurgery of maximum fineness. In the DS19 family you will also find USP 3/0 (AM731DS1930) and USP 4/0 (AM731DS1940) for greater mechanical demand or delicate tissues.
Length and presentation: this 45 cm reference is a compact presentation for short passes or limited fields; for sutures with longer path, versions of 75 cm are available within the DS family. This needle geometry is interchangeable within the Premisut system itself, allowing supplier unification across the entire permanent suture portfolio.
Sterility verification: sterile product by ethylene oxide and single-use; check the integrity of the blister and the expiry date before each use and keep the reference 731DS1650 and the batch number for traceability in the operating theatre and in case of complaint. For special B2B conditions by volume, hospital supply agreements or equivalents from other commercial houses, contact the technical-commercial team of Cahnos.






Reviews
There are no reviews yet.