We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice

Polypropylene suture Premisut Prime 1/2 circle, trocar point (Tapercut) HRT 17 mm – USP 3/0, blue, 75 cm | Box of 12 units (Ref. P732HRT1730)

27,65 €

Non-absorbable polypropylene monofilament suture Premisut Prime. 1/2 circle needle with trocar point (Tapercut), 17 mm, USP 3/0 gauge, blue thread 75 cm, uncoated and with wound support for more than three months thanks to its gradual encapsulation. Sterilised by ethylene oxide, single-use, indicated for approximation of soft tissues, ligatures and cardiovascular surgery, ophthalmology and neurosurgery. Manufacturer’s ref. P732HRT1730 (SKU AMP732HRT1730), presentation in a box of 12 units with individual sterile envelopes.

International shipping. Import duties and taxes are payable by the recipient.

Reference
AMP732HRT1730

Description

1. Commercial Introduction

The Premisut Prime polypropylene suture is the reference choice for surgery departments, purchasing centres and tenders looking for a non-absorbable thread with predictable behaviour, maximum tensile strength and minimal tissue reaction. This presentation incorporates a ½ circle trocar point (Tapercut) needle of 17 mm (HRT profile), USP gauge 3/0 and blue strand of 75 cm, a configuration especially indicated for cardiovascular surgery, ophthalmology and neurosurgery, as well as for approximation and ligation of soft tissues.

It is supplied sterile, ready for immediate use, in a box of 12 units with individual pouches and batch traceability. Available at Cahnos with factory reference P732HRT1730 (SKU AMP732HRT1730), kept unchanged.

2. Technical Explanation

Polypropylene is a linear synthetic polyolefin that is presented as an uncoated monofilament: lacking interstices and wick effect, it offers very smooth sliding through tissue, does not promote bacterial adherence and minimises suture extrusion. Being non-absorbable, it is not degraded by tissue enzymes: it is gradually encapsulated by fibrous connective tissue and maintains its tensile strength for more than three months, easily covering the critical healing phase.

The HRT needle (½ circle, cylindrical body) with trocar point or Tapercut combines the firm penetration of a cutting point with a non-cutting body, allowing it to pass through slightly fibrous tissues, vascular adventitia or calcified walls with less resistance and without tearing the suture bed. The blue strand ensures optimal visibility on the surgical field. Sterilisation by ethylene oxide (EO); single-use product, not re-sterilisable.

3. Technical Specifications

Parameter Specification
Brand / line Premisut Prime (polypropylene)
Material Polypropylene monofilament, uncoated, dyed blue
Absorption Non-absorbable; gradual encapsulation; wound support for over 3 months
Thread colour Blue (high visibility)
USP gauge / size USP 3/0 (metric EP 2)
Thread length 75 cm (1 thread per unit)
Needle shape ½ circle (1/2 circle)
Needle body Cylindrical
Tip type Trocar (Tapercut), HRT profile
Needle size 17 mm (HRT 17)
Configuration Single needle (1 × HRT 17)
Manufacturing quality Prime (premium range)
Sterilisation Ethylene oxide (EO)
Use Single-use, sterile. Do not re-sterilise
Indications Approximation and ligation of soft tissues; cardiovascular surgery, ophthalmology and neurosurgery
Commercial presentation Box of 12 units (individual sterile sachets)
Factory reference P732HRT1730
Reference Cahnos (SKU) AMP732HRT1730

The references 732HRT1730 (standard quality, SKU AM732HRT1730) and P732HRT1730 (Prime quality) share the same technical configuration of HRT17 needle, gauge 3/0, blue colour and 75 cm; the Prime version is distinguished by the premium finish of the needle.

4. Equivalences and Cross-References

Blue non-absorbable polypropylene monofilament is one of the most standardised permanent suture families on the market (“Prolene” type). There is no official equivalence table validated by the manufacturer that cross-references the reference P732HRT1730 with other brands; the following comparisons are functional, at category level, and not interchangeable 1:1 without prior technical validation against the datasheet and IFU of each manufacturer.

Manufacturer / Brand Family / Model Code / SKU Equivalence level Technical differences / Remarks
Premisut Prime (Cahnos) Prime Polypropylene – 1/2 circle trocar point HRT17, 3/0 blue, 75 cm P732HRT1730 / AMP732HRT1730 Exact reference equivalence (identical) Official reference of the analysed product.
Premisut (Cahnos) Standard Polypropylene – 1/2 circle trocar point HRT17, 3/0 blue, 75 cm 732HRT1730 / AM732HRT1730 Direct equivalent (same system) Same needle, gauge, colour and length; only the premium finish of the needle varies in the Prime version.
B. Braun (Aesculap) Premilene® – Polypropylene, 3/0, 75 cm, HRT17 needle trocar point (Tapercut) ½ circle C2090314 Comparable at category level (not interchangeable 1:1) Matches material, gauge, length (75 cm), ½ circle shape and 17 mm trocar point profile; reference confirmed in GUDID database (PREMILENE 3/0 (2) 75CM HRT17 (M)). Differ in needle finish and commercial presentation (box of 12 vs. 36); verify IFU.
Ethicon (J&J MedTech) PROLENE® – Polypropylene, 3/0, 75 cm, RB-1 needle ½ circle 17 mm 8872H Comparable at category level (not interchangeable 1:1) Matches material, gauge, colour, length and needle size (17 mm), but the RB-1 has a conical point (Taper Point) compared to the HRT with trocar point (Tapercut); different penetration profile for fibrous/calcified tissue.
Medtronic (Covidien) Surgipro™ II – Polypropylene with polyethylene, blue, 3/0, 75 cm, CV-25 needle ½ circle VP-760-X Comparable at category level (not interchangeable 1:1) Same gauge, colour and length; reference confirmed in authorised distributor catalogues with CV-25 conical point (Taper Point) needle. Material copolymer of polypropylene with polyethylene: different composition from the Premisut strand. Confirm needle profile by IFU.

Technical note: before substituting in a specification, protocol or operating theatre, verify one by one the exact gauge, thread length, needle shape and point (trocar vs. conical), needle size, material (pure polypropylene vs. copolymer), surface treatment and regulatory classification (CE/MDR) of the actual product from each manufacturer. Consult the technical department of Cahnos before using this information in a tender or direct substitution.

5. Selection tips and variants of interest

Trocar point (Tapercut): choose this configuration when the tissue presents some resistance or fibrosis (vascular, cardiovascular, fascia); the cutting point facilitates entry and the cylindrical body minimises trauma. For very friable tissues consider the conical point (Taper Point) variant from the same family.

Gauge: USP 3/0 (metric 2) is very versatile for vascular, cardiovascular and general soft tissue surgery. If greater strength is required, the same needle is available in gauges 2/0 and above in the range; for finer tissues, 4/0 (P732HRT1740) and 5/0 (P732HRT1750) with the same HRT17 needle.

Needle length: the 17 mm HRT is ideal for medium-depth surgical fields and delicate tissues. For deeper approaches, consider the HRT 25 (P732HRT2530) or HRT 36 (P732HRT3620) needles from the same line.

Double needle: for continuous suture techniques or anastomosis with two armed ends, the 2xHRT17 configuration is available in gauge 3/0 and 90 cm (P733HRT1730-2 / AMP733HRT1730-2), which avoids re-threading and optimises surgical time.

Prime range: the Premisut Prime line maintains the geometry of the standard version with improved needle finish; useful when the protocol demands premium penetration quality. Prior verification: always confirm the full reference (HRT17 needle, gauge 3/0 and length 75 cm) on the packaging before use in the operating theatre; check the integrity of the blister and the expiry date. Single-use product, not re-sterilisable.

Additional information

Material

Uncoated monofilament polypropylene

USP size

3/0 (metric EP 2)

Needle size

17 mm (HRT 17)

Absorption

Non-absorbable; gradual encapsulation; support > 3 months

Sterilisation

Ethylene oxide (EO)

Use

Single-use, not re-sterilisable

Presentation

Box of 12 units (individual sterile sachets)

Manufacturer reference

P732HRT1730

Quality

Prime (premium range)

Medida de aguja

HRT 17

Usp

3/0

Color

Blue

Medida de hilo

75 cm

Tipo de aguja

Cylindrical trocar tip

Forma de aguja

1/2 circle

Calidad sutura

Prime

Reviews

There are no reviews yet.

Be the first to review “Polypropylene suture Premisut Prime 1/2 circle, trocar point (Tapercut) HRT 17 mm – USP 3/0, blue, 75 cm | Box of 12 units (Ref. P732HRT1730)”

Your email address will not be published. Required fields are marked *