Description
1. Commercial Introduction
The polypropylene suture PREMISUT is the reference choice for surgical departments, purchasing centres and tenders that require a non-absorbable thread with predictable behaviour, minimal tissue reaction and a needle that penetrates tissue with full control. This presentation in USP 3/0 gauge mounts a ½-circle needle with cylindrical body and Taperpoint conical point of 20 mm (HR20 profile) and a highly visible blue thread of 75 cm, designed for demanding procedures: cardiovascular surgery, ophthalmology, neurosurgery and the approximation and ligation of soft tissues.
Supplied sterile and ready for individual use in a box of 12 units with individual pouches and batch traceability, which facilitates hospital stock management and submission to public tenders. Available at Cahnos with the factory reference 732HR2030 (SKU AM732HR2030), kept unchanged.
2. Technical Explanation
Polypropylene is a synthetic linear polyolefin (propylene polymer, (C3H6)n) presented as an uncoated monofilament, dyed blue. Lacking interstices and wicking effect, it offers very smooth sliding through tissue, does not favour bacterial adherence or the formation of sinuses in wounds at risk of contamination and minimises thread extrusion. It is not absorbed or degraded by tissue enzymes: it is gradually encapsulated by fibrous connective tissue and maintains its tensile strength for more than three months, comfortably covering the critical healing phase.
The HR20 needle (½ circle, cylindrical body) with Taperpoint conical point separates and displaces tissue fibres without cutting them, making it ideal for soft, friable tissues and thin-walled vascular structures that require controlled penetration and minimal injury. The fluted finish of the needle improves grip in the needle holder and facilitates smooth, consistent delivery during knotting. Sterilisation by ethylene oxide (EO); single-use product, not re-sterilisable.
3. Technical Specifications
3.1. General characteristics
| Parameter | Specification |
| Brand / Line | PREMISUT (polypropylene, standard range) |
| Thread material | Polypropylene monofilament, uncoated, dyed blue (synthetic linear polyolefin, (C3H6)n) |
| Structure | Ribbed monofilament of a single filament, without coating or braiding |
| Absorption | Non-absorbable; gradual encapsulation; wound support for over 3 months |
| Gauge / USP size | USP 3/0 (EP metric 2); conforms to USP and European Pharmacopoeia gauges |
| Approximate thread diameter | 0.20 – 0.249 mm |
| Thread length | 75 cm (1 thread per sachet) |
| Thread colour | Grooved blue identifier, high visibility in the surgical field |
| Needle shape | ½ circular (1/2 circle), cylindrical body |
| Tip type | Conical Taperpoint, grooved (HR20 profile) |
| Needle size | 20 mm (HR20 profile) |
| Manufacturing quality | Standard (PREMISUT range; for premium finish see Prime variant) |
| Sterilisation | Ethylene oxide (EO) – sterile |
| Use | Single-use, sterile. Do not re-sterilise |
| Indications | Approximation of soft tissues, ligatures; cardiovascular surgery, ophthalmology and neurosurgery |
| Commercial presentation | Box of 12 units (sterile individual sachets); batch traceability |
| Storage | Below 30 °C, protected from moisture and direct sunlight |
| Factory reference | 732HR2030 |
| Reference Cahnos (SKU) | AM732HR2030 |
3.2. Gauge equivalence according to USP/EP standard (non-absorbable suture)
| USP size | Metric size | Approximate thread diameter |
| 3/0 | 2 | 0.20 – 0.249 mm |
3.3. PREMISUT HR20 family (½ circle, cylindrical body, conical Taperpoint point) and range variants
| Needle profile | USP size | Presentation | Reference |
| HR20 (standard) | 3/0 | 1 × 75 cm | 732HR2030 / AM732HR2030 (this product) |
| HR20 (standard) | 4/0 | 1 × 75 cm | 732HR2040 / AM732HR2040 |
| HR20 (Prime) | 3/0 | 1 × 75 cm | P732HR2030 / AMP732HR2030 |
| 2×HR20 (standard) | 3/0 | 2 × 90 cm | 733HR2030-2 / AM733HR2030-2 |
| 2×HR20 (Prime) | 3/0 | 2 × 90 cm | P733HR2030-2 / AMP733HR2030-2 |
4. Equivalences and Cross-References
Reference 732HR2030 corresponds to the official nomenclature of the PREMISUT range (HR20 profile, single 75 cm thread, USP 3/0 gauge, blue colour) and Cahnos markets it without altering characters. There is no official equivalence table validated by the manufacturer that cross-references this reference with other brands; the following comparisons are functional, at category level, and not interchangeable 1:1, and must be confirmed against the technical data sheet or IFU of each manufacturer before use in tenders or direct substitution.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
| Cahnos (PREMISUT Prime) | Polypropylene ½ circle HR20 Prime, USP 3/0, blue, 75 cm | P732HR2030 / AMP732HR2030 | Direct equivalent within the same family | Same measurements, material, gauge, colour and length; the needle finish changes to Prime range (improved penetration) |
| Ethicon (J&J MedTech) | PROLENE® – blue polypropylene monofilament, USP 3/0, 75 cm, SH taperpoint needle of ½ circle, 26 mm | 8832H | Comparable by category (not interchangeable 1:1) | Code verified in official Ethicon catalogue and authorised distribution: material, gauge, colour and length match; SH needle of 26 mm versus HR20 of 20 mm. Presentation in box of 36 units. |
| B. Braun (Aesculap) | Premilene® – blue polypropylene monofilament, USP 3/0 (EP 2), 75 cm, HR26 needle with round body ½ circle, 26 mm | C2090041 | Comparable by category (not interchangeable 1:1) | Code verified in distribution sources: same material, gauge and length; HR26 needle of 26 mm and non-fluted finish versus HR20 of 20 mm |
| Medtronic (Covidien) | Surgipro™ II – polypropylene/polyethylene copolymer, blue, USP 3/0, 30 inches (≈75 cm), GS-21 taper point needle, ½ circle, 37 mm | CP-422 | Comparable by category (not interchangeable 1:1) | Code verified in authorised distributors’ catalogue: same gauge, colour and length; copolymer material (not pure polypropylene) and GS-21 needle of 37 mm versus HR20 of 20 mm |
| DemeTECH | DemeLENE™ – blue polypropylene monofilament, USP 3/0, 75 cm, DSH needle of ½ circle round body | Consult official catalogue for 3/0 with 20 mm needle | Not verified | Sector family with equivalent material and gauge; confirm needle size and geometry, presentation and CE/MDR classification before substituting |
Mandatory technical note: there is no equivalence table validated by the manufacturer that cross-references reference 732HR2030 with other brands; comparisons with PROLENE®, Premilene® or Surgipro™ II are functional, at category level, and must be confirmed against the technical data sheet or IFU of each manufacturer before use in tenders. Consult the technical department of Cahnos to validate any equivalence before substituting the product.
5. Selection tips and variants of interest
Tissue to suture: the HR20 needle with fluted Taperpoint conical point is indicated for soft, vascular and friable tissues that require non-cutting penetration (cardiovascular surgery, ophthalmology, neurosurgery). For firm tissues or skin, consider trocar point profiles (HRT) from the same PREMISUT range.
Gauge: USP 3/0 (metric 2) offers an excellent balance between manageability and strength for vascular ligatures and soft tissue. If the protocol requires a smaller diameter, the same HR20 needle is available in 4/0 (ref. AM732HR2040); for greater strength, consider the HR25 (ref. AM732HR2530), HR30 (ref. AM732HR3030) or HR35 (ref. AM732HR3530) in gauge 3/0 and 75 cm.
Needle size: the HR20 of 20 mm is ideal for superficial and medium-thickness surgical fields, very common in ophthalmology and vascular microsurgery. If you need greater reach in deeper planes, the HR25 or HR35 are available in the same gauge; for smaller fields, consider the HR17 or HR15 from the same family.
Prime range and presentations: the PREMISUT Prime line (ref. AMP732HR2030) maintains the same needle geometry with a premium finish for improved penetration. If you prefer to make the most of each opening with two armed ends, consider the double-needle version 2×HR20 of 90 cm (ref. AM733HR2030-2).
Sterility verification: product sterile by ethylene oxide and single-use; check the integrity of the blister and the expiry date before each use and keep reference 732HR2030 and the batch number for traceability in the operating theatre. Store below 30 °C, away from moisture and direct sunlight. For special B2B conditions by volume or hospital supply agreements, contact the technical-commercial team of Cahnos.