Description
1. Commercial Introduction
The polypropylene suture Premisut Prime is the reference choice for surgical departments, purchasing centres and tenders that need a non-absorbable thread with predictable behaviour, maximum tensile strength and minimal tissue reaction. This presentation in size USP 3/0 incorporates a ½ circle needle with cylindrical body and trocar point (Tapercut) of 25 mm (HRT 25 Prime profile) and a blue strand of 75 cm, a configuration especially valued in cardiovascular surgery, ophthalmology, neurosurgery and approximation of soft tissues. It is supplied sterile and ready for individual use in a box of 12 units with batch traceability.
2. Technical Explanation
Polypropylene is a linear synthetic polyolefin that is presented as uncoated monofilament: as it lacks interstices and wicking effect, it offers very smooth sliding through the tissue, does not favour bacterial adherence and minimises thread extrusion. It is not absorbed nor degraded by tissue enzymes: it is gradually encapsulated by fibrous connective tissue and maintains its tensile strength for more than three months, comfortably covering the critical healing phase.
The HRT 25 needle (½ circle, cylindrical body) with trocar or Tapercut point combines the firm penetration of a cutting point with a non-cutting body, allowing it to pass through slightly fibrous tissues, vascular adventitia or planes of certain resistance with less effort and without tearing the suture bed. The high-visibility blue colour facilitates identification of the thread and the knot on the surgical field. Sterilisation by ethylene oxide (EO); single-use product, not resterilisable.
3. Technical Specifications
| Parameter | Specification |
| Brand / line | Premisut Prime (polypropylene) |
| Material | Polypropylene monofilament, uncoated, dyed blue |
| Thread structure | Monofilament (fluted surface for high visibility) |
| Absorption | Non-absorbable; gradual encapsulation; wound support for over 3 months |
| USP gauge / size | USP 3/0 (EP metric 2); conforms to USP and European Pharmacopoeia gauges |
| Thread length | 75 cm |
| Thread colour | Identification blue |
| Needle shape | ½ circle (1/2 circle) |
| Needle body | Cylindrical |
| Tip type | Trocar (Tapercut), HRT profile |
| Needle size | 25 mm (HRT 25 Prime) |
| Configuration | Single needle (1 × HRT) |
| Manufacturing quality | Prime (premium range) |
| Sterilisation | Ethylene oxide (EO) – sterile |
| Use | Single-use, sterile. Do not re-sterilise |
| Indications | Approximation of soft tissues, ligatures, cardiovascular surgery, ophthalmology and neurosurgery |
| Commercial presentation | Box of 12 units (individual sterile sachets) |
| Factory reference | P732HRT2530 |
| Reference Cahnos (SKU) | AMP732HRT2530 |
HRT 25 family (½ circle, trocar/Tapercut point) in Prime quality:
| Needle profile | USP | Presentation | Reference |
| HRT 25 Prime | 2/0 | 75 cm | P732HRT2520 |
| HRT 25 Prime | 3/0 | 75 cm | P732HRT2530 |
| HRT 25 Prime | 4/0 | 75 cm | P732HRT2540 |
| 2xHRT 25 Prime | 3/0 | 2 × 90 cm | P733HRT2530-2 |
4. Equivalences and Cross-References
Blue non-absorbable monofilament polypropylene is one of the most standardised permanent suture families on the market (type “Prolene”). There is no official equivalence table validated by the manufacturer that cross-references P732HRT2530 with other brands; the following comparisons are functional, at category level, and not interchangeable 1:1 without prior technical validation against the technical data sheet and IFU of each manufacturer.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
| Premisut Prime (Cahnos) | Polypropylene HRT 25 Prime, USP 3/0, blue, 75 cm | P732HRT2530 / AMP732HRT2530 | Exact reference equivalence (identical) | Product analysed in this data sheet |
| Premisut (Cahnos) | Standard polypropylene HRT 25, USP 3/0, blue, 75 cm | 732HRT2530 / AM732HRT2530 | Direct equivalent (same system) | Same needle, size, colour and length; only the premium finish of the needle varies in the Prime version |
| Premisut Prime (Cahnos) | Polypropylene 2xHRT 25 Prime, USP 3/0, blue, 90 cm | P733HRT2530-2 / AMP733HRT2530-2 | Configuration equivalent within the same system | Same HRT 25 needle and size 3/0; changes to double needle and 90 cm of thread |
| Ethicon (J&J MedTech) | PROLENE® – blue polypropylene, 3/0, TAPERCUT point ½ circle | W8849 | Comparable at category level (not interchangeable 1:1) | Matches material, size and colour; W8849 confirmed as double needle CC-30 TAPERCUT of 31 mm with 90 cm of thread. Verify 25 mm needle and 75 cm presentation per IFU |
| B. Braun (Aesculap) | Premilene® – blue polypropylene, 3/0, HR needles ½ circle | C2090908 | Comparable at category level (not interchangeable 1:1) | Same material and size; C2090908 confirmed as 2xHR26 of 26 mm (cylindrical/conical HR point) versus HRT 25 mm (trocar Tapercut point). Confirm trocar point and presentation per IFU |
| Medtronic (Covidien) | Surgipro™ II – polypropylene copolymer, blue, 3/0, trocar point | SP / VP series – pending confirmation for HRT 25 | Comparable by category / pending confirmation | Polypropylene copolymer with polyethylene of different composition to the Premisut strand; confirm needle geometry and exact reference per IFU |
Mandatory technical note: there is no equivalence table validated by the manufacturer that cross-references this reference with other brands; comparisons with PROLENE®, Premilene® or Surgipro™ are functional, at category level, and must be confirmed against the technical data sheet or IFU of each manufacturer before use in tenders or direct substitution. Consult the technical department of Cahnos to validate any equivalence before substituting the product.
5. Selection tips and variants of interest
- Trocar point (Tapercut): choose this configuration when the tissue presents some resistance or fibrosis (vascular, cardiovascular, adventitia); the cutting point facilitates entry and the cylindrical body minimises trauma. For very friable tissues consider the conical point variant (Taperpoint) of the same Premisut family.
- USP size 3/0: very versatile for vascular, cardiovascular and general soft tissue surgery. If greater resistance is required, the same HRT 25 needle is available in USP 2/0 (P732HRT2520); for finer tissues, the USP 4/0 version (P732HRT2540).
- Double needle presentation: for continuous suture techniques and anastomosis with two armed ends without re-threading, consider the 2xHRT 25 version in 3/0 with 2 × 90 cm (P733HRT2530-2).
- Prime range: the Premisut Prime line maintains the geometry of the standard version with improved needle finish; useful when the protocol requires premium penetration quality.
- Prior verification: always confirm the complete reference (HRT 25 needle, size 3/0 and length 75 cm) on the packaging; check the integrity of the blister and the expiry date before each use and keep the batch number for traceability in the operating theatre. Single-use product, not resterilisable.





Reviews