Description
1. Product Presentation
The PREMISUT polypropylene suture is the reference choice for surgical departments, purchasing centres and tenders seeking a non-absorbable thread with predictable behaviour, maximum tensile strength and minimal tissue reaction. This presentation incorporates a double ½ circle conical point needle (Taperpoint) of 25 mm (2xHR25 profile), USP 4/0 gauge and a 90 cm fluted blue strand, a configuration especially valued in cardiovascular surgery, ophthalmology, neurosurgery and in the approximation and ligation of soft tissues.
It is supplied sterile, ready for immediate use, in a box of 12 units with individual envelopes and batch traceability. Available at Cahnos with factory reference 733HR2540-2 (SKU AM733HR2540-2), kept with characters unchanged.
2. Technical Explanation
Polypropylene is a synthetic linear polyolefin that is presented as a non-coated monofilament: lacking interstices and wick effect, it offers very smooth passage through tissue, does not promote bacterial adherence or sinus formation in wounds at risk of contamination, and minimises thread extrusion. Being non-absorbable, it is not degraded by tissue enzymes: it becomes gradually encapsulated by fibrous connective tissue and maintains its tensile strength for more than three months, comfortably covering the critical healing phase.
The HR needle (½ circle, cylindrical body) with Taperpoint conical point separates and displaces tissue fibres without cutting them, making it ideal for soft, friable tissues and thin-walled vascular structures that require controlled penetration and minimal injury. The double needle format (2x) allows continuous suture techniques and anastomosis with two armed ends, without re-threading, optimising surgical time. The high-visibility fluted blue strand facilitates identification of the thread and knot on the surgical field. Sterilisation by ethylene oxide (EO); single-use product, non-resterilisable.
3. Technical Specifications
3.1. General characteristics
| Parameter | Specification |
| Brand / line | PREMISUT (polypropylene, standard range) |
| Thread material | Polypropylene monofilament, uncoated, dyed blue |
| Thread structure | Monofilament (fluted surface for high visibility) |
| Absorption | Non-absorbable; gradual encapsulation; wound support for over 3 months |
| USP gauge / size | USP 4/0 (metric EP 1.5; diameter 0.15 – 0.199 mm); conforming to USP gauges and European Pharmacopoeia |
| Thread length | 90 cm (double-armed, 2 needles on the same thread) |
| Thread colour | Identification blue (fluted) |
| Needle shape | ½ circle (1/2 circle) |
| Needle body | Cylindrical |
| Tip type | Taperpoint conical, HR profile |
| Needle size | 25 mm (2 × HR 25) |
| Configuration | Double needle (2 × HR25) |
| Manufacturing quality | Normal (standard) |
| Sterilisation | Ethylene oxide (EO) – sterile |
| Use | Single-use, sterile. Do not re-sterilise |
| Indications | Approximation and ligation of soft tissues; cardiovascular surgery, ophthalmology and neurosurgery |
| Commercial presentation | Box of 12 units (sterile individual sachets); batch traceability |
| Factory reference | 733HR2540-2 |
| Reference Cahnos (SKU) | AM733HR2540-2 |
3.2. Gauge conformity (indicative according to USP Pharmacopoeia, synthetic non-absorbable suture)
| USP size | Metric size | Approximate thread diameter |
| 4/0 | 1.5 | 0.15 – 0.199 mm |
3.3. Premisut Family 2xHR25 (½ circle, cylindrical body, conical point) and range variants
| Needle profile | Presentation | Reference |
| 2xHR 25 (standard) | 2 × 90 cm, USP 4/0 (analysed product) | 733HR2540-2 / AM733HR2540-2 |
| 2xHR 25 (standard) | 2 × 90 cm, USP 3/0 | 733HR2530-2 / AM733HR2530-2 |
| 2xHR 25 (standard) | 2 × 90 cm, USP 2/0 | 733HR2520-2 / AM733HR2520-2 |
| 2xHR 25 (Prime) | 2 × 90 cm, USP 4/0 | P733HR2540-2 / AMP733HR2540-2 |
| HR 25 (standard, single needle) | 1 × 75 cm, USP 4/0 | 732HR2540 / AM732HR2540 |
4. Equivalences and Cross-References
The reference 733HR2540-2 corresponds to the official nomenclature of the PREMISUT range (2xHR25 profile, double conical point needle, USP 4/0 gauge, blue thread 90 cm). There is no official equivalence table validated by the manufacturer that cross-references this reference with other brands; comparisons between brands are functional, at category level, and not interchangeable 1:1, and must be confirmed against the technical data sheet or the IFU of each manufacturer before use in tenders or direct substitution.
| Manufacturer / Brand | Family / Model | Code / SKU | Equivalence level | Technical differences / Remarks |
| Cahnos (Premisut Prime) | Polypropylene 1/2 circle 2xHR25, USP 4/0, blue, 90 cm | P733HR2540-2 / AMP733HR2540-2 | Direct equivalent (same system) | Same needle geometry, gauge, colour and length; varies the premium finish of the needle (Prime version vs standard) |
| Cahnos (Premisut) | Polypropylene 1/2 circle 2xHR25, USP 4/0, blue, 90 cm | 733HR2540-2 / AM733HR2540-2 | Exact reference equivalence (current product) | Official reference of the analysed product |
| Cahnos (Premisut) | Polypropylene 1/2 circle 2xHR25, USP 3/0, blue, 90 cm | 733HR2530-2 / AM733HR2530-2 | Configuration equivalent (same system) | Same needle 2xHR25 and length; changes gauge to USP 3/0 |
| Ethicon (J&J MedTech) PROLENE® | Blue polypropylene monofilament, USP 4/0, 90 cm, double needle SH ½ circle conical point 26 mm | 8521H / 8521T | Comparable by category (not interchangeable 1:1) | Matches material, gauge, colour, double needle and length (90 cm); SH needle 26 mm vs HR 25 mm; presentation box of 36 units. Verified in authorised Ethicon distribution |
| DemeTECH DemeLENE™ | Polypropylene, USP 4/0, blue, double needle DSH ½ circle round body 26 mm, 90 cm | PM1094026C0P (DT-52x) | Comparable by category (not interchangeable 1:1) | Same gauge, colour and length; DSH needle 26 mm round body, without fluted channel. Verified in technical data sheet of authorised distributor |
| B. Braun Premilene® | Blue polypropylene, USP 4/0 (metric 1.5), 90 cm, double needle 2xHR26 CV conical point | C2090907 (candidate in series C2090xxx) | Comparable by category / pending confirmation | Confirms the range in sequence C2090908 (3/0 HR26); for 4/0 90 cm 2xHR26 CV verify the exact code in the official B. Braun catalogue before substituting |
| B. Braun Optilene® | Polypropylene-polyethylene copolymer, blue, USP 4/0, 90 cm, double needle HR26 | C3090907 | Comparable by category (not interchangeable 1:1) | Copolymer composition vs pure polypropylene; HR26 needle 26 mm. Confirm IFU |
Mandatory technical note: there is no equivalence table validated by the manufacturer for the PREMISUT line against other brands; comparisons with PROLENE®, DemeLENE™, Premilene® or Optilene® are functional, at category level, and must be confirmed against the technical data sheet or IFU of each manufacturer before use in tenders or direct substitution. Consult the technical department at Cahnos to validate any equivalence.
5. Selection tips and variants of interest
Taper point (Taperpoint): choose this configuration for soft, friable or delicate tissues (parenchyma, fat, thin-walled vascular structures); the cylindrical body and conical tip minimise tissue trauma. For tissues with some fibrosis or resistance, consider the trocar point (Tapercut) variant from the same family (e.g. AM733HRT2540-2 in 4/0).
USP gauge 4/0: fine thread with high manageability, widely used in cardiovascular surgery, ophthalmology and delicate soft tissue. If greater strength is required, the same 2xHR25 needle is available in gauges 3/0 (AM733HR2530-2) and 2/0 (AM733HR2520-2).
Needle length: the 25 mm HR is ideal for superficial and medium-thickness planes; if greater reach is needed in deep fields, consider the 35 mm or 48 mm HR from the same range. At Cahnos, the single-needle version of 75 cm (AM732HR2540) and the premium Prime range (AMP733HR2540-2) are also available, as well as the VisiBlack variant with black needle (AMP733HR2540-2VB) for extreme visibility.
Prior verification: always confirm the full reference (2xHR25 needle, USP gauge 4/0 and 90 cm length) on the packaging; check the integrity of the blister and the expiry date before each use and keep the batch number for traceability in the operating theatre. Single-use product, not re-sterilisable. Store below 30 °C, away from moisture and direct sunlight.