1. Product Presentation
The polyester suture Premisut Prime with a ½ circle HR30 needle is the reference choice for the professional seeking a non-absorbable thread with a soft feel, high tensile strength and minimal tissue drag. Its cylindrical-bodied needle with a 30 mm conical point (taperpoint) passes through tissue by separating the fibres without cutting them, which is particularly indicated for delicate planes such as ophthalmology and neurosurgery, as well as for the approximation of soft tissues and ligatures. It is supplied sterile, ready for use, in a box of 12 units.
2. Technical explanation
It is a braided multifilament polyester suture (polyethylene terephthalate) coated with silicone. The silicone coating provides a smooth outer surface that slides gently through tissue, reduces the sawing effect when tying knots and improves handling and knot security. Being non-absorbable, it does not lose mass or strength through hydrolysis: gradual fibrous encapsulation occurs and the wound retains mechanical support beyond three months. The ½ circle conical-point needle (HR30, 30 mm) facilitates atraumatic and controlled passes, with excellent tensile strength. Sterilisation by ethylene oxide (EO).
3. Technical Specifications
| Parameter | Specification |
| Material | Braided multifilament polyester (polyethylene terephthalate) |
| Coating | Silicone (optimal sliding and handling) |
| Absorption | Non-absorbable – gradual encapsulation, support > 3 months |
| Gauge | USP 3/0 (metric 2.0) |
| Thread length | 75 cm |
| Needle shape | ½ circle (1/2 circular) |
| Needle body | Cylindrical |
| Needle tip | Conical – taperpoint (atraumatic) |
| Needle size | 30 mm (HR30) |
| Thread colour | Green (grooved) |
| Sterilisation | Ethylene oxide (EO) |
| Indications | Soft tissue approximation, ligatures, ophthalmology, neurosurgery |
| Presentation | Box of 12 units |
| Reference Premisut | P852HR3030 (Premium/Prime range) |
| SKU Cahnos | AMP852HR3030 |
4. Equivalences and Cross-References
There is no official equivalence table validated by the manufacturer for this exact configuration (½ circle 30 mm conical-point needle + gauge 3/0 + 75 cm + green). The cross-references indicated below are category-level comparisons and should not be considered interchangeable 1:1 without prior technical verification.
| Manufacturer / Brand | Family / Model | Indicative code | Equivalence level | Technical differences |
| Ethicon (Johnson & Johnson MedTech) | ETHIBOND EXCEL™ (braided polyester, green) | W6832 (USP 3/0, 75 cm, SH needle ½ circle conical point 26 mm) | Comparable at category level | Polybutylate coating (not silicone); 26 mm needle versus 30 mm; verify actual radius, point and gauge before substituting. |
| Medtronic (Covidien) | Surgidac™ / Ti-Cron™ (non-absorbable braided polyester) | Consult official catalogue for gauge and needle | Comparable at category level | Same base material (polyethylene terephthalate) and indications including ophthalmic and neural tissue; confirm coating and needle geometry by reference. |
| Cahnos – same family Premisut | Premisut Prime polyester, same HR30 needle | AMP852HR3020 (2/0) / AMP852HR3010 (0) | Same family and needle; gauge changes | Same thread, needle and colour; choose gauge according to clinical need |
| Cahnos – Premisut other geometries | HR26 and double needle | P852HR2630 (HR26, 3/0) / P852HR2020-2 (2xHR20, 2/0) | Similar by category | Different needle radius or size; not 1:1 interchangeable with single HR30 needle |
Pending confirmation: for use in tendering or substitution of another manufacturer’s reference, consult the technical department before formalising the change.
5. Selection tips and variants of interest
If you need the same HR30 needle with a thicker gauge, request the USP 2/0 variant (AMP852HR3020) or USP 0 (AMP852HR3010), both in green and 75 cm. For continuous suturing with a double needle in a ½ circle radius, the family offers reference P852HR2020-2 (2xHR20, USP 2/0, green). Always verify the compatibility of the needle (½ radius, conical point, 30 mm) with the needle holder and the suturing technique (interrupted or continuous) used in your department. As a non-absorbable thread, it does not require replacement due to loss of strength; its removal, if required, is surgical. Confirm your centre’s protocol.