Description
1. Product Presentation
The Polypropylene Suture PREMISUT is the reference choice for surgical services, purchasing centres and tenders that need a non-absorbable suture with predictable behaviour, high tensile strength and minimal tissue reaction. This presentation in USP 3/0 gauge incorporates a ½ circle needle with cylindrical body and Taperpoint conical point of 17 mm (HR17 profile) and a blue strand of 75 cm: a classic and versatile configuration, highly valued in cardiovascular surgery, ophthalmology, neurosurgery and in the approximation and ligation of soft tissues.
It is supplied sterile, ready for individual use, in a box of 12 units with individual envelopes and batch traceability. Available at Cahnos with the factory reference 732HR1730 (SKU AM732HR1730), with characters unchanged.
2. Technical Explanation
Polypropylene is a linear synthetic polyolefin that is presented as an uncoated monofilament: as it lacks interstices and wicking effect, it offers very smooth sliding through tissue, does not favour bacterial adherence and minimises thread extrusion. As it is not absorbable, it is not degraded by tissue enzymes: it is gradually encapsulated by fibrous connective tissue and maintains its tensile strength for more than three months, comfortably covering the critical healing phase.
The HR17 needle (½ circle, cylindrical body) with Taperpoint conical point separates and displaces tissue fibres without cutting them, which makes it especially suitable for soft, friable tissues and thin-walled vascular structures that require controlled penetration and minimal injury. The USP 3/0 gauge (metric EP 2) offers an excellent balance between strength and handling for medium-tension tissues. The blue strand ensures optimal visibility over the surgical field. Sterilisation by ethylene oxide (EO); single-use product, not re-sterilisable.
3. Technical Specifications
| Parameter | Specification |
| Brand / Line | PREMISUT (polypropylene, standard range) |
| Thread material | Polypropylene monofilament, uncoated, dyed blue |
| Thread structure | Monofilament of a single filament, without coating or braiding |
| Absorption | Non-absorbable; gradual encapsulation; wound support for over 3 months |
| Gauge / USP size | USP 3/0 (EP metric 2); conforms to USP and European Pharmacopoeia gauges |
| Thread diameter | 0.200 – 0.249 mm (indicative, according to USP Pharmacopoeia, non-absorbable suture) |
| Thread length | 75 cm (1 thread per sachet) |
| Thread colour | Identifying blue, high visibility on the surgical field |
| Needle shape | ½ circle (1/2 circle) |
| Needle body | Cylindrical |
| Tip type | Conical Taperpoint, HR17 profile |
| Needle size | 17 mm (HR17 profile) |
| Configuration | Single needle (1 × HR17) |
| Manufacturing quality | Normal (standard) |
| Sterilisation | Ethylene oxide (EO) – sterile |
| Use | Single-use, sterile. Do not re-sterilise |
| Indications | Approximation and ligation of soft tissues; cardiovascular surgery, ophthalmology and neurosurgery |
| Commercial presentation | Box of 12 units (sterile individual sachets); batch traceability |
| Factory reference | 732HR1730 |
| Reference Cahnos (SKU) | AM732HR1730 |
| Storage | Below 30 °C, protected from moisture and direct sunlight |
HR17 family (½ circle, cylindrical body, conical point) within the PREMISUT range:
| USP size | Presentation | Quality | Reference Cahnos |
| 3/0 | 1 × 75 cm | Standard | AM732HR1730 (product analysed) |
| 4/0 | 1 × 75 cm | Standard | AM732HR1740 |
| 5/0 | 1 × 75 cm | Standard | AM732HR1750 |
| 3/0 | 1 × 75 cm | Prime (premium needle finish) | AMP732HR1730 |
4. Equivalences and Cross-References
Blue non-absorbable polypropylene monofilament is one of the most standardised permanent suture families on the market (type ‘Prolene’). There is no official equivalence table validated by the manufacturer that cross-references 732HR1730 with other brands; the following comparisons are functional, at category level, and not interchangeable 1:1 without prior technical validation against the technical data sheet and IFU of each manufacturer.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
| PREMISUT (Cahnos) | Prime Polypropylene – ½ circle conical point HR17, 3/0 blue, 75 cm | P732HR1730 / AMP732HR1730 | Direct equivalence (same system) | Same HR17 needle, gauge, colour and length; only the premium finish of the needle varies. |
| PREMISUT (Cahnos) | Polypropylene HR17, USP 3/0, blue, 75 cm – trocar point (Tapercut) | 732HRT1730 / AM732HRT1730 | Comparable by category (not interchangeable 1:1) | Same gauge, colour, length and 17 mm needle; the point differs: trocar (Tapercut) versus conical (Taperpoint). Different penetration profile for fibrous tissue. |
| Ethicon (Johnson & Johnson MedTech) | PROLENE® – blue polypropylene monofilament, 3-0, 75 cm, RB-1 needle of 17 mm, ½ circle, conical point | 8872H (verified in authorised distributors) | Comparable at category level (not interchangeable 1:1) | Material, gauge, colour, length (75 cm), needle size (17 mm), ½ circle arc and conical point (Taper Point) match. Needle finish and commercial presentation differ; verify IFU. |
| B. Braun (Aesculap) | Premilene® – blue polypropylene, 3/0 (EP 2), 75 cm, HRT 17 needle, ½ circle, trocar point | C2090314 (GUDID: PREMILENE 3/0 (2) 75CM HRT17 (M)) | Comparable at category level (not interchangeable 1:1) | Material, gauge, 75 cm length and 17 mm needle in ½ circle match; the point differs: trocar (Tapercut) versus conical, and the commercial presentation. Verify IFU. |
| Medtronic / Covidien | Surgipro™ II – polypropylene copolymer with polyethylene, blue, 3/0, 75 cm, CV-25 needle, ½ circle, conical point | VP-760-X (verified in authorised distributors) | Comparable at category level (not interchangeable 1:1) | Same gauge, colour and length; CV-25 needle with conical point (Taper Point). Copolymer material (polypropylene with polyethylene), composition different from the PREMISUT strand. |
Mandatory technical note: there is no equivalence table validated by the manufacturer that cross-references this reference with other brands; before substituting in tender, protocol or operating theatre, verify one by one the exact gauge, thread length, needle shape and point (conical vs. trocar), needle size, material (pure polypropylene vs. copolymer) and regulatory classification (CE/MDR) of the actual product of each manufacturer. Consult the technical department of Cahnos before using this information in tendering or direct substitution.
5. Selection tips and variants of interest
- Tissue to suture: the HR17 needle with Taperpoint conical point is indicated for soft, friable tissues and thin-walled vascular structures where the aim is to separate fibres without cutting them (cardiovascular surgery, ophthalmology, neurosurgery). For somewhat more fibrous tissues or vascular adventitia, consider the trocar point (Tapercut) variant of the same family (AM732HRT1730).
- Gauge: USP 3/0 (metric 2) offers an excellent balance between strength and handling for soft tissues of medium tension and ligatures. If finer is required, the same HR17 needle is available in 4/0 (AM732HR1740) and 5/0 (AM732HR1750).
- Needle size: the 17 mm HR is ideal for surgical fields of medium depth and delicate tissues. For deeper approaches, the HR20, HR25 or HR35 needles are available within the PREMISUT range.
- Prime range: the PREMISUT Prime line (AMP732HR1730) maintains the same technical configuration with improved needle finish and superior penetration; useful when the protocol requires premium quality.
- Sterility verification: sterile product by ethylene oxide and single-use; check the integrity of the blister and the expiry date before each use and keep the reference 732HR1730 and the batch number for traceability in the operating theatre. Store below 30 °C, away from moisture and direct sunlight.
For special B2B conditions based on volume, hospital supply agreements or equivalents from other manufacturers, contact the technical-commercial team of Cahnos.